# MultiResUNet : Rethinking the U-Net Architecture for Multimodal Biomedical Image Segmentation

Multi-scale blocks and residual paths make U-Net more robust on medical images

Nabil Ibtehaz, M. Sohel Rahman · arXiv · 2019-2-11

- **Problem** U-Net uses the same pair of 3×3 convolutions at every stage, so it has no explicit way to read several scales. Its skip connections also may join encoder and decoder features that do not match well.
- **Method** MultiResUNet replaces each U-Net convolution pair with a MultiRes block of stacked 3×3 layers and a residual connection. It also swaps plain skip connections for Res paths of convolution blocks.
- **Results** On ISIC-2018 dermoscopy under 5-fold cross-validation, it reached 80.2988 Jaccard Index against 76.4277 for U-Net, a relative improvement of 5.065.

## Why U-Net needs changing

U-Net segments medical images well, yet every stage of its encoder and decoder is built from the same pair of 3×3 convolutions. The structures to segment, such as skin lesions in dermoscopy images, differ greatly in size, and a fixed stack of small kernels offers no explicit way to read several scales at once. The authors argue that a network for medical images has to cope with objects at different scales, and they note that medical segmentation has not yet handled this point well.

A second concern lies in the skip connections, which join early encoder features to decoder features computed much deeper in the network. The authors suspect a semantic gap between the two sets: encoder features are low-level, decoder features are high-level, and fusing them directly may disturb learning. This gap is framed as a conjecture, and the later design choices are meant to test it.

## How the U-Net baseline is built

The encoder repeats a block of two 3×3 convolutions followed by 2×2 max pooling with stride 2, four times, and the filter count doubles after each downsampling. Two more 3×3 convolutions sit at the bottom, between the encoder and the decoder.

Each decoder stage upsamples with a 2×2 transposed convolution that halves the channel count and then applies two 3×3 convolutions. The chain ends with a 1×1 convolution, with ReLU in every convolution except the last and a Sigmoid output.

Before each pooling step, the encoder output is sent to the decoder, where it is concatenated with the upsampled features. This lets the network recover spatial detail that pooling discards.

## The MultiRes block

The starting point is an Inception-like block in which 3×3, 5×5 and 7×7 convolutions run in parallel on the same input and their feature maps are concatenated. This is the simplest route to multi-resolution analysis in U-Net, but parallel large kernels increase memory use considerably.

To reduce the cost, the 5×5 and 7×7 branches are replaced by chains of 3×3 convolutions, where the second and third 3×3 layers stand in for the 5×5 and 7×7 receptive fields. The outputs of the three 3×3 layers are concatenated, and the authors report that this compact form performed close to the Inception-like block in their experiments.

The block also increases the filter count gradually across its three layers and adds a residual connection with a 1×1 convolution. The reasoning is that the filter count of the first of two stacked layers has a quadratic effect on memory, so keeping the filters even would push the memory cost of the early layers into the deeper network.

## Res paths and the semantic gap

A Res path sends the encoder feature maps through a chain of convolution layers, each with a residual connection, before they are concatenated with the decoder features. Its 3×3 filters are paired with 1×1 filters on the residual connections.

The added nonlinear processing is meant to narrow the mismatch between encoder and decoder features. The authors also avoid pooling inside this path, since they take the point from an earlier image-to-image work that pooling loses information.

The number of convolution blocks drops along the four Res paths, with 4, 3, 2 and 1 blocks, and the filter counts are 32, 64, 128 and 256. The reasoning is that the mismatch should shrink toward the inner paths, so the inner paths need less processing.

## Assembling MultiResUNet

Each MultiRes block receives a width parameter W, defined from the filter count U of the matching U-Net level, where U takes the values 32, 64, 128, 256 and 512. \\\[ W = \\alpha \\times U \\\] The scaling coefficient α is fixed at 1.67, chosen so that the total parameter count stays slightly below that of U-Net.

Inside a block, the three successive layers receive \\(\\lfloor W/6 \\rfloor\\), \\(\\lfloor W/3 \\rfloor\\) and \\(\\lfloor W/2 \\rfloor\\) filters, which the authors report as the combination that gave the best results in their experiments. As in U-Net, W doubles after each pooling or deconvolution step.

