# MedPhysBench: A Benchmark for Evaluating Language Models on Medical Physics Calculations and Error Detection

MedPhysBench tests whether language models can check medical physics calculations

Omar Nusrat · arXiv · 2026-11-3

- **Problem** Language models have not been tested on medical physics calculations, where one error can affect every patient treated with it. Exam-style benchmarks grade a letter rather than a dose with its unit, and their reference labels can be wrong.
- **Method** MedPhysBench generates seeded items and grades answers against protocol code, not a model judge.
- **Results** Four of 12 models answered 99.3 to 100.0% of calculation items within tolerance. Claude Sonnet 5.5 omitted the inverse-square correction in 19 of 20 isocentric MU items.

![Figure 1: The three tasks built from one parameter draw, shown for a public development item (MU generator, level 3, seed 1). Each task is sent to the model as…](https://refivu.com/papers/8e140d70-2b40-4fed-80e5-c88449a660ed/figures/figure-ac034a9fe36252f327f4e319b04230b6.png?thumb=512)

**Figure 1** :The three tasks built from one parameter draw, shown for a public development item (MU generator, level 3, seed 1). Each task is sent to the model as a separate query. Checking tasks exist for five of the ten generators (TG-51, MU, NCRP 151, SSDE and MIRD); the other five give calculation items only. The worksheet check and the result check show the same candidate calculation, written by the generator; the candidate is either correct or carries one planted error. Here the inverse-square factor is left out at step 9, which raises the MU by 3.0%, outside the 1% band. Text set off by a colored rule is quoted from the prompts; the gray panels summarize the case and the grading and are not quoted. Nothing in the dashed panel (the reference answer, the grading criteria and a note for the reader) is shown to the model. A worksheet check’s primary criterion requires the verdict and the first incorrect step; the corrected result is recorded separately. Full prompts are in Section B.

[Original paper](https://arxiv.org/abs/2611.05340v1) · [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/) · Omar Nusrat · MedPhysBench: A Benchmark for Evaluating Language Models on Medical Physics Calculations and Error Detection · Original paper figure · Extracted the figure area from page 5 of the original PDF.

## Why standard tests miss calculation and checking

A wrong beam calibration keeps distorting the dose for every patient treated on that beam until someone measures it again. TG-114 asks for every MU calculation to be verified by a second calculation that uses an independent algorithm and data. Physicists also have a second physicist review plans and charts, so checking is built into the routine.

So a department weighing a model for drafting or checking an MU calculation needs evidence on exactly those two tasks.

A physicist's work also includes a judgment that a colleague's number is right, and a letter grade can't capture that either.

Score-calculation benchmarks have their own weakness, because their reference labels can be wrong. An audit with physician oversight flagged 27.3% of the test instances of one such benchmark as likely label errors. Medical physics has an advantage, since its protocols define each computation once every input and convention is stated. So a reference can come from code that implements the protocol instead of from a model's output.

MedPhysBench takes that route, computing every reference answer with such code and grading with a tolerance band.

## A protocol as the answer key

The key idea is that a protocol fixes every formula, so once every input and convention is written down, code that implements the protocol gives the reference answer. A grader converts units and applies a tolerance band, so no human or model judge is needed.

The generator then computes the reference answer with code that implements the governing protocol or report. Each generator has three levels, from level 1, where all data are printed and a solution takes one step for a dose-length product up to six for a single TG-43 dwell, to level 3, a complete hand calculation for a clinical task.

The calculation item asks for the quantity as a boxed value with its unit. The worksheet check shows numbered steps, half of them correct and half holding one planted error, and asks for a verdict, the first wrong step and a corrected result. The result check shows only the colleague's final number, so the same planted error has to be judged without its working.

A planted error must be visible, changing its own step's displayed result and moving the final result outside the band.

The two checking formats organize a check differently, one reviewing each step and the other recomputing the quantity and comparing it with the colleague's number. Neither is an independent check in the TG-114 sense, because the model still receives the inputs as given.

## How the grader scores responses and where the tolerance band comes from

The grader scores calculation items with deterministic rules and no model judge. Gray and sievert count as different quantities, so a dose reported in the wrong unit doesn't pass.

A correct calculation scores 1 when the checker judges it correct. A planted error in a worksheet check scores 1 only when the checker judges it incorrect and names the first wrong step. A planted error in a result check scores 1 when the checker judges it incorrect.

The band is a relative tolerance derived from the items, since no governing document sets one for an exact reference.

