Paper commentary
Deep Convolutional Neural Networks for Computer-Aided Detection: CNN Architectures, Dataset Characteristics and Transfer Learning
Transfer learning and deeper CNNs improve CT lesion detection
- Problem Medical imaging has no ImageNet-sized labeled dataset, so it was unclear which CNN design suits small sets. It was also unclear whether ImageNet features carry over to CT scans.
- Method The authors compare three CNN architectures trained from scratch or fine-tuned from ImageNet weights. They test lymph node detection and lung disease classification on CT slices.
- Results GoogLeNet-RI-L reached an AUC of 0.95 and a TPR/3FP of 0.85 for mediastinal lymph node detection. For lung disease, GoogLeNet-TL reached 0.57 slice-level accuracy under five-fold cross-validation.
Why labeled medical data limits CNN training
ImageNet made large CNNs practical for natural images by providing more than 1.2 million labeled images across 1000 categories. Medical imaging has no equivalent collection, because images are hard to acquire and expert annotation is costly. That leaves open which network design suits CADe when labeled data are scarce, and whether features learned from natural photographs carry over to CT.
The study takes three factors in turn: the CNN architecture, the scale of the dataset together with the spatial context each sample carries, and transfer learning from ImageNet. Two CADe tasks serve as testbeds: lymph node detection across the thorax and abdomen, and classification of interstitial lung disease. Earlier work used three broad routes: training from scratch, feeding fixed ImageNet CNN features into separate classifiers, and unsupervised pre-training followed by fine-tuning.
Fine-tuning an ImageNet model on medical images had received little attention before this work.
Lymph node and ILD datasets
The lymph node data are a public set from prior work, with 388 labeled mediastinal nodes in 90 patient CT scans and 595 labeled abdominal nodes in 86 patient CT scans. Candidates follow the earlier sampling protocol with fields of view from 30mm to 45mm, but the study widens sampling to fields of view from 35mm to 128mm in a soft-tissue window of [-100, 200HU].
Each sample is rescaled to 64×64 pixels by B-spline interpolation, and negative candidates are re-selected so that their count stays close to the number of positives.
The ILD dataset contains 905 axial CT slices from 120 patients, each tagged with one or more of six lung tissue types: NM, EM, GG, FB, MN and CD. The annotations are partial, since many diseased regions in the slices have not been labeled. Each slice is sampled 12 times with random translations and rotations, and up to 100 patches of 64×64 pixels are taken from each ROI.
The data are split into five folds with disjoint patient sets, so a patient never appears in both training and test folds.
Turning CT into three-channel inputs
Each lymph node candidate is shown as axial, coronal and sagittal views, and these three views fill the three RGB channels. Lymph nodes have no fixed anatomical orientation, so the views are resampled at random in scale, displacement and orientation. The channels are not assumed to be spatially correlated pixel by pixel; the first convolution layers learn how to combine them.
The windows are defined directly in Hounsfield units, so they do not depend on a lung mask. The authors report no significant difference between using a rough lung segmentation and not using one, and they argue that highly accurate segmentation is unnecessary.
Architectures at three scales
It has about 0.15 million free parameters.
Because AlexNet expects 256×256×3 inputs, the filter size, stride and pooling were reduced for 64×64×3 inputs.
GoogLeNet has two convolution layers and nine Inception layers, where each Inception layer combines six convolution layers and one pooling layer. For the 64×64 variant, the first-layer filters fall from 64 to 32, the padding from 3 to 2, the kernel from 7 to 5, and the stride from 2 to 1, with the following pooling stride also reduced to 1.
The reduced width is meant to limit overfitting on the smaller medical datasets.
For the ILD experiments, Overfeat is added as a variant of AlexNet with more filters in its conv4 and conv5 layers and denser operation. VGGNet is used in its 16-layer form, with 3×3 convolution filters throughout.
