# Can decision models extract clinical data from cancer pathology reports? An evaluation of accuracy, calibration, and failure modes

Decision models extract cancer pathology fields about as accurately as a generative model

Indranil Mallick, Paromita Roy · arXiv · 2026-11-15

- **Problem** Generative language models return free text that must be parsed, and they give no direct confidence for each value. Decision models, which pick an option and return a probability, had not been tested on clinical text.
- **Method** Decision models choose one option per question from a fixed list and return a probability for each option. The authors ask 25 field questions per pathology report with two open-weights models, Nimble 9B and Tev1 4B.
- **Results** Tev1 4B reached 0.917 mean field accuracy, matching Qwen3.5 9B at 0.918. Tev1 was about four times faster per report, at 15.0 s against 60.8 s.

![Figure 4: (a) Reliability diagram: observed accuracy against the probability of the chosen option, pooled over all fields (bins with at least 20 answers). (b)…](https://refivu.com/papers/68c81f1f-22ac-4830-b068-46e0177f7953/figures/figure-68ac7ee7375fc307bfdd53269ea86f36.png?thumb=512)

**Figure 4** :(a) Reliability diagram: observed accuracy against the probability of the chosen option, pooled over all fields (bins with at least 20 answers). (b) Accuracy of the answers kept against the share of answers kept, as the probability threshold for acceptance rises.

[Original paper](https://arxiv.org/abs/2611.20129v1) · [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/) · Indranil Mallick, Paromita Roy · Can decision models extract clinical data from cancer pathology reports? An evaluation of accuracy, calibration, and failure modes · Original paper figure · Extracted the figure area from page 9 of the original PDF.

## Why pathology extraction stays hard

Most of what staging and adjuvant planning need is written into pathology reports for oral cavity squamous cell carcinoma. Much of that content still sits in narrative text, and manual abstraction for registries and audit is slow, costly and error-prone. Large language models can automate much of this work, and models run locally keep reports inside the hospital.

Their outputs are free text, so each value must be parsed and compared with the permitted options. Nothing in that output says how likely any single value is to be right, so each one needs equal scrutiny.

Decision models were introduced in September 2026 as a different kind of model. Instead of writing text, a decision model reads a state and answers typed questions, each with a fixed option list, by choosing one option and giving every option a probability. Two open-weights models run locally: Nimble 9B is a low-rank-adapted Qwen3.5 9B, fit on 2,676 curated examples with synthetic labels, and Tev1 4B is an experimental fine-tune of Qwen3.5 4B.

Clinical text was absent from training for both models. The developers of Nimble describe its probabilities as normalised scores, not as calibrated estimates of correctness.

No published study had yet tested decision models on clinical text, so the question was open. The study asks whether the two models can extract 25 fields from 1,113 oral cavity cancer pathology reports, judged against a prospectively maintained clinical database.

## Asking each field as a typed choice

The core idea is to ask each field as a multiple-choice question, so the model returns an allowed value and a probability rather than prose. The state is the report text, with a two-sentence note on what kind of report it is placed before it. All 25 questions are choice questions, and each comes with an instruction and short text describing its options.

Question wording and option labels come from the field definitions used for the generative models, and a script checks that every option matches an allowed generative value. All 25 questions go in one request per report, and the endpoint builds one prompt per question, so the report is read once for each question. When scores tie, the first listed option wins, and the questions were never revised after seeing results.

Tumour size, for example, is binned as 20 mm or less, more than 20 to 40 mm, or more than 40 mm. The generative models' numeric outputs went through the same binning function, so every model was judged on the same categories.

Scoring is exact: after case and whitespace are normalised, a chosen value either equals the reference or doesn't. The main outcome, mean field accuracy, is a share of all report-field cells across the 25 fields that were answered correctly. A case-level bootstrap with 2,000 resamples gives its confidence interval.

