# REFORM-3D: A Representation-Centric Evaluation Framework for 3D Medical Vision Foundation Models

REFORM-3D evaluates frozen 3D medical encoders by what their features actually encode

Maregu Assefa, Muzammal Naseer, Divya Velayudhan, Gedamu Alemu Kumie, Naoufel Werghi · arXiv · 2026-11-6

- **Problem** Downstream task scores mix encoder quality with adaptation choices, so they cannot show whether 3D medical features are organized by anatomy. Spacing changes in volumetric scans can also shift features even when the anatomy stays fixed.
- **Method** REFORM-3D tests frozen 3D encoders directly on three questions: stability under spacing changes, cross-modal organ retrieval, and transfer from limited labeled support. The authors pretrain Med3DINO under three geometric policies, which differ only in how volumes are presented.
- **Results** Voxel-relative sampling gives lower embedding drift, while spacing-aware resampling scores higher on anatomical transfer. On HECKTOR CT-PET retrieval, Med3DINO-SA reaches 53.73 mAP compared with 52.21 for REL.

## Why downstream scores hide the encoder

Most 3D medical foundation models are judged by how well they perform after adaptation to a downstream task. So a model can look strong without showing that its features are organized by anatomy rather than by narrower cues that happen to predict the labels. The gap matters most for DINO-style encoders, because downstream scores alone don't fully characterize their dense and local features.

The problem is sharper in 3D, because acquisition geometry directly changes the evidence a volumetric encoder receives. Figure 1 isolates this effect by resampling one CT volume to 1.0×1.0×1.0 mm, 1.0×1.0×3.0 mm and 1.0×1.0×5.0 mm while the anatomy stays fixed. Those variants span reference isotropic spacing, moderate anisotropy, and higher anisotropy.

The same figure shows that low drift alone doesn't establish robustness.

That setup doesn't reveal whether sensitivity comes from the frozen representation or from the adapted task pipeline. REFORM-3D therefore evaluates frozen features directly, with each claim scoped to its dataset, task and protocol.

## Three probes on frozen features

REFORM-3D keeps the encoder frozen and tests its features directly, instead of fitting a task head first. Figure 2 places the three modules side by side, from spacing variants of one scan to organ retrieval and limited-label transfer.

![Figure 2: Overview of REFORM-3D Framework. The framework assesses frozen 3D representa- tions along three axes: (a) Acquisition Robustness, using controlled sa…](https://refivu.com/papers/09c21d02-07bb-40da-a845-16862c6f9fbb/figures/figure-10e2d735266c016d3935972e7105351f.png?thumb=512)

**Figure 2** :Overview of REFORM-3D Framework. The framework assesses frozen 3D representa- tions along three axes: (a) Acquisition Robustness, using controlled same-scan spacing perturbations to measure stability, structural preservation (CKA), and transfer; (b) Cross-Modal Anatomical Align- ment, evaluating bidirectional cross-modal retrieval; and (c) Anatomical Transfer from limited labels under case-disjoint evaluation. Plots illustrate main trends across models and metrics.

[Original paper](https://arxiv.org/abs/2611.10062v1) · [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/) · Maregu Assefa, Muzammal Naseer, Divya Velayudhan, Gedamu Alemu Kumie, Naoufel Werghi · REFORM-3D: A Representation-Centric Evaluation Framework for 3D Medical Vision Foundation Models · Original paper figure · Extracted the figure area from page 4 of the original PDF.

For acquisition robustness, each scan is resampled to a target spacing s, and the embedding comes from that resampled volume. Within-scan drift is one minus the cosine similarity between the embeddings of the same scan at two spacings, so a lower value means the embedding moved less. CKA is computed over the same scans to check whether the cohort-level feature organization is preserved.

Drift alone doesn't show whether that cohort-level geometry survives, so the framework pairs it with CKA. Semantic transfer trains a classifier on features at spacing a and tests it on features at spacing b. The standardizer and classifier are fitted only at the source spacing, and then applied unchanged at the target spacing.

Cross-modal alignment ranks candidates from the opposite modality by cosine similarity for each query. Each query's average precision is averaged within a direction, and the two directions are then averaged equally. The bidirectional mean mAP↔ keeps CT→MR and MR→CT equally weighted, so neither direction dominates. Top-1 and Top-5 accuracy are reported alongside mAP.