The result is 1% for most generators, 0.5% for TG-51, and 2% for radioactive decay. The TG-43 band was widened from the derived 1% to 2%, because level-3 solvers round source-to-point distances themselves. The band also limits what a final-answer grader can see, since it rejected errors according to their size relative to the band.

## Does the code match the protocols?

The authors checked the reference code against published worked examples, but only after the test runs. The MU code reproduced the four photon examples of TG-71 to within 0.3%. The NCRP 151 code reproduced all 20 transmissions, tenth-value layer counts and barrier thicknesses in four IAEA Safety Reports Series No. 47 examples to within 0.4%.

Reading NCRP Report 151 against the level-3 secondary-barrier items exposed two points where the items and the report differ. Four of the 20 level-3 test calculations are at 30°. The examples' value reflects an assumed distribution of gantry angles that the items don't give, so the angle alone doesn't fix the use factor.

The authors kept the frozen grading and regraded existing responses instead of collecting new ones. Twelve wrong calculation answers from six models follow the report, and accepting them would raise Gemini 4 Argon to 100.0% and GPT-6.1 Sol to 99.8%. The pairwise tests would still separate the same 51 of the 66 model pairs, so the groups in Figure 2 wouldn't change.

Beyond the worked examples, the authors tested the grader with acceptance tests and negative controls. The grader accepted the generator's own reference answer on all 15,000 items tested, and all 3,000 regenerated items matched byte for byte. A constant answer passed at most 8% of items in most generator and level cells, but it passed 29% of level-3 TG-51 items because that output varies so little.

The pilot traced every failure of the three strongest models by hand, and the authors fixed four benchmark defects found that way.

## Where models fail on calculation

Twelve models were scored on the calculation items of the MedPhysBench test split, and four of them reached the ceiling. GPT-6 Astra, GPT-6.1 Sol, Gemini 4 Argon and Claude Opus 5.5 answered 99.3 to 100.0% of calculation items within tolerance. Exact McNemar tests between every pair of models, with Holm's adjustment over all 66 pairs, didn't separate any two of these four.

Six harder problems that the authors wrote during design didn't separate Claude Opus 5.5 and GPT-6.1 Sol either.

The authors read all nine answers that the four ceiling models got wrong, and the grader had marked each one incorrect.

For the other eight models, failures concentrate in level-3 items, and accuracy is lowest there for every model except Claude Fable 5.1. Claude Fable 5.1's failures were mostly blocked or interrupted responses rather than wrong numbers. On the level-3 TG-51 worksheet, Claude Sonnet 5.5, GPT-6 Luna, DeepSeek V4 Pro and Mistral Large 3 scored 5 to 13 of 20.

Claude Sonnet 5.5 omitted the isocentric inverse-square correction in 19 of the 20 isocentric MU items. That correction is needed because the output is specified at dmax for SSD 100cm, so omitting it raises the MU by 3.0 to 6.5%. Five of those responses state that an isocentric setup needs no such correction, while the other 14 never mention one.

At high reasoning effort, the model solved 6 of 20 isocentric MU items, and all 14 of its remaining wrong answers still omitted the correction. So the error is systematic for this model rather than scattered noise.

## Detection and false alarms in checking

Those draws use seeds 20,000 to 21,999, which are disjoint from the test seeds. It flagged 5% of the correct results, with a 2 to 10% interval, which the authors read as close to the nominal 5%. A checker that never calculates already catches over a third of these planted errors, so a model has to clear that bar.

Showing only the result made six of the other seven models raise more false alarms than when they saw the worksheet. Holm's adjustment over all 24 comparisons kept the increase significant for four models. gpt-oss-20b flagged 38.7% of correct results in the result-only format, against 5.3% of correct worksheets.

A recomputation can share the colleague's misconception, so a result check doesn't guarantee a catch. Claude Sonnet 5.5 accepted all 20 wrong results in the targeted test, and Claude Opus 5.5 sometimes dropped a correction its own calculations applied. For this reason TG-114 and TG-219 recommend a second check with its own algorithm and data, which these checking formats don't provide.

## A targeted test of one omitted correction

After the main evaluation, the authors designed an exploratory test around one error, the omitted isocentric inverse-square correction. Leaving out the factor raised the MU by 3.0 to 6.5% across the sets, with the factor defined as ((100 cm + dmax)/100 cm)², the calibration at dmax for SSD 100 cm.

