# Target Recoverability under Selective Labels: A Failure Mode in ECG-Based Acute Coronary Syndrome Prediction

Selective testing can make ECG models rank untested patients backwards

Alexander Schubert, Anton Håkansson, Ziad Obermeyer · arXiv · 2026-11-8

- **Problem** Models trained only on tested patients can learn relationships that fail among untested patients. Testing depends on clinical information the ECG lacks, so diagnoses the ECG cannot detect look predictive in the tested group.
- **Method** The authors train ECG predictors on ECG-visible ACS subtypes and freeze them. They then score untested Nightingale patients, varying only the clinical target and keeping the input and population fixed.
- **Results** ST-MEM reached 0.770 AUROC on catheterized patients but 0.478 for 30-day MACE in untested patients. Models trained on OMI kept discrimination at 0.709.

![Figure 1: Schematic depiction of the bias mechanism.Testing depends on both the model input and](https://refivu.com/papers/6be5f693-4010-4ca4-a6a8-74c4cb667334/figures/figure-d812e367f330aa59434fbc180169eba3.png?thumb=512)

**Figure 1** :Schematic depiction of the bias mechanism.Testing depends on both the model input and

[Original paper](https://arxiv.org/abs/2611.11063v1) · [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/) · Alexander Schubert, Anton Håkansson, Ziad Obermeyer · Target Recoverability under Selective Labels: A Failure Mode in ECG-Based Acute Coronary Syndrome Prediction · Original paper figure · Extracted the figure area from page 3 of the original PDF.

## Where selective labels break ECG training

Many diagnostic models train on outcomes that only appear once clinicians pick patients for further workup. Patients with observed labels can differ from the population where the model will eventually be used. The authors study a sharper case, where the diagnosis includes components the model's input cannot detect. In the full population, such components are simply hard to predict, so the model gains little from them.

Under selective testing, though, the decision to test can turn that difficulty into a misleading signal. Conditioning on being selected can link the input to outcome parts it cannot see, a form of collider bias.

ACS suits this test because its subtypes differ in how visible they are on the ECG. STEMI is defined by characteristic ST-segment abnormalities, while OMI adds patterns linked to acute occlusion. UA and NSTEMI may show nonspecific changes or a normal ECG, so a normal ECG doesn't rule out ACS. UA involves ischemia without troponin-detectable myonecrosis, so its diagnosis leans on symptoms and further testing.

A single broad ACS label therefore merges subtypes with very different ECG recoverability. Definitive labels come only from invasive angiography, so the labeled population is the catheterized one.

The authors use the Chongqing cohort, in which all 18,909 patients underwent coronary angiography. Chongqing gives detailed labels for alternative ACS phenotypes, but only within a selected population. The Chongqing dataset contains 19,955 ECGs sampled at 500 Hz. Nightingale holds ECGs for patients both inside and outside the subsequent testing pathway.

That split lets the authors compare predictive relationships between tested and untested patients.

## A selection effect that looks like signal

Testing decisions draw on the ECG and on clinical information the ECG doesn't carry. If that extra information also reflects the hidden disease component, testing enriches the tested group for that component while the ECG stays the same. A model trained only on tested patients can then learn that low-risk-looking ECGs go with higher risk.

This is a selection-induced association, and it doesn't reflect physiology.

The authors write the target as Y equals Y\_R or Y\_U, where Y\_R is recoverable from the ECG input X. In the idealised case, Y\_U carries no predictive signal in X. Bayes' rule gives the odds of Y\_U among tested patients with input x, scaled by a(x) over b(x). Among untested patients, the same prior odds are scaled by (1 minus a(x)) over (1 minus b(x)) instead.

When Y\_U also drives testing, a(x) is greater than b(x), so tested patients with a low-risk ECG carry more Y\_U than the underlying population. Untested patients with the same ECG carry less Y\_U, which is why the two groups disagree.