Every convolution except the output layer uses ReLU and batch normalization, and the output layer uses Sigmoid. The original U-Net did not use batch normalization. Since W and α are design constants set before training, the model is one fixed configuration rather than one that takes these settings as run-time inputs.

## Five 2D datasets and one 3D dataset

The study covers five 2D datasets from four 2D modalities and one 3D MRI dataset, chosen to differ from each other as much as possible. Each dataset is given a different challenge, from debris and bright outliers to vague boundaries and a foreground that fills most of the image.

The Murphy Lab fluorescence set has 97 images containing 4009 cells, half U2OS and half NIH3T3, with nuclei segmented manually, and the images were resized to 256×256. The ISBI-2012 electron microscopy set has 30 ssTEM images of the Drosophila first instar larva ventral nerve cord, resized from 512×512 to 256×256. In that set the region to segment covers most of the image.

The ISIC-2018 dermoscopy set has 2594 images, resized to 256×192. The CVC-ClinicDB endoscopy set has 612 polyp images taken from 29 colonoscopy video sequences, resized to 256×192. The BraTS17 MRI set has 210 HGG and 75 LGG scans, with four channels (T1, T1Gd, T2 and FLAIR), resized from 240×240×155 to 80×80×48.

## Training and scoring protocol

Segmentation is treated as pixelwise binary classification, and the loss is a binary cross-entropy summed over the pixels of each image and averaged over the images in a batch. \\\[ \\mathrm{CrossEntropy}(X,Y,\\hat{Y}) = \\sum\_{p\_x \\in X} -\\big(y\_{p\_x}\\log \\hat{y}\_{p\_x} + (1-y\_{p\_x})\\log(1-\\hat{y}\_{p\_x})\\big) \\\] \\\[ J = \\frac{1}{n}\\sum\_{i=1}^{n} \\mathrm{CrossEntropy}(X\_i, Y\_i, \\hat{Y}\_i) \\\]

All models are trained with Adam, using its default parameters from the original paper, for 150 epochs. The authors chose 150 epochs because neither model showed further improvement after that point. Input pixel values are divided by 255, and the Sigmoid output is thresholded at 0.5, with no domain-specific pre- or post-processing.

The Jaccard Index is the intersection over union of the ground truth mask A and the predicted mask B. \\\[ \\text{Jaccard Index} = \\frac{A \\cap B}{A \\cup B} \\\] Precision and recall can look high when background dominates, while the Jaccard Index also penalizes under- and over-segmentation.

Each dataset is split randomly into five mutually exclusive subsets, and each subset serves once as the validation set. For every fold, the best validation score reached over the 150 epochs is recorded, and the five fold results are then combined. Because the best epoch is picked on the validation split, the reported scores are selected on that split.

## Five-dataset comparison with U-Net

On dermoscopy, MultiResUNet reached 80.2988 ± 0.3717 against 76.4277 ± 4.5183 for U-Net, a relative improvement of 5.065. On endoscopy, the figures are 82.0574 ± 1.5953 against 74.4984 ± 1.4704, a relative improvement of 10.1465.

On fluorescence microscopy, the model scored 91.6537 ± 0.9563 against 89.3027 ± 2.1950 for U-Net, a relative improvement of 2.6326. On MRI, the scores are 78.1936 ± 0.7868 against 77.1061 ± 0.7768, a relative improvement of 1.4104. The fluorescence result is obtained with fewer parameters than U-Net.

On electron microscopy, the two models are close: 87.9477 ± 0.7741 against 87.4092 ± 0.7071, a relative improvement of 0.6161. The largest gains appear on dermoscopy and endoscopy, which the authors describe as less uniform images, and the spread across folds is much wider for U-Net on dermoscopy than for MultiResUNet.

## Convergence speed over epochs

The validation Jaccard Index was recorded after every epoch in each fold and is plotted per dataset. The authors report that MultiResUNet converges faster across the cases, and on electron microscopy it starts below U-Net before overtaking it.

