# From Natural Images to Medical Scans: Transferability of Diffusion Models for Medical Image Generation

Natural-image pretraining helps diffusion models generate medical scans better than training from scratch

Efthymios Georgiou, Ioannis Kakogeorgiou, Sarah Brüningk · arXiv · 2026-11-3

- **Problem** Medical diffusion models train their denoisers from scratch, so natural-image transfer has rarely been tested. Denoisers are treated as an implementation detail, leaving the benefit of pretraining unknown.
- **Method** The authors start pixel and latent denoisers from ImageNet weights instead of random initialisation. They then train the denoisers on RadImageNet and BraTS slices using the model's own recipe.
- **Results** Natural-image initialisation lowers gFID in both pixel and latent diffusion, by 21-34% relative in pixel space against 14% in latent space. On RadImageNet, JiT-B/16 gFID fell to 36.48, compared to 55.50 from random initialisation.

## Why medical diffusion models rarely reuse natural denoisers

Medical imaging leans heavily on natural-image pretraining, but generative modelling has seen far less of it. Most medical diffusion models train their denoiser from scratch, and the few that reuse weights mostly fine-tune text-to-image models. Where natural-image parts are reused, they are usually tokenisers, so the denoiser is treated as an implementation detail.

Two questions follow: does a natural-image denoiser help medical generation, and which part of its pretrained state carries the benefit. The answer depends on the paradigm, because a latent model gets part of its prior from the tokeniser. A pixel model gets its prior only from the denoiser, so transfer there is the whole story. The paper studies JiT as its pixel denoiser and LDiT-XL with three tokenisers as its latent denoiser.

Its headline results point the same way, with 21-34% relative gFID gains in pixel space against 14% in latent space.

## The starting-point comparison

The core idea is to start a medical denoiser from ImageNet weights and then train it on medical slices with the model's own recipe. The authors compare three starts: IN loads the full ImageNet denoiser weights, while RANDOM keeps each model's default random initialisation.

The pixel denoiser is JiT, a plain transformer that denoises large pixel patches with an x-prediction objective. Here JiT uses 16×16 patches, and its three sizes B/16, L/16 and H/16 have 12, 24 and 32 layers. The latent models pair LDiT-XL with one of three tokenisers: SDVAE, a natural-image autoencoder, VAVAE, a natural-image VAE aligned with DINOv2, and MedVAE, the medical baseline.

VAVAE compresses space more heavily, so the authors pair it with LDiT-XL/1, a latent patch size of 1. SDVAE and MedVAE, with lower compression, go with LDiT-XL/2, a patch size of 2.

The denoisers are trained on the RadImageNet and BraTS slices at 256×256 resolution. The authors set cfg to 1.0 throughout, so that transfer effects aren't confounded by guidance tuning. That test split isn't used for training or per-model hyperparameter tuning.

## Does ImageNet initialisation improve generation, and by how much?

Natural-image initialisation lowers gFID in both latent and pixel paradigms, but the size of the gain differs. The authors attribute the smaller latent gain to the VA-VAE tokeniser, which reconstructs radiology images with rFID 1.88 despite no medical training. Pixel diffusion has no tokeniser, so the denoiser takes the prior directly and transfer helps more.

![Table 1: RadImageNet (RadIN) 256×256 gFID across the three denoising paradigms.rFID is the off-the-shelf tokenizer reconstruction FID; EP. is the number of Rad…](https://refivu.com/papers/1c7517ae-6cfe-4649-8d27-3bcb27c3fdd7/figures/figure-307a10e498d8ed4d20d870013e22086e.png?thumb=512)

**Table 1** .RadImageNet (RadIN) 256×256 gFID across the three denoising paradigms.rFID is the off-the-shelf tokenizer reconstruction FID; EP. is the number of RadIN training epochs; PARAMSreports trainable denoiser parameters only;∆ init and∆ init%is the absolute and relative gFID improvement of IN (✓) vs RANDOM(✗) Denoiser, as indicated in INITcolumn.Bold= best per category.

[Original paper](https://arxiv.org/abs/2611.05192v1) · [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/)

The table gives the latent and pixel numbers side by side for RadImageNet at 256×256. The MedVAE tokeniser is weaker, with rFID 6.35 against 1.88 for VA-VAE. The authors read this as a sign that limited medical data and optimisation hurt MedVAE, not as a failure of medical data in general.

Scaling to H/16 (952M) doesn't improve gFID, so capacity beyond L/16 gives no clear gain on RadImageNet. On BraTS single-channel, IN lowers JiT-L/16 gFID from 37.93 to 29.34, a gain of 8.59. Across the datasets, natural-image initialisation gives the pixel denoiser a consistent gain, so the authors use JiT as the study object.

Table 9 reports seed variance for the RadImageNet runs, which helps judge whether these gaps exceed noise.