## Overall accuracy against the comparators

Tev1 4B scored 0.917 mean field accuracy (95% CI 0.913 to 0.920), compared to 0.918 for Qwen3.5 9B, a difference of −0.002 with p=0.26. So the 4B decision model matched its generative comparator overall, despite being about half the size of Qwen3.5 9B. Nimble 9B scored 0.862, which is 0.056 below its own base model Qwen3.5 9B. GLM-5.3-flash, run through a cloud API, scored 0.986, and the authors use it as a ceiling rather than as a routine candidate.

![Figure 1: Mean field accuracy with 95% confidence intervals (case-level bootstrap, 2,000 resamples) for the two decision models (blue) and the two generative c…](https://refivu.com/papers/68c81f1f-22ac-4830-b068-46e0177f7953/figures/figure-8b9fb305e5d36d0724cb0f71ffba85a5.png?thumb=512)

**Figure 1** :Mean field accuracy with 95% confidence intervals (case-level bootstrap, 2,000 resamples) for the two decision models (blue) and the two generative comparators; 25 fields, 1,113 reports.

[Original paper](https://arxiv.org/abs/2611.20129v1) · [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/)

Tev1 and Qwen3.5 9B tie overall, but their errors fall in different fields. Tev1 was more accurate on primary tumour fields, by 0.018, but less accurate on nodal fields and on binned numeric fields, where the gap was −0.103. The overall score therefore hides where each model is weak.

Running locally on the GPU, Tev1 averaged 15.0 s per report, compared to 60.8 s for Qwen3.5 9B. Tev1 is about four times faster even though Qwen3.5 9B has more than twice as many parameters. The cloud GLM run took 23.6 s, a figure tied to the provider's hardware, so it can't be compared directly. Tev1 used a mean of 26,559 input tokens per report, compared to 146,515 for Nimble 9B on the same 25 questions.

## Where the decision models go wrong

Most decision-model errors followed a pattern instead of scattering across fields. Both models matched GLM-5.3-flash on simple dichotomous fields such as PNI, where Tev1 scored 1.000 and Nimble 0.997. Nimble's pT accuracy was 0.488, against 0.992 for Tev1 on the same question. Nimble answered T0 for 194 of 332 T2 tumours. The robustness experiments traced this error to asking 25 questions in one request, not to the order of the options.

Tev1 never picked the Bone not resected option, so the 532 bone-free reports were labelled Not involved. That left Tev1's bone accuracy at 0.503. Its bone-invasion answers still carried a mean probability of 0.845, with an expected calibration error of 0.370. Absence fields such as bone invasion, masticator space and skin ask the model to recognise that a structure is missing.

The authors suggest asking first whether a structure was resected, which may avoid both errors.

On thickness they scored 0.835 and 0.770, while GLM-5.3-flash and Qwen3.5 9B both scored 0.980 or more on these fields. The authors therefore suggest extracting numeric values and binning them in code.

Tev1 detected 16 of 33 involved margins, a sensitivity of 0.48. Nimble over-called close or involved margins, with a positive predictive value of 0.47.

## Why request size mattered for Nimble

Option order looked like a possible cause first, because Nimble's wrong pT answers sat three places earlier in the list than the correct stage. The authors tested this with reversed, shuffled and reduced option lists on 200 reports, sending only the T category and margin questions. Nimble's wrong answers didn't move with the options, so option position doesn't explain its pT errors.

Request size, by contrast, did explain Nimble's pT errors. On the same 200 reports, two questions per request raised Nimble's pT accuracy from 0.490 to 0.850, instead of 25 questions. Among the 170 reports with a recorded pT, the same change took accuracy from 0.576 to 0.994. Tev1 didn't change, because its pT accuracy stayed at 0.990 with either setting.

Repeating the 25-question run on 100 reports changed only 3 of 2,500 answers for Nimble, so the error is reproducible.