![Figure 4: Calculation and checking diverge on a controlled inverse-square omission. This targeted test of one error mechanism is exploratory and was chosen aft…](https://refivu.com/papers/8e140d70-2b40-4fed-80e5-c88449a660ed/figures/figure-e15cc121851fc64a7728422b70580707.png?thumb=512)

**Figure 4** :Calculation and checking diverge on a controlled inverse-square omission. This targeted test of one error mechanism is exploratory and was chosen after the main evaluation; it estimates neither how often the error occurs nor checking performance in general. Twenty public parameter sets of the level-3 isocentric MU calculation were each presented five times: as the calculation, as a worksheet check and a result check carrying the omission, and as a correct worksheet and a correct result. The upper three models are the models at the ceiling that answered the full test split; the lower three were chosen for their accuracy on the isocentric MU items of the test split (Claude Sonnet 5.5 1/20, GPT-6 Luna 15/20, gpt-oss-120b 6/20). The left box is the reference calculation, which no model sees; the right box is the planted error. Points are counts of 20 with exact 95% intervals. (a) Correct calculations. (b) Planted omissions judged incorrect. (c) Correct calculations judged incorrect. Annotations come from the per-item records; 5 of Claude Opus 5.5’s 6 false alarms in result checks proposed the MU without the correction.

[Original paper](https://arxiv.org/abs/2611.05340v1) · [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/)

The three models at the calculation ceiling caught the omission in every planted worksheet.

Five of its six false alarms in result checks proposed the MU without the correction. So a model can know the correction and still drop it when it checks a result it didn't compute itself.

## What the results do not yet cover

The items are text only, and every input appears in the prompt. The protocols are North American, so the benchmark uses TG-51 rather than the IAEA code of practice.

Only 22 of 150 planted errors are smaller than 5%, so the checks say little about subtle slips. That happens in 17% and 14% of planted worksheets in public draws, so a checker can spot a missing step. The two-source rule and the unstated use factor in the level-3 NCRP 151 items still depart from NCRP Report 151, so some answers graded incorrect follow the report.

Each model answered each item once, with provider defaults and without tools. The five least expensive models answered the whole test split a second time, and they scored 1.0 to 3.5 points lower on calculation. Two models answered only half of the test split, and the budget limited the panel.

Seven test items omitted the reported quantity from the result-check prompt, so a correct number of a different quantity was graded. The authors didn't preregister the analyses, and the targeted test and the NCRP 151 regrade came after they saw the results. Version 1.1 will add the quantity to the prompt and correct the shielding items.

## Paper info

- **Authors**: Omar Nusrat
- **Venue**: arXiv · Preprint
- **First published**: 2026-11-3
- **Added**: 2026-11-6
- **Updated**: 2026-11-3
- **Version**: v1
- **arXiv**: 2611.05340
- **Category**: physics.med-ph · cs.AI · cs.CL
- **Original paper terms**: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/)
- **What we show**: Paper info, commentary and permitted figures from the original paper

[Original paper ↗](https://arxiv.org/abs/2611.05340v1) · [PDF ↗](https://arxiv.org/pdf/2611.05340v1)

AI commentary is a separate explanation from the original paper and may contain errors. The original paper and figures follow each source's terms of use and any rights noted separately.

## Abstract

Medical physicists turn a prescription into a delivered dose and check one another's calculations, because one error in a beam calibration or a monitor-unit (MU) calculation can affect every patient treated with it. MedPhysBench has ten seeded generators of calculation items in radiation therapy, diagnostic imaging, nuclear medicine and radiation protection, up to clinical tasks such as a TG-51 calibration worksheet. Reference answers come from code implementing the governing protocols, and a grader converts units and applies tolerance bands. From the same inputs, separate checking items test error detection, showing a colleague's worksheet or only the colleague's result, half correct and half with one planted error. On a held-out test split of 1,200 items (half for two models), 12 models scored 33.3 to 100.0% on calculation. Of the nine answers graded incorrect for the four best (99.3-100.0%), five contained model errors and four followed NCRP Report 151 on points our items misstate or leave open. Below them, most models did worst on level-3 clinical tasks, and Claude Sonnet 5.5 omitted the inverse-square correction in 19 of 20 isocentric MU items. Five models detected at least 96.7% of mostly large planted errors with at most 4% false alarms; for four of the other seven, checking only the result raised false alarms significantly. In an exploratory targeted test with 20 public cases of an omitted inverse-square correction, the three best models tested caught it in every worksheet, and three weaker models accepted 16 to 18 of 20 planted worksheets, one of them while applying the correction in most of its own calculations. Claude Opus 5.5 accepted 6 of 20 wrong results, although it applied the correction in all 20 of its own. We report the effect of two problems in our shielding items, found after the runs, and release the code, per-item outcomes and targeted-test responses.