## Clinical proxies on synthetic pools

A lower FID alone doesn't show that generated scans are clinically useful, so the authors ran two proxy checks. They trained two JiT-B/16 models, one from scratch and one from IN, on the whole RADIN dataset. Both models were conditioned on all 67 classes, and each generated 100k samples over the 19 validation classes. Because the three 100k pools share identical pathology distributions, differences between them come from the models.

The IN model reached gFID 40.81 and FD-RAD 37.99, while the scratch model reached 72.67 and 87.46. FD-RAD is a Fréchet distance over 93 radiomic features, which capture low-level image properties, measured against the real 100k pool. MACROF1 for a ResNet-50 classifier rose from 0.43 for scratch to 0.47 for IN. A classifier trained on the real data pool reached 0.72, so the synthetic pools sit below that reference.

The authors present these numbers as proxies for clinical fidelity rather than as clinical validation. Across the two pools, lower gFID went with lower FD-RAD and higher MACROF1. That pattern links the generation gain from natural-image initialisation to radiomic and pathology-level signal.

## Semantic probes versus spatial structure

The first hypothesis is that pretraining helps through semantics, either by transferring semantic features or by giving a start from which stronger semantics are learned. Linear probes on frozen JiT-B/16 features classify the 19 RADIN pathology classes at 0.56 for both scratch and IN models. Yet scratch generates far worse samples, with gFID 55.50 compared to 36.48 for IN.

Probe accuracy therefore doesn't explain the transfer benefit, since the two models look alike semantically but differ in generation. The same probing in latent space points the same way: the scratch model probes higher than the IN-init (0.557 versus 0.510) yet generates worse.

![Figure 2: Semantic probing.Top-1 accuracy of linear probes on frozenJiT-Brepresentations classifying19RADIN pathology classes, by layer depth and noise levelt.…](https://refivu.com/papers/1c7517ae-6cfe-4649-8d27-3bcb27c3fdd7/figures/figure-56c6c1490d8e51a481674d3d2d649684.png?thumb=512)

**Figure 2** .Semantic probing.Top-1 accuracy of linear probes on frozenJiT-Brepresentations classifying19RADIN pathology classes, by layer depth and noise levelt. Averages over three runs.

[Original paper](https://arxiv.org/abs/2611.05192v1) · [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/)

The second hypothesis is that the benefit lies in spatial structure, which the authors measure on the denoiser's own internal representations. The original LDS metric gave inconclusive results on denoiser features, so the authors changed it. LDSC mean-centres the tokens before computing the cosine kernel and excludes the first and last blocks, which stay close to the pixel or latent space.

Across 12 JiT variants, LDSC tracks gFID with \|r\| = 0.846 and a fitted slope of −296.6.

The authors read this as one channel through which pretraining works, not as the whole account.

## Shared representations in mixed-domain training

Mixed-domain training asks whether one denoiser represents natural and medical images in a similar way. They measured the per-block cosine similarity of its representations, concatenated over the token sequence, under natural and medical inputs. Blocks 0 to 16 stay highly similar across domains, with cosine at 0.7 or above, so the model computes similar representations for both there.

Blocks 17 to 22 behave differently, with cross-domain cosine dropping to roughly 0.35 to 0.50. This suggests domain-specific behaviour in the late blocks, where the denoiser stops treating the two domains alike.

![Figure 4: Cosine similarity of internal representations in mixed-JiT-L/16.Blocks (y-axis) and noise levelst(x-axis). Intra-class and intra-domain pairs (top ro…](https://refivu.com/papers/1c7517ae-6cfe-4649-8d27-3bcb27c3fdd7/figures/figure-bbd99af6f73487b19aed997be48ef5ba.png?thumb=512)

**Figure 4** .Cosine similarity of internal representations in mixed-JiT-L/16.Blocks (y-axis) and noise levelst(x-axis). Intra-class and intra-domain pairs (top row); Cross-domain pairs (bottom row).

[Original paper](https://arxiv.org/abs/2611.05192v1) · [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/) · Efthymios Georgiou, Ioannis Kakogeorgiou, Sarah Brüningk · From Natural Images to Medical Scans: Transferability of Diffusion Models for Medical Image Generation · Original paper figure · Extracted the figure area from page 7 of the original PDF.

This structure fits the earlier hypothesis that pretraining mainly gives spatial organisation rather than semantics. Figure 4 shows the same comparison across blocks and noise levels, with intra-class and intra-domain pairs in the top row. Cross-domain pairs appear in the bottom row of that figure. Because early representations are shared, the authors asked whether adding natural images to medical training helps.

The 1:1 mix reached 31.80, a small gain that the authors say sits near gFID noise.

The mixing result is a fidelity gain on medical data, not a change in what the model learns about natural images. The authors use it to show that natural images can help medical generation even when medical data dominates the mix. They don't test mixed training beyond the JiT-L/16 model and the ratios in this sweep.