These metrics test ranking of same-organ matches above competing organs, not voxel-level alignment.

For anatomical transfer, two support samples per organ and modality fit the classifier. Queries come from cases disjoint from all support cases, so the test doesn't reuse patients seen during fitting. Balanced accuracy averages recall over the evaluated organs, so each organ carries the same weight regardless of how many queries it has.

## Three geometric pretraining policies for Med3DINO

Med3DINO adapts 3DINO to volumetric medical images with a ViT-L/16 backbone, DINO, iBOT and KoLeo objectives. Its pretraining corpus holds 62,638 unlabeled volumes, also written 62.6K, spanning CT, MR, PET, CTA and CBCT. The authors fix the corpus, initialization, architecture, objective and non-geometric augmentations across the three variants.

The three variants differ only in geometric policy, so each one reads as a complete policy rather than a single-parameter ablation. ISO resamples each volume to 1.5×1.5×1.5 mm before voxel-relative cropping, which removes the native anisotropy from the input. SA uses global through-plane physical scale range 120 to 280 mm and local crops of 40 to 100 mm.

SA gates rotations by an anisotropy threshold of 2.0, so cross-plane rotations are skipped for highly anisotropic data. REL applies rotations without an anisotropy gate.

Other pretrained encoders serve only as contextual baselines, so causal claims about geometric pretraining rest on the ISO, REL and SA triplet. This design lets the authors attribute differences to the geometric policy, because the other settings don't change between variants.

## Acquisition stability results

REL keeps embeddings most stable under spacing change, as measured by within-scan cosine drift on CLS features. Across the four acquisition datasets shown in the main text, REL has lower CLS drift than SA. Averaged equally across the five acquisition datasets, REL also has lower mean drift at both target severities. The controlled CT and CTA targets are 1.0, 1.0, 3.0 mm and 1.0, 1.0, 5.0 mm, with in-plane spacing held fixed.

Drift tracks how far one scan's embedding moves, so it doesn't show whether cohort-level feature geometry is preserved.

REL also reaches higher mean CKA than SA at both target severities, so its feature-space organization holds up better on average. In the pretraining-unseen analysis, CKA favors REL on KiTS23 and SA on TS-MR. It favors REL on ImageCAS and changes direction on JHU-Stroke, so the transfer advantage stays dataset-specific. Transfer trains a classifier at the source spacing and applies it unchanged at the target spacing, which tests label recoverability rather than embedding movement.

Low drift alone doesn't establish robustness, because label-relevant information must also stay usable. REL's lower drift therefore doesn't settle whether its features carry the same semantics as SA's. On the other dataset, the drift comparison shows no supported separation. The acquisition tests use controlled resampling, which doesn't reproduce the full variability of clinical acquisition.

The REL and SA findings also come from a single architecture and self-supervised objective.

## Retrieval and organ transfer results

The retrieval question asks whether features that stay stable also keep organ identity matchable across CT and MR. SA leads on four of seven organs in the reversed MMWHS direction, but REL's larger gains on the other organs set the aggregate.

On the pretraining-unseen datasets, MMWHS and AMOS22, SA ranks first for cross-modal mAP, Top-1 and probe BA. Its mean ranks for ISO/REL/SA are 3.0/2.0/1.0 on each of those three metrics. Each SA–REL outcome is supported on both eligible datasets, with Bonferroni-adjusted intervals that must exclude zero.

On the HECKTOR-2025 CT–PET extension, SA reaches higher mean mAP and Top-1 than REL and ISO for both feature types. For CLS, SA scores 53.73 mAP and 54.17 Top-1, compared with 52.21 mAP and 49.83 Top-1 for REL. The random-ranking reference on the reported scale is 51.07 mAP and 49.83 Top-1. Because same-patient targets are excluded, retrieval can't succeed by matching a patient's registered CT/PET pair.

The two questions split across policies, since REL lowers mean drift and raises mean CKA at both target severities. SA instead favors semantic transfer on AbdomenAtlas, KiTS23, and TS-MR at both severities. On KiTS23 CKA favors REL, while SA leads on TS-MR. In this comparison, REL keeps embeddings most stable, while SA keeps organ identity most recoverable.