Under mutual exclusivity of Y\_R and Y\_U, the tested score is f\_sel(x) equals p\_R(x) plus p\_U^(1)(x). The untested score is f\_unt(x) equals p\_R(x) plus p\_U^(0)(x). For a low-risk-looking input x\_L and a high-risk input x\_H with p\_R(x\_L) below p\_R(x\_H), the tested ranking reverses once the Y\_U gap is large enough. The condition is that p\_U^(1)(x\_L) minus p\_U^(1)(x\_H) exceeds p\_R(x\_H) minus p\_R(x\_L).

Among untested patients, the ordering can stay with x\_H above x\_L, so a model fit on tested patients points the wrong way. Selective labels thus turn a lack of recoverability into a misleading predictive relationship, which the simulation then tests.

## What the simulation tests

The authors built a synthetic setup in which the model sees a signal X on \[0,1\]. The recoverable component follows P(Y\_R = 1 \| X = x, Y\_U = 0) = 0.05 + 0.30x, while Y\_U stays independent of X. A clinical signal C stays hidden from the model but tracks the unrecoverable component, with P(C = 1 \| Y\_U = 1) = 0.90 and P(C = 1 \| Y\_U = 0) = 0.10.

Testing follows a targeted policy of 0.90 when C = 1 and 0.05 + 0.85x when C = 0. The selective-testing strength λ blends that policy with random testing at 0.50. The share q, the fraction of positive outcomes from the unrecoverable component, is varied separately.

Instead of fitting models, the authors compute ideal tested-population scores from the known probabilities. This removes estimation error, so the reversal can appear even when a score estimates risk perfectly among tested patients. The broad-label score is P(Y = 1 \| X = x, S = 1), and the modality-aligned score is P(Y\_R = 1 \| X = x, S = 1).

At fully targeted testing and q = 0.70, the broad-outcome score fell to an AUC of 0.38 in the simulation. The score trained on the recoverable component stayed informative over the same sweep. A second sweep holds testing fully targeted and varies q from 0 to 0.80. The broad score fell below chance once unrecoverable cases made up approximately 35 to 40% of positive outcomes.

The recoverable score remained above chance throughout that sweep.

Inverse-odds weighting based only on X didn't prevent the reversal. Weighting with the true selection probabilities, which include C, restored positive discrimination.

## Two cohorts that expose the selection

The Chongqing angiography cohort holds labels only from patients who were catheterized, so every patient there was selected for invasive evaluation. Only ECGs recorded before angiography are kept, so the model sees the same information a clinician had at the time of the decision. Chongqing therefore supplies the labels for each ACS subtype, but it cannot show what happens to patients who were never catheterized.

The Nightingale cohort supplies the comparison the authors need, because its ECGs come from emergency-department encounters both inside and outside the testing pathway. An encounter counts as catheterized when cardiac catheterization occurred within 10 days, and as untested when neither catheterization nor a stress test was ordered. Among catheterized encounters, revascularization means stent placement or CABG within 10 days, and it serves as the label for model training.

Across all encounters, the outcomes are 30-day MACE, troponin-positive MACE, and death, which are measured in both groups.

ST-MEM, ECGFounder, and ECGFlow are fine-tuned on revascularization within the catheterized Nightingale group, to predict revascularization by PCI or CABG within 10 days. Revascularization serves as the label because coronary anatomy and the decision to intervene are visible only after a patient enters the invasive pathway. The authors then evaluate these models on untested patients against 30-day MACE, which they call an imperfect but clinically meaningful proxy for potentially missed ACS.

Troponin-positive MACE and 30-day mortality serve as additional outcome definitions to check how robust that proxy is.

For the target comparison, Chongqing predictors for broad ACS, OMI, AMI, STEMI, NSTEMI, and UA are built with a common training pipeline. These predictors are frozen and evaluated externally in Nightingale, separately among catheterized and untested patients. Holding the input modality and downstream population fixed isolates the effect of the clinical target chosen for learning.