## Medical pretraining and statistics-matched starts

The natural alternative to IN initialisation is pretraining on medical data, and the authors trained their own denoiser because no 2D radiology denoiser existed at a compatible architecture. Direct IN fine-tuning reached 31.73, so the medical-pretrained route ended 5 gFID worse than natural-image transfer. A RADIN stage added on top of IN helped only slightly, with the gain sitting within seed noise (σIN = 0.41).

For the multi-channel target, the authors inserted an intermediate single-channel medical stage before transferring to multi-channel BraTS. Direct IN transfer gave the best result at 40.17, while the medical stages only made things worse. A BraTS stage gave 50.90 and a RADIN stage gave 75.40, so inserting a medical stage only hurts in this setup.

Medical pretraining therefore doesn't reproduce the benefit of natural-image initialisation here.

The second alternative tests whether ImageNet only sets a useful per-tensor scale, which statistically matched (ST) starts should recover. ST resamples each tensor from a Gaussian with the per-tensor mean and variance of the IN weights, so it keeps the statistics but not the learned values.

## Data scaling and block reliance

A third hypothesis is that more medical data lets scratch training reach what transfer already provides. With 25% of the data, the IN model reaches gFID 42.5, while scratch on 100% of the data reaches 55.5. Scratch does not converge at 25%, so that run gives no usable comparison point. Fitting FID as a power law in data size, FID ∝ N^-α, gives α of 0.29 for random and 0.11 for IN.

Block reversion asks which blocks a fine-tuned model actually relies on. The method resets one transformer block of a fully fine-tuned JiT-L/16 to its IN weights and measures the gFID change. Reverting the first transformer block raises gFID by about 170, far more than any other block. That first block drifts less than the deeper blocks, so parameter drift doesn't indicate functional importance.

The second and final blocks also matter, while several intermediate blocks cause smaller changes.

Activation renormalisation rescales the reverted block's output to the original per-channel statistics. Without renormalisation, reverting the first block gives +167.4, and with it the change is +101.0. The damage persists after renormalisation, so activation mismatch alone doesn't explain the first-block effect.

## What the results do not establish

The clinical evidence rests on FD-RAD and a MACROF1 classifier, which the authors present as proxies for clinical fidelity. Pathology classification uses a ResNet-50 trained on real and synthetic pools, with the real-data classifier reaching 0.72. Seed spread is reported only for JiT-B/16 and LDiT-XL/1, so the JiT-L/16 and JiT-H/16 numbers rest on single runs in the main table.

The seed table shows LDiT-XL/1 IN at 16.43 against RAND at 19.05, and JiT-B/16 IN at 36.48 against RAND at 55.50.

The data-scaling result is an illustrative extrapolation from three data fractions, 25%, 50% and 100% of RadImageNet. The extrapolation scales data quantity, not diversity, so it doesn't test whether more varied medical data would close the gap. Experiments use 2D slices at 256×256 with cfg 1.0, and the 3D setting is left for later work. The RadImageNet set holds about 0.5M images, and at that size H/16 gave no clear gFID gain over L/16.

LDSC explains about two-thirds of the pretraining gap on average, so spatial structure is one channel, not the whole account. The authors don't establish what exactly is inherited, such as edges, textures or contours. The BraTS and RadImageNet results come from two radiology datasets, so they don't cover other medical modalities.

## Paper info

- **Authors**: Efthymios Georgiou, Ioannis Kakogeorgiou, Sarah Brüningk
- **Venue**: arXiv · Preprint
- **First published**: 2026-11-3
- **Added**: 2026-11-6
- **Updated**: 2026-11-3
- **Version**: v1
- **arXiv**: 2611.05192
- **Category**: cs.CV
- **Original paper terms**: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/)
- **What we show**: Paper info, commentary and permitted figures from the original paper

[Original paper ↗](https://arxiv.org/abs/2611.05192v1) · [PDF ↗](https://arxiv.org/pdf/2611.05192v1)

AI commentary is a separate explanation from the original paper and may contain errors. The original paper and figures follow each source's terms of use and any rights noted separately.