Scratch training, fine-tuning and fixed features
Models trained from scratch start from random Gaussian initialization, use mini-batches of 50 images and run for 30 epochs, with momentum 0.9, weight decay 0.0005 and a base learning rate of 0.01 cut by a factor of 10 every 10 epochs. The ILD experiments use a different schedule, with up to 90 epochs and a learning rate cut every 30 epochs.
In the fine-tuned models, all layers except the last are updated at a learning rate ten times smaller than the default, while the last fully connected layer is randomly initialized and trained at 0.01. These fine-tuned models are named AlexNet-TL and GoogLeNet-TL, and their random-initialization counterparts are named AlexNet-RI and GoogLeNet-RI.
AlexNet-ImNet is a different route: the convolutional and fully connected layers stay fixed, and only a final classifier is trained on the new task. Prior work used such fixed features with support vector machines or random forests, whereas here a classifier is trained directly on the features, to test whether end-to-end fine-tuning is needed.
The authors hypothesize that CNNs trained on ImageNet can be transferred to medical image recognition tasks despite the gap between natural and medical images.
Lymph node detection results
Detection is scored by the AUC of the FROC curve and by TPR/3FP, computed with three-fold cross-validation over patient-disjoint folds, with random views averaged by probability. The abstract gives 85% sensitivity at 3 false positives per patient for mediastinal detection, while the introduction gives 86%, both against 78% for stacked shallow learning and 70% for the earlier CNN.
On the mediastinal set, GoogLeNet-RI-L reached an AUC of 0.95 and a TPR/3FP of 0.85, while the earlier CNN in [22] reached 0.92 and 0.70. AlexNet-ImNet, with only its classifier trained, reached an AUC of 0.89 on the same set, below the 0.94 of AlexNet-TL-H.
For the high-resolution GoogLeNet, transfer learning raised TPR/3FP from 0.61 with random initialization to 0.81 on the mediastinal set, and from 0.48 to 0.70 on the abdominal set. For AlexNet-TL-H the gains over AlexNet-RI-H are smaller, with TPR/3FP of 0.81 against 0.79 mediastinal and 0.69 against 0.67 abdominal.
On the abdominal set, the earlier CNN reached a TPR/3FP of 0.83, above the best proposed single models at 0.70. A simple average of five CNNs matches or slightly exceeds the best single model on each set, according to the authors.
The authors attribute the mediastinal gain partly to the wider fields of view, which add spatial context, and note that mediastinal nodes are easier to tell apart because their surroundings are more distinctive.
ILD classification under five-fold cross-validation
At patch level, all five deep models score between 0.74 and 0.76 accuracy, and their average reaches 0.79. Patch-CV5 F-scores range from 0.64 for NM and CD to 0.82 for MN, with EM at 0.81.
Slice-level accuracy is much lower: GoogLeNet-TL reached 0.57 and GoogLeNet-RI reached 0.41, while AlexNet-TL reached 0.46 and AlexNet-RI reached 0.44. Transfer learning helps at slice level for both architectures, and the authors link the GoogLeNet gain to reduced overfitting on the small CADe datasets.
The slice task is hard because the model must learn from very few labeled slices, only 905 in total, and predict labels for unseen patients. The authors note that F-scores from the hard-split study in [40] are not comparable to their own, and that F-scores change noticeably between folds.
The confusion matrix for patch-level GoogLeNet-TL shows the highest diagonal entries for EM at 0.91 and FB at 0.83, and the lowest for GG at 0.70 and CD at 0.68.
How the validation protocol and sampling change the numbers
Under leave-one-patient-out validation, GoogLeNet-TL reached 0.902 slice-level accuracy, against 0.57 under five-fold cross-validation. The authors argue that leave-one-patient-out is much easier and not directly comparable to five-fold cross-validation. Under the same LOO protocol, patch-level GoogLeNet-TL reached 0.911, and slice-level AlexNet-TL reached 0.867 and Overfeat-TL 0.877.