## Catheterized accuracy doesn't transfer

ST-MEM, ECGFounder, and ECGFlow were each fine-tuned to predict revascularization by PCI or CABG within 10 days in catheterized patients. Within that catheterized population, ST-MEM reached 0.770, ECGFounder 0.745, and ECGFlow 0.740 in cath revasc. AUC. Across the three encoders, the catheterization-cohort AUC ranged from 0.740 to 0.770. These scores show that the models rank patients well once they are already inside the invasive testing pathway.

![Table 1: ECG model performance in catheterized and untested patients.AUCs (95% CI) for 10-](https://refivu.com/papers/6be5f693-4010-4ca4-a6a8-74c4cb667334/figures/figure-ae4bde053471f5ad0b71e70e9fcbd0d8.png?thumb=512)

**Table 1** :ECG model performance in catheterized and untested patients.AUCs (95% CI) for 10-

[Original paper](https://arxiv.org/abs/2611.11063v1) · [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/)

Applied to untested patients, the same models scored 0.478 for ST-MEM, 0.422 for ECGFounder, and 0.381 for ECGFlow on 30-day MACE. ST-MEM was the highest of the three, yet it still fell under chance. Three different encoders produced the same reversal, so it doesn't hinge on one architecture.

For 30-day death, ST-MEM scored 0.442, ECGFounder 0.396, and ECGFlow 0.387, all below chance. Troponin-positive MACE gave a mixed result, with ECGFounder at 0.437 and ECGFlow at 0.385, both below chance. ST-MEM sat near chance on that endpoint at 0.497. These outcomes capture different aspects of clinical risk, so the authors don't tie the finding to how MACE is defined.

They didn't test a different proxy for missed ACS in this comparison.

## Which target transports

The Chongqing predictors share one ECG input and one downstream population, so the clinical target is the only variable that changes. A common training pipeline built predictors for broad ACS and for OMI, AMI, STEMI, NSTEMI, and UA. The authors froze these predictors and evaluated them externally in Nightingale, separately among catheterized and untested patients.

For 30-day MACE among untested patients, OMI reached 0.709, STEMI 0.693, and NSTEMI 0.680. Broad ACS scored 0.517, while UA fell to 0.310. Higher UA scores therefore went with lower observed 30-day MACE risk among untested patients.

For 30-day death, OMI scored 0.682 and UA scored 0.332, against 0.523 for broad ACS. Observed 30-day MACE rose from 2.7% to 30.5% across OMI-score deciles. Across UA-score deciles, it fell from 34.3% to 5.7%. The broad ACS model produced a U-shaped curve, with elevated risk at both ends and near-chance overall discrimination. The authors attribute this mix to ECG patterns of infarction combined with associations learned from tested patients with little ECG evidence of disease.

OMI and STEMI carry stronger ECG manifestations, while UA and NSTEMI may be less directly recoverable from the ECG. The authors note that these differences agree with internal validation in Chongqing, where discrimination varied across clinical targets. Target choice, then, changes transport across the selection boundary even when the input modality stays fixed.

## Why both ingredients are needed

The simulations show that selective testing alone and limited target recoverability alone don't produce the reversal. The reversal emerged only when both were present, so the authors treat the failure as an interaction rather than a property of either factor. Without selection, an unrecoverable component mostly adds irreducible uncertainty to the predictions.

Under selective observation, the same component can instead become a shortcut that reverses risk ranking outside the selected population.

The ACS results follow the same pattern, with ECG models trained on revascularization in catheterized patients reversing their ordering in untested patients. Target choice changed the transport outcome: OMI, STEMI, and NSTEMI predictors kept positive discrimination for later adverse events. The UA predictor was inversely related to risk, with 30-day MACE AUC 0.310 in untested patients.

