Profile

Settings

Loading…

← Papers

Help

FAQ

Which features require signing in?

You can read the commentary, paper info, Model Structure and related papers of public papers without signing in. Sign in to manage your account or contact us about your inquiries.

Can I upload a PDF file?

Upload papers with an arXiv or DOI link; the commentary is public to everyone. Papers whose source and terms of use can't be verified, so the commentary can't be made public, can't be uploaded. Uploading PDF files and keeping papers private are for subscribers only, and a paper uploaded as a file is saved as private only. Searching for official info by title runs only when you press the button.

Are the figures and AI commentary accurate?

Figures come only from the original paper, and only those whose terms of use are verified are shown. The commentary is written by AI and may be wrong. Check important claims, numbers and figure context against the evidence in the original paper.

I want to report a copyright issue.

Terms of use and the source of the original paper are on the Paper info tab. If there's a problem, choose "Paper content, figures and copyright" under Contact us and send the paper link, the part in question, and evidence that you hold the rights. Receiving your report doesn't confirm any rights or remove anything right away. You can see the result of the review under My inquiries.

I forgot my password.

If you signed up with email, use Forgot password in the sign-in window to reset it with your verified email. If you signed up with Google, Naver or Kakao, change your password with that service.

What should I include in an inquiry?

Tell us which screen you were on and what you were doing when the problem happened, along with the paper link. Don't include personal information such as passwords, API keys, verification codes or phone numbers. Inquiries and replies are stored in Refivu and you can see them under My inquiries.

How do I delete my account?

In Settings, under My account, press Delete account. Review what will be deleted and complete identity verification to delete your account. For other requests, choose "Account" under Contact us.

Paper commentary

SimCVD: Simple Contrastive Voxel-Wise Representation Distillation for Semi-Supervised Medical Image Segmentation

  • Problem Voxel-wise segmentation of medical volumes needs many labeled scans, and semi-supervised methods lose robustness and boundary accuracy when labels are scarce.
  • Method Trains a student and a mean teacher on two dropout-masked, boundary-aware views of each volume, contrasting them with an InfoNCE loss. Adds signed distance map supervision and a pair-wise voxel similarity term.
  • Results Reached 90.85 Dice with 20% labeled LA scans and 89.03 Dice with 10%, against 89.94 and 87.49 for the best listed prior methods.

Figure 3: Visual comparisons with other methods on the pancreas dataset. We train all the evaluated methods in the setting of 12 annotated images.
Red and blue…

Fig. 3 . Visual comparisons with other methods on the pancreas dataset. We train all the evaluated methods in the setting of 12 annotated images. Red and blue denotes the predictions and ground truths, respectively.

Original paper · CC BY 4.0 · Chenyu You, Yuan Zhou, Ruihan Zhao, Lawrence Staib, James S. Duncan · SimCVD: Simple Contrastive Voxel-Wise Representation Distillation for Semi-Supervised Medical Image Segmentation · Original paper figure · Extracted the figure area from page 6 of the original PDF.

Why scarce labels hurt voxel-wise segmentation

Semi-supervised methods combine a few labeled volumes with many unlabeled ones, and contrastive learning has recently drawn attention for learning representations from little supervision.

The authors list three weaknesses of current approaches: semi-supervised models are less robust than fully supervised ones, they capture object geometry poorly so contours are hard to recover, and they overfit when training data is limited.

The study asks whether a contrastive objective built on dropout-masked views can improve voxel-wise segmentation when labeled scans are very few. Predicting signed distance maps targets the geometry gap, and distilling pair-wise voxel similarities targets the structural side of the problem.

Dropout-masked views as positive pairs

SimCVD follows the mean-teacher setup: a student and a teacher network each receive a perturbed copy of the same volume and each outputs a probability map and a signed distance map. The two copies differ by an affine transformation and a random crop.

The boundary-aware feature adds the input volume to the predicted distance map, so intensity and distance information enter one feature, as \( Q^{s,ba}_i = X_i + Q^{s,sdm}_i \) for the student. Each boundary-aware feature passes through the projection head under its own independent dropout mask, and the two resulting vectors form a positive pair.

The projection head applies alpha dropout, adaptive average pooling and a three-layer MLP to every 2D slice, so each slice becomes one feature vector. The same slice location in the two views is a positive, while slices at other locations or from other inputs are negatives.

For a teacher vector, the InfoNCE term takes the negative log of its softmax score for the matching student vector, with temperature \( \tau \), against all student vectors in the batch: \[ \mathcal{L}(h^t_{i,j}, h^s_{i,j}) = -\log \frac{\exp(h^t_{i,j}\cdot h^s_{i,j}/\tau)}{\sum_{k,l}\exp(h^t_{i,j}\cdot h^s_{k,l}/\tau)} \]

The boundary-aware contrastive loss averages this term in both directions over all positive slice pairs from the unlabeled volumes. \[ \mathcal{L}_{contrast} = \frac{1}{|\mathcal{N}^+|}\sum_{(i,j)\in\mathcal{N}^+}\left[\mathcal{L}(h^t_{i,j},h^s_{i,j})+\mathcal{L}(h^s_{i,j},h^t_{i,j})\right] \] Negatives come from a mini-batch sampling B 2D slices, and no large memory bank is used.