Token counts offer a possible mechanism for the request-size effect. Tev1 used about 1,060 input tokens per question, whereas Nimble used about 5,860. In an earlier Ollama pilot, Nimble needed about 15,600 input tokens per report with one question per request, against about 134,000 when batched. The authors infer that each per-question prompt carries the whole question bank, so other questions' options compete with the target question.

The same weights gave pT accuracy between 0.49 and 0.99, depending on how many questions shared a request. So a decision model has to be validated in the exact configuration in which it will run. The Nimble results in the paper come from the batched setup, so they don't show the model at its best.

## Whether the probabilities can be trusted

Across fields, the probability of the chosen option separated correct answers from wrong ones, with AUROC 0.878 for Nimble and 0.844 for Tev1. Pooled expected calibration error came to 0.022 for Nimble and 0.026 for Tev1, so the probabilities look well calibrated overall. The Brier scores were 0.089 and 0.067, and the paper reports them alongside a reliability diagram in Figure 4a.

Pooling hides the fields where errors were systematic, and those fields were poorly calibrated. For Tev1's bone invasion, expected calibration error was 0.370, with a mean probability of 0.845 at an accuracy of 0.503. Tev1 never chose "Bone not resected", so its bone answers were a consistent mapping rather than an uncertain guess. The authors argue that a probability threshold can't catch this kind of error, so field-level validation and consistency rules are needed.

Accepting only answers with probability at least 0.9 kept 65.7% of Nimble's answers at 97.3% accuracy. Tev1 kept 69.7% of its answers at 97.7% accuracy at the same threshold. At 0.95, Tev1's kept answers were 98.9% accurate and covered 60.0% of its answers. That suits data-quality checks, because the few disagreements among accepted answers form a short list for review by hand.

The escalation step builds on these scores, because a threshold decides which answers leave the decision model. The authors therefore decide escalation per field and per answer rather than per report. Cloud escalation sends text outside the hospital, and the authors used GLM-5.3-flash only as an upper bound, not for routine use.

## Escalating low-probability answers

The cascade keeps a decision-model answer when its probability reaches a threshold t. Otherwise, it takes the answer from another model, or from a human reviewer assumed to be correct. At a 0.94 threshold, Tev1 reached an MFA of 0.982 with 37.7% of cells escalated to GLM-5.3-flash. Nimble reached 0.981 with 40.1% escalated, so both models came within 0.5 percentage points of GLM alone.

Escalating to Qwen3.5 9B gave at most 0.927, at a threshold of 0.66 with 8.3% of cells escalated.

A human reviewer checking answers below 0.95 raised Tev1 to 0.993, with 40.0% of cells reviewed. Escalating whole reports saves no work, because at least 89% of reports had a low-probability answer at every threshold from 0.8 upwards. So the authors decide escalation per field and per answer, in four steps. The first step assigns the decision model only to fields it handles accurately and calibrates well, such as PNI, LVI, grade, WPOI-5 and pT for Tev1.

The third step applies the consistency rules to the combined output and sends breaking reports to a person.

The design resembles a model cascade, in which the cheap model takes most queries. Where the stronger model is a cloud service, escalated text leaves the hospital, so a strong local model is needed there. The same threshold also gives a short list for data quality checking. At 0.95, Tev1 accepted 60.0% of its answers at 98.9% accuracy, so the disagreements in those answers can be checked by hand.

## Where decision models could fit in pathology workflows

Triage looks workable for a few findings, because both decision models kept sensitivity between 0.98 and 1.00 for PNI, LVI, WPOI-5 and cortical bone invasion. Margins are a different story, since Tev1 caught involved margins with a sensitivity of only 0.485. Depth of invasion over 10 mm shows the same weakness, with Tev1 at 0.511.

At a threshold of 0.95, 60% of Tev1's answers were accepted at 98.9% accuracy, which leaves a short list for manual checks. Both uses can run on a local machine, so patient data stay inside the hospital where cloud processing isn't permitted.