The broad ACS model was nearly uninformative, with an AUC of 0.517 for 30-day MACE in untested patients. The risk gradients match the theory: monotonically increasing for OMI, decreasing for UA, and U-shaped for ACS.

The practical consequence is that a clinically valid outcome isn't automatically a good training target under selective labels. In ACS, this favors targets tied to ECG-manifested pathology, such as acute occlusion. For phenotypes like UA, the authors suggest multimodal inputs that add symptoms, biomarkers, or other clinical data. They also argue that selectively trained models should be evaluated in populations outside the testing pathway whenever possible.

The authors extend the point to breast imaging, where ductal carcinoma in situ often shows microcalcifications on mammography. The experiments here cover ACS only, so this breast cancer extension is the authors' hypothesis.

## Constraints bounding the claims

The paper treats 30-day MACE as an imperfect proxy for missed ACS, since not every missed ACS leads to a MACE event. MACE may also stem from causes unrelated to a missed ACS, so the outcome can't stand in for ground-truth ACS. Troponin-positive MACE and 30-day death serve as additional outcome definitions to check how sensitive the results are to this proxy.

The untested group is defined only by the absence of catheterization or stress testing within the study windows. Coronary labels are unobserved for untested patients, so their outcomes are read through MACE rather than confirmed ACS. The Nightingale data come from one urban academic hospital, which limits how far the findings can be generalised.

The target comparison uses one external cohort: Chongqing-trained models are evaluated in Nightingale and nowhere else.

The simulations use known probabilities and ideal scores, which isolates the mechanism from estimation error. Because the main simulation doesn't fit models to sampled data, it doesn't show how finite-sample noise would change the reversal. The paper doesn't test multimodal inputs, so its suggestion for UA rests on the ECG-only results. The idea that phenotypes outside the ECG may need symptoms, biomarkers, or other clinical data remains untested in this study.

The breast-cancer example is offered as an extension and isn't evaluated in the experiments.

## Paper info

- **Authors**: Alexander Schubert, Anton Håkansson, Ziad Obermeyer
- **Venue**: arXiv · Preprint
- **First published**: 2026-11-8
- **Added**: 2026-11-10
- **Updated**: 2026-11-8
- **Version**: v1
- **arXiv**: 2611.11063
- **Category**: cs.LG · cs.AI
- **Original paper terms**: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/)
- **What we show**: Paper info, commentary and permitted figures from the original paper

[Original paper ↗](https://arxiv.org/abs/2611.11063v1) · [PDF ↗](https://arxiv.org/pdf/2611.11063v1)

AI commentary is a separate explanation from the original paper and may contain errors. The original paper and figures follow each source's terms of use and any rights noted separately.

## Abstract

Medical machine learning models often learn from diagnoses observed only in patients clinicians chose to test. The biases of such selective labels are well known, but less understood is what happens when a diagnosis includes cases the model's inputs cannot detect. Because testing decisions draw on information the model does not see, these cases can appear predictable among tested patients, producing relationships that fail, and can even reverse, among the untested. We formalize this mechanism and show in simulations that it worsens as testing becomes more selective or undetectable cases more common, while models trained only on detectable cases remain informative. We empirically study electrocardiogram (ECG)-based prediction of acute coronary syndrome (ACS), which is confirmed only by invasive testing and whose subtypes differ in how clearly they appear on the ECG. Three ECG foundation models fine-tuned on revascularization, our ACS proxy, performed well among catheterized patients (AUROC 0.740-0.770) but worse than chance for 30-day major adverse cardiovascular events among untested patients (AUROC 0.381-0.478). Models trained on ECG-visible subtypes retained discrimination (AUROC 0.680-0.709), whereas a model trained on unstable angina, which can occur without ECG changes, was inversely related to risk (AUROC 0.310). Under selective labels, effective learning therefore requires prediction targets that can be inferred from the model's inputs and evaluation in the intended deployment population, which often extends beyond the patients who were tested.