Segmentation and distance-map outputs

The backbone is V-Net, with an encoder and a decoder in each network. The classification branch outputs a probability map in [0,1], and the regression branch outputs a signed distance map in [-1,1] through a hyperbolic tangent.

A signed distance map is positive or negative according to whether a voxel lies inside the object, and its magnitude is the distance to the boundary. Ground-truth distance maps are computed from the labels.

For labeled volumes, the supervised loss combines a segmentation loss, which is Dice plus cross-entropy, with a mean squared error term on the distance map, weighted by a hyperparameter α. The authors impose the distance loss as a geometric constraint during training.

Teacher updates and the total objective

At each iteration the student is updated by stochastic gradient descent, and then the teacher weights are set to an exponential moving average of the student weights. The EMA decay rate is 0.999, taken from the setting of UA-MT.

The total objective adds the supervised loss to three unsupervised terms, each with its own coefficient: \[ \mathcal{L} = \mathcal{L}_{sup} + \lambda\mathcal{L}_{contrast} + \beta\mathcal{L}_{pd} + \gamma\mathcal{L}_{con} \] The coefficients α, λ, β, γ and τ are given as 0.1, 0.5, 0.1, 0.1 and 0.5, in that order.

The unsupervised weight is ramped up over training with a time-dependent Gaussian function of the current step t and the maximum step t_max: \[ \Psi_{con}(t) = \exp\left(-5(1-t/t_{max})^2\right) \]

At test time the mean teacher and the two projection heads are removed, and only the student network produces segmentations.

Pair-wise voxel similarity and consistency

The pair-wise term uses flattened encoder features from the teacher and the student on each unlabeled volume, and compares each voxel's cosine similarities with the voxels of the teacher feature map. \[ \mathcal{L}_{pd} = -\frac{1}{M}\sum_{i=N+1}^{N+M}\sum_{j=1}^{H'W'D'}\log\frac{\exp(s(v^s_{i,j},v^t_{i,j}))}{\sum_k\exp(s(v^s_{i,j},v^t_{i,k}))}, \quad s(v_1,v_2)=\frac{v_1\cdot v_2}{\|v_1\|\|v_2\|} \]

The authors motivate this term as complementary to the slice-level contrast, aimed at spatial labeling consistency between voxels.

The consistency term is a mean squared error between the student and teacher outputs, each computed on an unlabeled volume with added noise. \[ \mathcal{L}_{con} = \frac{1}{M}\sum_{i=N+1}^{N+M}\mathcal{L}_{mse}\left(F_s(X^s_i+\eta^s_i),F_t(X^t_i+\eta^t_i)\right) \]

Left Atrium results at 20% and 10% labels

The authors describe this as comparable to the fully supervised V-Net trained on 80 labeled scans, which scored 91.14 Dice.

The strongest listed prior method in that setting is DTC, at 87.49 Dice.

The authors attribute the gains to three factors: contrastive learning on voxel embeddings, pair-wise spatial consistency, and the SDM geometric constraint. The ablations test each of these factors separately.

The compared scores are published results of those methods rather than a shared re-run, so training protocols are not controlled across rows.

Pancreas CT results

The pancreas split uses 62 training scans, and the authors describe the setting as the 20% labeled ratio. Of these, 12 are labeled and 50 are unlabeled.

SimCVD reached 75.39 Dice and 61.56 Jaccard, with ASD 2.33 and 95HD 9.84 voxels, against 74.07 Dice for DTC, the best listed prior method. The fully supervised V-Net trained on 62 scans scored 77.84 Dice in the same table.

The authors report up to a 6.72% absolute Dice improvement over the compared methods.

Removing components on LA at 10%

The ablations use LA with 10% labels, and the full model reaches 89.03 Dice, 80.34 Jaccard, 2.59 ASD and 8.34 95HD.

Removing the SDM (SimCVD w/o SDM) lowers Dice to 88.24 and Jaccard to 79.07, and raises ASD to 4.19 and 95HD to 11.43, which are worse because lower values are better for both boundary metrics. The authors read this as evidence that the learned boundary-aware representations help segmentation.

Removing the contrastive term (SimCVD w/o Lcontrast) gives 85.13 Dice and 74.57 Jaccard, a 3.90-point Dice gap from the full model. Removing both the contrastive and pair-wise terms gives 84.97 Dice.

Removing the SDM loss (SimCVD w/o Lsdm) gives 88.85 Dice and 80.03 Jaccard, and the authors say this drop is not significant.