## Downstream segmentation as a secondary check

Segmentation is the downstream check that REFORM-3D runs alongside its representation probes. Med3DINO keeps the pretrained encoder frozen and trains a ViTAdapterUNETR decoder on each dataset's labeled training set. The decoder follows 3DINO and trains with AdamW at an initial learning rate of 10−4. A warmup-cosine schedule runs for 100 epochs, and early stopping triggers after 30 validation evaluations without improvement.

The checkpoint with the highest validation Dice goes to the test split, which runs with sliding-window inference. Dice is averaged over test scans, and HD95 aggregation drops non-finite per-scan values. ISO achieves lower HD95 on AMOS-MR than SA does. Among external comparisons, 3DINO achieves higher BTCV Dice than the Med3DINO variants.

These segmentation results agree with the retrieval and probe results, which also favor SA. Decoder choice, supervision and optimization still shape these scores, so segmentation can't replace the representation probes.

## Where the REFORM-3D results stop applying

It doesn't establish broader invariance, and it doesn't replace downstream evaluation.

The REL and SA findings come from one architecture and one self-supervised objective. Med3DINO uses the DINO, iBOT and KoLeo objective on a ViT-L/16 backbone, so the policy comparison hasn't been tested under other pretraining recipes. Establishing generality would require matched geometric-policy comparisons under other recipes.

Retrieval crops keep the surrounding image content, so the scores reflect context-assisted organ retrieval. Those scores don't isolate purely organ-intrinsic features. The CHAOS liver pairing and the HECKTOR CT–PET extension follow their own declared label and modality definitions. These surfaces don't test voxel-level registration or general modality invariance.

Anatomical transfer uses two support samples per modality for every evaluated organ. Support cases are chosen before the query pool is built, and all records from those cases are excluded from queries.

## Paper info

- **Authors**: Maregu Assefa, Muzammal Naseer, Divya Velayudhan, Gedamu Alemu Kumie, Naoufel Werghi
- **Venue**: arXiv · Preprint
- **First published**: 2026-11-6
- **Added**: 2026-11-10
- **Updated**: 2026-11-6
- **Version**: v1
- **arXiv**: 2611.10062
- **Category**: cs.CV
- **Original paper terms**: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/)
- **What we show**: Paper info, commentary and permitted figures from the original paper

[Original paper ↗](https://arxiv.org/abs/2611.10062v1) · [PDF ↗](https://arxiv.org/pdf/2611.10062v1)

AI commentary is a separate explanation from the original paper and may contain errors. The original paper and figures follow each source's terms of use and any rights noted separately.

## Abstract

Evaluation of 3D medical foundation models is typically dominated by downstream task scores, which entangle representation quality with adaptation choices. This is especially critical in volumetric imaging, where spacing and anisotropy can substantially alter image statistics while the anatomy itself remains unchanged. We therefore introduce \\textbf{REFORM-3D}, a \\textbf{R}epresentation-centric \\textbf{E}valuation \\textbf{F}ramew\\textbf{OR}k for benchmarking frozen 3D medical vision foundation \\textbf{M}odels across three questions: Acquisition Robustness, asking whether features remain stable when spacing varies while anatomy is fixed; Cross-Modal Anatomical Alignment, asking whether labeled anatomical structures remain recoverable across modalities under balanced bidirectional retrieval; and Anatomical Transfer, asking whether organ identity remains recoverable from limited labeled support under case-disjoint evaluation. These are also pretraining questions, because what a 3D encoder learns depends on how volumes are geometrically presented during self-supervised pretraining. We further introduce Med3DINO encoder family, pretrained on $62.6$K unlabeled MR, CT, PET, CTA, and CBCT volumes under three explicit geometric assumptions: isotropic normalization, voxel-relative sampling, and spacing-aware resampling. Across Med3DINO and heterogeneous external encoders, REFORM-3D reveals module-specific strengths rather than a single model ordering. Within the controlled Med3DINO comparison, voxel-relative sampling yields lower embedding drift, whereas spacing-aware resampling favors anatomical transfer; semantic-transfer advantages depend on the dataset and feature type. Project link: \\href{https://endarzboy.github.io/reform3d-website/}{\\highlightLR{REFORM-3D}}.