## Abstract

Transfer learning from natural images is standard in supervised and increasingly adopted in self-supervised medical image analysis, but its role in generative modelling, and in particular diffusion denoisers, remains underexplored. Medical diffusion models typically train the denoiser from scratch, with no systematic evaluation of natural-image transfer. We analyse this across latent and pixel paradigms, model sizes (131M-952M) and two radiology datasets (RadImageNet, BraTS), and ask which aspects of transfer support generation. We find that: i) Natural-image initialisation consistently improves generation, by 21-34% relative gFID in pixel space against 14% in latent space, where the tokeniser supplies much of the prior. gFID gains mirror downstream pathology classification and radiomic-feature FD, both proxies for clinical fidelity. ii) Benefits reflect spatial structure, not semantics: semantic probing does not predict generation quality, whereas a spatial-structure metric adapted to internal denoiser representations tracks gFID at $\|r\|=0.85$, positioning spatial organisation as a channel through which pretraining manifests. iii) Mixed-domain denoiser training shows that natural and medical images share similar layer-wise representations up to the late blocks, and mixing natural images into medical training improves fidelity. iv) Transfer benefit is tied to natural image initialisation, outperforming in-domain medical pretraining and several reinitialisation schemes. Overall, natural image denoisers transfer positively to medical ones in our setup. Code is available at https://github.com/CAIROLab-Bern/rad-dit

## Quote from the paper

Efthymios Georgiou, Ioannis Kakogeorgiou, Sarah Brüningk (2026). From Natural Images to Medical Scans: Transferability of Diffusion Models for Medical Image Generation. arXiv:2611.05192v1. https://arxiv.org/abs/2611.05192v1

**BibTeX**

```
@misc{georgiou2026from,
  title = {{From Natural Images to Medical Scans: Transferability of Diffusion Models for Medical Image Generation}},
  author = {Efthymios Georgiou and Ioannis Kakogeorgiou and Sarah Brüningk},
  year = {2026},
  eprint = {2611.05192},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.05192v1}
}
```

## Other paper commentary

- [Large Scale GAN Training for High Fidelity Natural Image Synthesis](https://refivu.com/en/papers/93f6ad29-8cca-4630-9a3b-d12f9ad91854-large-scale-gan-training-for-high-fidelity-natural.md)
- [Generative Modeling by Estimating Gradients of the Data Distribution](https://refivu.com/en/papers/f3ef856d-6161-4eaa-b2c9-6a0c3f1ff432-generative-modeling-by-estimating-gradients-of-the-data.md)
- [Improved Techniques for Training GANs](https://refivu.com/en/papers/fa2b409d-90c8-47af-916c-aa43ebfdf357-improved-techniques-for-training-gans.md)
- [Variational Inference with Normalizing Flows](https://refivu.com/en/papers/681d4ceb-2dde-4627-a4ad-6ee307d4d2ec-variational-inference-with-normalizing-flows.md)
- [Generative Adversarial Imitation Learning](https://refivu.com/en/papers/4c0dc7dc-4282-4fe9-8bb5-0b267ba684d1-generative-adversarial-imitation-learning.md)
- [Unsupervised Representation Learning with Deep Convolutional Generative Adversarial Networks](https://refivu.com/en/papers/9ce22173-9f5b-4145-a8ef-d0ea3e39660a-unsupervised-representation-learning-with-deep-convolutional.md)
- [How many sorted projections determine n points in k dimensions?](https://refivu.com/en/papers/56ddc92f-406c-48d0-903d-def2129a08e3-how-many-sorted-projections-determine-n-points-in.md)
- [Reasoning-Trace Overflow in Code Generation: An Empirical Study of Explicit Reasoning Models](https://refivu.com/en/papers/341947d7-6234-48fc-bf19-74e8c2056166-reasoning-trace-overflow-in-code-generation-an-empirical.md)
- [A Circuit for In-Context Learning](https://refivu.com/en/papers/b4e6d6ca-00f5-4939-8c04-a01635eef882-a-circuit-for-in-context-learning.md)
- [From AutoResearch to Continual AutoResearch: Do Agents Learn Across Tasks?](https://refivu.com/en/papers/9dffba31-2edb-48c7-8770-8675f1f716c3-from-autoresearch-to-continual-autoresearch-do-agents-learn.md)
- [MedPhysBench: A Benchmark for Evaluating Language Models on Medical Physics Calculations and Error Detection](https://refivu.com/en/papers/8e140d70-2b40-4fed-80e5-c88449a660ed-medphysbench-a-benchmark-for-evaluating-language-models-on.md)
- [Personas Are Not People: Identity as State, Not Attribute](https://refivu.com/en/papers/9138858c-ab78-4e20-ae09-ef713b23e52d-personas-are-not-people-identity-as-state-not.md)

## Terms in this paper

- [FID](https://refivu.com/en/terms/e110afe65f86-fid)
- [Random](https://refivu.com/en/terms/bffd038e7fd5-random)
- [gFID](https://refivu.com/en/terms/440f05515cde-gfid)
- [BRATS](https://refivu.com/en/terms/4dec22199e5a-brats)
- [density](https://refivu.com/en/terms/ff1ae20d8b4c-density)
- [LDS](https://refivu.com/en/terms/c3e996452c93-lds)

---

AI-written text can contain mistakes. [Refivu](https://refivu.com/en/papers/1c7517ae-6cfe-4649-8d27-3bcb27c3fdd7-from-natural-images-to-medical-scans-transferability-of)