The authors attribute the faster convergence to the combination of residual connections and batch normalization, citing earlier work. This explanation is the authors' interpretation, and the text does not measure its contribution separately.

Apart from minor fluctuations, the standard deviation across folds is smaller for MultiResUNet, which the authors read as a sign of reliability.

## Behaviour on hard images

On one polyp with a clearly visible boundary, U-Net reached a Jaccard Index of 0.9678 and MultiResUNet 0.9697, a small difference.

For polyps with vague boundaries, the authors describe U-Net as under-segmenting or over-segmenting, while MultiResUNet gives masks closer to the polyp. These are shown as selected examples, and the text gives no aggregate score for them.

On dermoscopy with perturbations, U-Net sometimes returns scattered fragments for a foreground object, adds false foreground on a rough background, or misses the object when contrast is low. The authors conjecture that the extra nonlinear processing on encoder feature maps gives robustness against such perturbations, and an earlier version without Res paths was also affected.

In fluorescence microscopy, some bright particles resemble nuclei, and U-Net labels some of them as nuclei while MultiResUNet rejects them.

## The majority-class case

In the electron microscopy data the foreground is most of the image, with thin background membranes between regions. The text suggests that models over-segment such images to lower the training loss.

The MultiResUNet mask reaches a Jaccard Index of 0.8914 and the U-Net mask 0.8841, though the masks differ visually. The MultiResUNet mask keeps more of the thin separating lines that U-Net misses, and it finds some small background clusters that U-Net largely drops.

The authors argue that the Jaccard Index is inflated when the foreground is the majority class, so it is a weak measure of accuracy here. For this reason the gain on this dataset looks small in the metric, though the segmentations are more accurate visually.

## The 3D variant and the parameter budget

The 3D MultiResUNet replaces the 2D convolution, pooling and transposed convolution layers with their 3D counterparts, without other changes. The 3D U-Net baseline follows the original 3D U-Net design, and the four MRI channels are used as input channels.

The 2D MultiResUNet has 7,262,750 parameters against 7,759,521 for the 2D U-Net baseline. The 3D MultiResUNet has 18,657,689 parameters against 19,078,593 for the 3D U-Net baseline.

The authors state that the 3D MultiResUNet performs better than the 3D U-Net on BraTS17. The text gives no 3D score, so the size of this gain cannot be read from it.

## Limits of the evidence

The segmentations produced by MultiResUNet are not perfect, and the authors say they outperform U-Net in most cases rather than in all.

The hyperparameter search was not exhaustive, and the authors leave a broader search to future work. Other modalities and domain-specific pre- and post-processing are listed as future directions and were not tested.

Training stops at 150 epochs and the reported fold scores are best validation values, so the comparison reflects that protocol. The text gives no separate numerical ablation of the MultiRes block or the Res path, and their effects are argued from whole-model comparisons and qualitative examples.

## Paper info

- **Authors**: Nabil Ibtehaz, M. Sohel Rahman
- **Venue**: arXiv · Preprint
- **First published**: 2019-2-11
- **Added**: 2026-11-12
- **Updated**: 2019-2-11
- **Version**: v1
- **arXiv**: 1902.04049
- **DOI**: 10.1016/j.neunet.2019.08.025
- **Category**: cs.CV
- **Original paper terms**: [arXiv non-exclusive 1.0](https://arxiv.org/licenses/nonexclusive-distrib/1.0/)
- **What we show**: Paper info and commentary

[Original paper ↗](https://arxiv.org/abs/1902.04049v1) · [PDF ↗](https://arxiv.org/pdf/1902.04049v1)

AI commentary is a separate explanation from the original paper and may contain errors. The original paper and figures follow each source's terms of use and any rights noted separately.