In the sampling comparison, GoogLeNet-TL trained with equal priors reached 0.902 slice-level accuracy and biased priors reached 0.872. Patch-level accuracy changed little, from 0.953 with equal priors to 0.952 with biased priors.
The equal-prior slice value matches the LOO figure for GoogLeNet-TL, but the text does not say the two share a protocol, so they should not be read as the same setting.
Training cost differs widely: CifarNet took 7m16s and 2.25 GB, AlexNet 1h2m and 3.45 GB, GoogLeNet 2h49m and 5.37 GB, and VGG-16 20h24m and 9.26 GB, on ILD patch training up to 90 epochs. The batch size was 128, reduced to 64 for GoogLeNet and 32 for VGG-16 to fit the 12GB K40 GPU.
What fine-tuning changes inside the network
On LN data, first-layer filters of AlexNet-TL at 256×256 show higher-order contrast and edge patterns that the random-initialization models lack. At 256×256 the random-initialization models have over-smooth low-level filters, while at 64×64 some contrast filters appear.
When AlexNet is trained from random initialization on ILD data, the training loss falls toward zero while the validation loss rises and validation accuracy hardly improves before plateauing. The authors interpret this as overfitting on the small ILD dataset. Fine-tuned AlexNet starts from parameters near a good solution, and its validation loss stays lower and ends with higher accuracy.
Pool-5 activation maps and their reconstructions show that the fine-tuned AlexNet-TL localizes ILD regions better than AlexNet-ImNet. The reconstructions are obtained by deconvolution from chosen pooling units, and the most active units account for the top 5% of responses. The authors also observe that a classification score is driven by a sparse set of high activations, not by a single strong one.
Limits of the evidence
The authors suggest that the ILD set, with only 120 patients, may not adequately represent the CT patterns of ILD. The ILD labels are partial, and a pixel-wise relabeling by segmentation label propagation is only proposed in [47], not used here.
Slice-level learning is restricted to 905 labeled slices, and the best slice-level accuracy under five-fold cross-validation is 0.57.
The lymph node sets contain 388 and 595 labeled nodes from 90 and 86 scans, and the authors state that more abdominal scans from distinct patient populations are needed. CifarNet is described as under-trained on the enlarged LN data, because of its limited input resolution and parameter count. The merged ILD and LTRC dataset is proposed as a route forward, but no results for it appear in the reported tables.
Paper info
- Authors
- Hoo-Chang Shin, Holger R. Roth, Mingchen Gao, Le Lu, Ziyue Xu, Isabella Nogues, Jianhua Yao, Daniel Mollura, Ronald M. Summers
- Venue
- arXiv · Preprint
- First published
- 2016-2-10
- Added
- 2026-11-11
- Updated
- 2016-2-10
- Version
- v1
- arXiv
- 1602.03409
- Category
- cs.CV
- Original paper terms
- arXiv non-exclusive 1.0
- What we show
- Paper info and commentary
AI commentary is a separate explanation from the original paper and may contain errors. The original paper and figures follow each source's terms of use and any rights noted separately.
Quote from the paper
Hoo-Chang Shin, Holger R. Roth, Mingchen Gao, Le Lu, Ziyue Xu, Isabella Nogues, Jianhua Yao, Daniel Mollura, Ronald M. Summers (2016). Deep Convolutional Neural Networks for Computer-Aided Detection: CNN Architectures, Dataset Characteristics and Transfer Learning. arXiv:1602.03409v1. https://arxiv.org/abs/1602.03409v1
BibTeX
@misc{shin2016deep,
title = {{Deep Convolutional Neural Networks for Computer-Aided Detection: CNN Architectures, Dataset Characteristics and Transfer Learning}},
author = {Hoo-Chang Shin and Holger R. Roth and Mingchen Gao and Le Lu and Ziyue Xu and Isabella Nogues and Jianhua Yao and Daniel Mollura and Ronald M. Summers},
year = {2016},
eprint = {1602.03409},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/1602.03409v1}
}