Using adaptive max pooling (SimCVD w/ Adaptive Max Pooling) gives 88.32 Dice and 79.26 Jaccard, below the full model. The authors hypothesize that this variant loses information during training.

For the alternative methods in the comparison table, the authors report paired t-test p-values close to or below 0.05 on per-case Dice scores.

Dropout rate and augmentation alternatives

Across dropout rates, LA Dice rises from 87.69 at p = 0.0 to 89.03 at p = 0.1, then falls to 88.10 at p = 0.2 and 86.67 at p = 0.5. Rates of 0.01 to 0.05 give Dice values between 87.98 and 88.01.

Each explicit augmentation is added on top of the dropout masks with p = 0.1. Local shuffle pixel gives 88.15 Dice, non-linear intensity transformation 88.02, in-painting 88.37 and out-painting 88.24, all below the dropout-only 89.03.

The authors suggest that dropout acts as a minimal form of augmentation, where the positive pair differs only in its dropout masks. They attribute the lower scores of added augmentations to extra noise during training, which can lead to representation collapse.

Pooling size is not monotonic: 16×16 gives 87.04 Dice, 128×128 gives 89.03 and 256×256 gives 87.99. The implementation uses 128×128 for the adaptive average pooling.

Limitations

Experiments cover two datasets, the LA MR dataset and the NIH pancreas CT dataset. Multi-class segmentation was not tested, and the authors plan it for future work.

The reported labeled ratios are 20% and 10% for LA and 20% for the pancreas dataset, and other ratios are not reported.

The ablations run only on LA at the 10% ratio, so component effects on the pancreas dataset are not shown.

The compared numbers are published results rather than a controlled re-run, and each setting is a single value without confidence intervals.

The authors name synthesis, enhancement and registration as possible downstream uses, and the paper tests none of them.

Paper info

Authors
Chenyu You, Yuan Zhou, Ruihan Zhao, Lawrence Staib, James S. Duncan
Venue
arXiv · Preprint
First published
2021-8-13
Added
2026-11-6
Updated
2022-3-21
Version
v4
arXiv
2108.06227
Category
cs.CV · cs.AI · cs.LG
Original paper terms
CC BY 4.0
What we show
Paper info, commentary and permitted figures from the original paper

AI commentary is a separate explanation from the original paper and may contain errors. The original paper and figures follow each source's terms of use and any rights noted separately.

Abstract

Automated segmentation in medical image analysis is a challenging task that requires a large amount of manually labeled data. However, most existing learning-based approaches usually suffer from limited manually annotated medical data, which poses a major practical problem for accurate and robust medical image segmentation. In addition, most existing semi-supervised approaches are usually not robust compared with the supervised counterparts, and also lack explicit modeling of geometric structure and semantic information, both of which limit the segmentation accuracy. In this work, we present SimCVD, a simple contrastive distillation framework that significantly advances state-of-the-art voxel-wise representation learning. We first describe an unsupervised training strategy, which takes two views of an input volume and predicts their signed distance maps of object boundaries in a contrastive objective, with only two independent dropout as mask. This simple approach works surprisingly well, performing on the same level as previous fully supervised methods with much less labeled data. We hypothesize that dropout can be viewed as a minimal form of data augmentation and makes the network robust to representation collapse. Then, we propose to perform structural distillation by distilling pair-wise similarities. We evaluate SimCVD on two popular datasets: the Left Atrial Segmentation Challenge (LA) and the NIH pancreas CT dataset. The results on the LA dataset demonstrate that, in two types of labeled ratios (i.e., 20% and 10%), SimCVD achieves an average Dice score of 90.85% and 89.03% respectively, a 0.91% and 2.22% improvement compared to previous best results. Our method can be trained in an end-to-end fashion, showing the promise of utilizing SimCVD as a general framework for downstream tasks, such as medical image synthesis, enhancement, and registration.

Quote from the paper

Chenyu You, Yuan Zhou, Ruihan Zhao, Lawrence Staib, James S. Duncan (2021). SimCVD: Simple Contrastive Voxel-Wise Representation Distillation for Semi-Supervised Medical Image Segmentation. arXiv:2108.06227v4. https://arxiv.org/abs/2108.06227v4

BibTeX
@misc{you2021simcvd,
  title = {{SimCVD: Simple Contrastive Voxel-Wise Representation Distillation for Semi-Supervised Medical Image Segmentation}},
  author = {Chenyu You and Yuan Zhou and Ruihan Zhao and Lawrence Staib and James S. Duncan},
  year = {2021},
  eprint = {2108.06227},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2108.06227v4}
}

See related papersBrowse other papers

Paper preview
Account security

Connect Google account

If you connect a Google account, you can sign in with it too.

Refivu

Delete account

Refivu
Refivu

Sign up