## Quote from the paper

Omar Nusrat (2026). MedPhysBench: A Benchmark for Evaluating Language Models on Medical Physics Calculations and Error Detection. arXiv:2611.05340v1. https://arxiv.org/abs/2611.05340v1

**BibTeX**

```
@misc{nusrat2026medphysbench,
  title = {{MedPhysBench: A Benchmark for Evaluating Language Models on Medical Physics Calculations and Error Detection}},
  author = {Omar Nusrat},
  year = {2026},
  eprint = {2611.05340},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.05340v1}
}
```

## Other paper commentary

- [When Cell Crops Share a Parent: Measuring and Isolating Acquisition Leakage in Cervical Cytology Benchmarks](https://refivu.com/en/papers/951878ef-19be-4cc9-9d98-97a0e43bd9cb-when-cell-crops-share-a-parent-measuring-and.md)
- [XDecideBench: Evaluating Typed Decision Models and Confidence Policies Across Languages](https://refivu.com/en/papers/049194cb-43e0-4de8-8af2-c4f41dd6c424-xdecidebench-evaluating-typed-decision-models-and-confidence.md)
- [Puzzling-Bench: Evaluating Language Models on 23,777 Human-Written Puzzles with Community-Verified Answers](https://refivu.com/en/papers/1b9641d7-d6fa-4ead-8f16-7134498580d3-puzzling-bench-evaluating-language-models-on-23-777.md)
- [Refusal Is Not Scored: A Coverage Limit in Content-Based Bias Evaluation](https://refivu.com/en/papers/d282d82d-de6e-498c-898b-66902724ac0d-refusal-is-not-scored-a-coverage-limit-in.md)
- [OWE-Bench: A long-horizon benchmark for measuring real-world engineering](https://refivu.com/en/papers/7bf5dadf-998c-4908-8782-37501a593ad5-owe-bench-a-long-horizon-benchmark-for-measuring.md)
- [Diagnostic Accuracy Is Not Deployment Value: Decision-Aligned Reliability Evaluation for Foundation MLIPs in Materials Discovery](https://refivu.com/en/papers/1fbe0ca2-cd2b-42b0-94f7-4e5e37ccbb85-diagnostic-accuracy-is-not-deployment-value-decision-aligned.md)
- [Personas Are Not People: Identity as State, Not Attribute](https://refivu.com/en/papers/9138858c-ab78-4e20-ae09-ef713b23e52d-personas-are-not-people-identity-as-state-not.md)
- [Should the Action Expert Train the VLM? Action-Token Supervision and Gradient Routing in Mixture-of-Transformer VLAs](https://refivu.com/en/papers/12ec7add-9da8-4e57-b871-1f4a8b56ec14-should-the-action-expert-train-the-vlm-action.md)
- [Knowingly Wrong: Training LLMs Against Their Own Beliefs can Induce Misalignment](https://refivu.com/en/papers/69fc0571-e9b6-410b-9f8d-1ccfc18e22af-knowingly-wrong-training-llms-against-their-own-beliefs.md)
- [Provably Learning Mixtures of Linear Experts](https://refivu.com/en/papers/a693512b-12da-400e-ac5f-bac72adad88e-provably-learning-mixtures-of-linear-experts.md)
- [What Does the Model See? Representation Validity in Multimodal LLM-Based Video Analysis](https://refivu.com/en/papers/aa9db505-45a3-4ffc-8853-8136deb101cb-what-does-the-model-see-representation-validity-in.md)
- [LoopQ: Fair, Closed-Loop Evaluation of Quantized Vision-Language-Action Models](https://refivu.com/en/papers/fddc7dd0-8d8e-4fad-bedf-d537357790eb-loopq-fair-closed-loop-evaluation-of-quantized-vision.md)

## Terms in this paper

- [generator](https://refivu.com/en/terms/2935313c9c21-generator)
- [Detection](https://refivu.com/en/terms/c7b79c4839be-detection)
- [tolerance band](https://refivu.com/en/terms/b1f709074cee-tolerance-band)

---

AI-written text can contain mistakes. [Refivu](https://refivu.com/en/papers/8e140d70-2b40-4fed-80e5-c88449a660ed-medphysbench-a-benchmark-for-evaluating-language-models-on)