The authors didn't evaluate Jev, because it is a proprietary hosted service. Jev's size, base model and weights haven't been released, which makes its results harder to reproduce. Sending pathology reports to an external provider, as Jev would require, conflicts with routine hospital use. Laya runs locally with open weights, but its 421-million-parameter encoder has a 512-token context in English.

With a median report of 2,102 characters, many reports wouldn't fit beside a question and its options without truncation.

Laya's developers present it as a base model for fine-tuning, not as a zero-shot decision model. GLM-5.3-flash served only as a cloud upper bound, so it isn't a candidate for routine use.

## Limits on transferring these results

The evidence comes from one hospital, one language, one reporting style and one cancer site, so transfer is an open question. The study says its results may not carry over to other report formats. The reference standard is a clinical database that has its own errors.

The main run sent all 25 questions in one request, which understates Nimble's accuracy.

Only two decision models were tested, and both are early releases. The timings come from one machine, so speed comparisons hold only for that hardware. The most accurate comparator, GLM-5.3-flash, ran in the cloud, which may not suit routine use. The authors didn't evaluate Jev or Laya, and Laya's 421-million-parameter encoder has a 512-token context in its English version.

The conclusions therefore cover presence-or-absence findings, while numeric fields need other means.

## Paper info

- **Authors**: Indranil Mallick, Paromita Roy
- **Venue**: arXiv · Preprint
- **First published**: 2026-11-15
- **Added**: 2026-11-17
- **Updated**: 2026-11-15
- **Version**: v1
- **arXiv**: 2611.20129
- **Category**: cs.CL · cs.AI · cs.LG
- **Original paper terms**: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/)
- **What we show**: Paper info, commentary and permitted figures from the original paper

[Original paper ↗](https://arxiv.org/abs/2611.20129v1) · [PDF ↗](https://arxiv.org/pdf/2611.20129v1)

AI commentary is a separate explanation from the original paper and may contain errors. The original paper and figures follow each source's terms of use and any rights noted separately.

## Abstract

Decision models are a new class of language model that, instead of generating text, choose one option per question from a fixed list and return a probability for every option. They have not yet been evaluated on clinical text. We evaluated two open-weights decision models, Nimble 9B and Tev1 4B, for extracting 25 fields from 1,113 oral cavity cancer pathology reports from a single centre, against a prospectively maintained clinical database. We compared them with two generative models: Qwen3.5 9B, run locally, and GLM-5.3-flash, run through a cloud API. Tev1 reached a mean field accuracy of 0.917 (95% CI 0.913 to 0.920), the same as Qwen3.5 9B (0.918; p = 0.26), and was four times faster (15 s against 61 s per report). Nimble reached 0.862 and GLM-5.3-flash 0.986. Both decision models matched GLM-5.3-flash on simple dichotomous categories. They were weak on measurements binned into categories, on fields whose correct answer was not reported, and on some complex decisions (e.g. involved margins). We found that the main cause of the inferior performance of Nimble's came from asking 25 questions in one request: with two questions per request, its accuracy improved. Pooled over fields, the returned probabilities were well calibrated (expected calibration error 0.022 and 0.026), but they did not flag systematic errors within single fields. A simulated strategy of sending answers with a probability below 0.94 to GLM-5.3-flash raised Tev1's accuracy to 0.982, with 38% of answers escalated. Decision models can extract explicitly stated findings from pathology reports quickly on local hardware and return useful probabilities. They should be validated in the configuration in which they will be used, restricted to the fields in which they are reliable, and combined with other methods for numeric values.