## Quote from the paper

Nabil Ibtehaz, M. Sohel Rahman (2019). MultiResUNet : Rethinking the U-Net Architecture for Multimodal Biomedical Image Segmentation. arXiv:1902.04049v1. https://doi.org/10.1016/j.neunet.2019.08.025

**BibTeX**

```
@article{ibtehaz2019multiresunet,
  title = {{MultiResUNet : Rethinking the U-Net Architecture for Multimodal Biomedical Image Segmentation}},
  author = {Nabil Ibtehaz and M. Sohel Rahman},
  year = {2019},
  eprint = {1902.04049},
  archivePrefix = {arXiv},
  doi = {10.1016/j.neunet.2019.08.025},
  url = {https://arxiv.org/abs/1902.04049v1}
}
```

## Other paper commentary

- [MLP-Mixer: An all-MLP Architecture for Vision](https://refivu.com/en/papers/bf0a9095-e638-4ae5-bab6-5abf2b479763-mlp-mixer-an-all-mlp-architecture-for-vision.md)
- [SemanticKITTI: A Dataset for Semantic Scene Understanding of LiDAR Sequences](https://refivu.com/en/papers/304a0de8-6214-4d64-8649-0176464fb2d4-semantickitti-a-dataset-for-semantic-scene-understanding-of.md)
- [Real-world Anomaly Detection in Surveillance Videos](https://refivu.com/en/papers/dd2c7247-4d8f-4a7a-8400-f4e9c8e74dca-real-world-anomaly-detection-in-surveillance-videos.md)
- [RandLA-Net: Efficient Semantic Segmentation of Large-Scale Point Clouds](https://refivu.com/en/papers/5d37c138-f524-49a6-ba5e-e9ff9f584cdd-randla-net-efficient-semantic-segmentation-of-large-scale.md)
- [Pre-Trained Image Processing Transformer](https://refivu.com/en/papers/8475de2d-12d6-41b5-8348-16c772598a34-pre-trained-image-processing-transformer.md)
- [Soft-NMS -- Improving Object Detection With One Line of Code](https://refivu.com/en/papers/d6a13a67-cb33-4ee3-8420-05da2f2b5960-soft-nms-improving-object-detection-with-one-line.md)
- [Multimodal Transformer for Unaligned Multimodal Language Sequences](https://refivu.com/en/papers/022f0bed-e82b-408d-a49e-8805e4f212e5-multimodal-transformer-for-unaligned-multimodal-language.md)
- [Obfuscated Gradients Give a False Sense of Security: Circumventing Defenses to Adversarial Examples](https://refivu.com/en/papers/6d5ee375-978f-4c78-87e2-0c8e55a1127f-obfuscated-gradients-give-a-false-sense-of-security.md)
- [Practical recommendations for gradient-based training of deep architectures](https://refivu.com/en/papers/0f41024c-5358-4bc2-be1e-7190db5f4d0c-practical-recommendations-for-gradient-based-training-of.md)

## Terms in this paper

- [Batch Normalization](https://refivu.com/en/terms/2b3e5f8509f6-batch-normalization)
- [Semantic segmentation](https://refivu.com/en/terms/00dfce7ec404-semantic-segmentation)
- [ReLU](https://refivu.com/en/terms/7b22f5612f6c-relu)
- [Adam optimizer](https://refivu.com/en/terms/aff9e901333e-adam-optimizer)
- [max pooling](https://refivu.com/en/terms/5fb6ec0ed2d6-max-pooling)
- [skip connections](https://refivu.com/en/terms/8c8a0a5eff69-skip-connections)
- [residual connection](https://refivu.com/en/terms/fc7be70d6007-residual-connection)
- [transposed convolution](https://refivu.com/en/terms/5345831f54b4-transposed-convolution)
- [binary cross-entropy](https://refivu.com/en/terms/bbec6d1b6dde-binary-cross-entropy)
- [Jaccard Index](https://refivu.com/en/terms/c2a7049ebc65-jaccard-index)
- [k-fold cross-validation](https://refivu.com/en/terms/0ad05af8de0e-k-fold-cross-validation)
- [medical image segmentation](https://refivu.com/en/terms/96ad294cdaad-medical-image-segmentation)
- [3D u-net](https://refivu.com/en/terms/3fc23b408107-3d-u-net)
- [CVC-ClinicDB](https://refivu.com/en/terms/09c033c0d734-cvc-clinicdb)

---

AI-written text can contain mistakes. [Refivu](https://refivu.com/en/papers/e99144f0-6aca-4598-b66e-67a4575f7fe4-multiresunet-rethinking-the-u-net-architecture-for)