## Quote from the paper

Alexander Schubert, Anton Håkansson, Ziad Obermeyer (2026). Target Recoverability under Selective Labels: A Failure Mode in ECG-Based Acute Coronary Syndrome Prediction. arXiv:2611.11063v1. https://arxiv.org/abs/2611.11063v1

**BibTeX**

```
@misc{schubert2026target,
  title = {{Target Recoverability under Selective Labels: A Failure Mode in ECG-Based Acute Coronary Syndrome Prediction}},
  author = {Alexander Schubert and Anton Håkansson and Ziad Obermeyer},
  year = {2026},
  eprint = {2611.11063},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.11063v1}
}
```

## Other paper commentary

- [But It Was True When I Checked: Compiling SHOP-Style Method Preconditions into Partially-Ordered HTN Planning](https://refivu.com/en/papers/dfa127c3-d21a-4d60-a1c0-9b867b0008c3-but-it-was-true-when-i-checked-compiling.md)
- [Learning to Rank Propagators in Constraint Programming](https://refivu.com/en/papers/c113b866-d02f-420e-897f-5b5ecb0f1080-learning-to-rank-propagators-in-constraint-programming.md)
- [Pixels over Symbols: Sensory Realism Improves Behavioral Alignment in Models of Cognition](https://refivu.com/en/papers/f163388c-619b-4473-b0c2-357e1b91ea25-pixels-over-symbols-sensory-realism-improves-behavioral.md)
- [Guiding future global temperature distributions with simulations and observations](https://refivu.com/en/papers/0f0e0eec-05c1-4800-8206-66b04e61e097-guiding-future-global-temperature-distributions-with.md)
- [Beyond the Mean Gap: What Transferred-Angle QAOA Retains on a Superconducting Processor](https://refivu.com/en/papers/8f033d4e-6221-47eb-ba57-a9271b2927e9-beyond-the-mean-gap-what-transferred-angle-qaoa.md)
- [A Reduction of Imitation Learning and Structured Prediction to No-Regret Online Learning](https://refivu.com/en/papers/08306129-4598-48b6-baf3-9d1af09e03a6-a-reduction-of-imitation-learning-and-structured-prediction.md)
- [Think or Remember: The Exchange Rate of Agentic Inference](https://refivu.com/en/papers/430e6cf8-4d25-4ea8-8672-86be1d22daf9-think-or-remember-the-exchange-rate-of-agentic.md)
- [Identifiable alignment of unpaired representations](https://refivu.com/en/papers/d1142187-968e-4d40-b99f-8cc798e1c8a1-identifiable-alignment-of-unpaired-representations.md)
- [How to "train" a surgeon? Benchmarking generalist agents in surgical scene understanding](https://refivu.com/en/papers/c14fcb0f-7658-4cdb-aab2-a512b0b5e61c-how-to-train-a-surgeon-benchmarking-generalist-agents.md)
- [AbductionBench: Benchmarking Abductive Reasoning in Large Language Models](https://refivu.com/en/papers/5447aa31-8498-47e7-ac8b-ac02bc06c0bc-abductionbench-benchmarking-abductive-reasoning-in-large.md)
- [Machine Hearing: Can Audio LLMs Generalize Beyond Human Auditory Perception?](https://refivu.com/en/papers/0cabc2f0-42fb-4be8-9cca-d705df6b4273-machine-hearing-can-audio-llms-generalize-beyond-human.md)
- [Same Contacts, Different Rooms:Meeting Format Shapes LLM Group Influence Beyond Pairwise Contact Counts](https://refivu.com/en/papers/44bb6582-331e-4190-a4d5-2af78e6b5479-same-contacts-different-rooms-meeting-format-shapes-llm.md)

---

AI-written text can contain mistakes. [Refivu](https://refivu.com/en/papers/6be5f693-4010-4ca4-a6a8-74c4cb667334-target-recoverability-under-selective-labels-a-failure-mode)