## Quote from the paper

Indranil Mallick, Paromita Roy (2026). Can decision models extract clinical data from cancer pathology reports? An evaluation of accuracy, calibration, and failure modes. arXiv:2611.20129v1. https://arxiv.org/abs/2611.20129v1

**BibTeX**

```
@misc{mallick2026decision,
  title = {{Can decision models extract clinical data from cancer pathology reports? An evaluation of accuracy, calibration, and failure modes}},
  author = {Indranil Mallick and Paromita Roy},
  year = {2026},
  eprint = {2611.20129},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.20129v1}
}
```

## Other paper commentary

- [Benchmarking the State of AI for Crop Yield Forecasting: A Global Assessment Across Modeling Paradigms](https://refivu.com/en/papers/4daab0ea-1f2f-4450-a57f-b37ed5816f41-benchmarking-the-state-of-ai-for-crop-yield.md)
- [MarathonTS: a benchmark of long synthetic time series from window assembly and long-series generators](https://refivu.com/en/papers/8582319e-a186-4e8a-b713-0a6f33889f8f-marathonts-a-benchmark-of-long-synthetic-time-series.md)
- [BLiMP-RO: A Benchmark of Linguistic Minimal Pairs for Romanian](https://refivu.com/en/papers/08dabea6-d4d2-4848-af54-4ec2088d0cde-blimp-ro-a-benchmark-of-linguistic-minimal-pairs.md)
- [GDP.xlsx: Benchmarking Frontier Models on Professional Workbooks](https://refivu.com/en/papers/9674f631-c1f8-4d0b-8b24-597c064c097f-gdp-xlsx-benchmarking-frontier-models-on-professional.md)
- [ParseBench-2: Severity-Aware Evaluation of Document Parsing](https://refivu.com/en/papers/6a634f4a-4067-4371-aad1-d4d152a8567d-parsebench-2-severity-aware-evaluation-of-document-parsing.md)
- [Unfinished-Bench: Measuring Rule Violations by Persistent Agents in Realistic Work Environments](https://refivu.com/en/papers/7d1ec24e-9676-4b02-9f95-5b4b4a0829fc-unfinished-bench-measuring-rule-violations-by-persistent.md)
- [Does Learning Order Explain Forgetting? The Lie Bracket as an Early-Warning Signal for Catastrophic Forgetting Without Old Data](https://refivu.com/en/papers/64539a4f-1874-4500-94d4-0df24d9affd4-does-learning-order-explain-forgetting-the-lie-bracket.md)
- [Making Preemption Productive in Long-Output LLM Serving](https://refivu.com/en/papers/9b0d4dbe-5b49-451b-bbf8-332c064c718b-making-preemption-productive-in-long-output-llm-serving.md)
- [Latent World Modeling for Point-Cloud Video Pretraining](https://refivu.com/en/papers/30e3c251-d354-49fe-b4cd-b50f6ce5b11a-latent-world-modeling-for-point-cloud-video-pretraining.md)
- [Mandarin Wh-Indefinites Follow Nonveridicality in Multilingual LLMs, Unlike English any](https://refivu.com/en/papers/b5162ae6-ef0d-43e8-a80d-caae3aca553d-mandarin-wh-indefinites-follow-nonveridicality-in.md)
- [Decode Early, Verify Late: Streaming Offline Speech Recognizers Without Accuracy Loss](https://refivu.com/en/papers/2278ddf0-1374-4673-bc6f-4c55215520e4-decode-early-verify-late-streaming-offline-speech.md)
- [CECAR: Cache & Expert Co-Aware Routing Accelerates On-Device Inference of MoE LLMs](https://refivu.com/en/papers/4e886007-b40a-4b34-ae15-82829e661e98-cecar-cache-expert-co-aware-routing-accelerates-on.md)

## Terms in this paper

- [expected calibration error](https://refivu.com/en/terms/5989f8ad43cb-expected-calibration-error)
- [cascade](https://refivu.com/en/terms/ef171599c78d-cascade)
- [low-rank adaptation](https://refivu.com/en/terms/97f93b5718ac-low-rank-adaptation)

---

AI-written text can contain mistakes. [Refivu](https://refivu.com/en/papers/68c81f1f-22ac-4830-b068-46e0177f7953-can-decision-models-extract-clinical-data-from-cancer)