## Quote from the paper

Maregu Assefa, Muzammal Naseer, Divya Velayudhan, Gedamu Alemu Kumie, Naoufel Werghi (2026). REFORM-3D: A Representation-Centric Evaluation Framework for 3D Medical Vision Foundation Models. arXiv:2611.10062v1. https://arxiv.org/abs/2611.10062v1

**BibTeX**

```
@misc{assefa2026reform,
  title = {{REFORM-3D: A Representation-Centric Evaluation Framework for 3D Medical Vision Foundation Models}},
  author = {Maregu Assefa and Muzammal Naseer and Divya Velayudhan and Gedamu Alemu Kumie and Naoufel Werghi},
  year = {2026},
  eprint = {2611.10062},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.10062v1}
}
```

## Other paper commentary

- [ESTRA: Enabling Extreme Attention Sparsity for Training-Free Video Diffusion Acceleration](https://refivu.com/en/papers/6a74d9dd-6805-4d9a-a7f5-24ad9bf9ed98-estra-enabling-extreme-attention-sparsity-for-training-free.md)
- [Adapting Frozen Promptable Segmenters to User-Defined Taxonomies via Few-Shot Proposal Learning](https://refivu.com/en/papers/ffa6a892-7994-4958-9d38-c9539bf59b52-adapting-frozen-promptable-segmenters-to-user-defined.md)
- [SSD: Single Shot MultiBox Detector](https://refivu.com/en/papers/1889995f-3f80-4a7d-b734-c549e845a707-ssd-single-shot-multibox-detector.md)
- [BinsFormer: Revisiting Adaptive Bins for Monocular Depth Estimation](https://refivu.com/en/papers/7fc81cb2-3782-4326-9ffa-5af4ea6fe25b-binsformer-revisiting-adaptive-bins-for-monocular-depth.md)
- [Unifying Flow, Stereo and Depth Estimation](https://refivu.com/en/papers/a17a6b8c-5864-4598-9183-8a1c09180428-unifying-flow-stereo-and-depth-estimation.md)
- [Deep Gradient Learning for Efficient Camouflaged Object Detection](https://refivu.com/en/papers/ab2734b0-aadf-4a7a-9878-ec87828236f4-deep-gradient-learning-for-efficient-camouflaged-object.md)
- [fNIRSAtlas: A Large-Scale Benchmark for Functional Near-Infrared Spectroscopy Classification](https://refivu.com/en/papers/737a86b6-67d3-493d-ba06-3a82812f1ecd-fnirsatlas-a-large-scale-benchmark-for-functional-near.md)
- [Done Is Not Correct: Measuring Silent Failures and Self-Verification Calibration When LLM Agents Take CAD Actions](https://refivu.com/en/papers/55faa4f4-f2a8-47b8-b8cf-58bed596872c-done-is-not-correct-measuring-silent-failures-and.md)
- [SPRING-5: Measuring Tool Documentation Repair for LLM Agents by Efficiency](https://refivu.com/en/papers/d2846765-4203-48b2-8e62-5757c120b7fc-spring-5-measuring-tool-documentation-repair-for-llm.md)
- [Prove What You Can: Hybrid Neurosymbolic Reasoning for Logical Natural Language Inference](https://refivu.com/en/papers/7ace6c85-d1e6-4bd6-8cac-47f06ddabf88-prove-what-you-can-hybrid-neurosymbolic-reasoning-for.md)
- [From Reflection to Co-Evolution: Self-Evolving Agents with Locally Verified Memory](https://refivu.com/en/papers/cbbe388f-f036-4542-8fc6-f6b3901438a8-from-reflection-to-co-evolution-self-evolving-agents.md)
- [Quantitative Assessment of Crystal Structure Prediction](https://refivu.com/en/papers/a567aa7e-a18e-4315-b76a-1436ba6888e2-quantitative-assessment-of-crystal-structure-prediction.md)

## Terms in this paper

- [balanced accuracy](https://refivu.com/en/terms/bc9870524813-balanced-accuracy)

---

AI-written text can contain mistakes. [Refivu](https://refivu.com/en/papers/09c21d02-07bb-40da-a845-16862c6f9fbb-reform-3d-a-representation-centric-evaluation-framework-for)
