Profile

Settings

Loading…

← Papers

Help

FAQ

Which features require signing in?

You can read the commentary, paper info, Model Structure and related papers of public papers without signing in. Sign in to manage your account or contact us about your inquiries.

Can I upload a PDF file?

Upload papers with an arXiv or DOI link; the commentary is public to everyone. Papers whose source and terms of use can't be verified, so the commentary can't be made public, can't be uploaded. Uploading PDF files and keeping papers private are for subscribers only, and a paper uploaded as a file is saved as private only. Searching for official info by title runs only when you press the button.

Are the figures and AI commentary accurate?

Figures come only from the original paper, and only those whose terms of use are verified are shown. The commentary is written by AI and may be wrong. Check important claims, numbers and figure context against the evidence in the original paper.

I want to report a copyright issue.

Terms of use and the source of the original paper are on the Paper info tab. If there's a problem, choose "Paper content, figures and copyright" under Contact us and send the paper link, the part in question, and evidence that you hold the rights. Receiving your report doesn't confirm any rights or remove anything right away. You can see the result of the review under My inquiries.

I forgot my password.

If you signed up with email, use Forgot password in the sign-in window to reset it with your verified email. If you signed up with Google, Naver or Kakao, change your password with that service.

What should I include in an inquiry?

Tell us which screen you were on and what you were doing when the problem happened, along with the paper link. Don't include personal information such as passwords, API keys, verification codes or phone numbers. Inquiries and replies are stored in Refivu and you can see them under My inquiries.

How do I delete my account?

In Settings, under My account, press Delete account. Review what will be deleted and complete identity verification to delete your account. For other requests, choose "Account" under Contact us.

Paper commentary

iMED: A Multi-Endoscope Dataset for Surgical 3D Perception

Researchers release a multi-endoscope dataset that tests surgical 3D models on independent viewpoints

  • Problem Surgical 3D benchmarks score models on nearby frames from one endoscope path. Such scores can't show whether a model generalizes to independent viewpoints.
  • Method iMED records the same scene with two stereo endoscopes at once and tests each model on the other endoscope's views.
  • Results Across 23 methods, photometric-only models degrade substantially on the held-out endoscope, while geometrically regularized ones hold up better.

Figure 1: Data platform with two stereo endoscopes (top-left), common camera trajec-
tories (top-right), and pipeline outputs including session/anatomy/instrum…

Fig. 1 :Data platform with two stereo endoscopes (top-left), common camera trajec- tories (top-right), and pipeline outputs including session/anatomy/instrument/motion labels, camera intrinsics, ArUco pose estimates, inferred tool masks , stereo depth (code provided), and derived 3D geometry. See Tab. 2 for provenance.

Original paper · CC BY 4.0 · Sierra Bonilla, Fengyi Jiang, Chinedu Nwoye, Jingpei Lu, Kailey Reardon, Humphrey W. Chow, Francisco Vasconcelos, Sophia Bano, Adam Schmidt, Omid Mohareri · iMED: A Multi-Endoscope Dataset for Surgical 3D Perception · Original paper figure · Extracted the figure area from page 2 of the original PDF.

Why same-trajectory scores can mislead

Novel view synthesis methods are usually scored by rendering held-out camera poses and comparing the output with the real image using PSNR and SSIM. In surgery, those held-out poses usually sit on the same forward-facing path as the training frames, only a few frames away in time. Such test views differ only slightly from the training views, so a high score can come from blending nearby views.

So the authors ask a harder question: does a model still work when the camera moves far enough that interpolation runs out?

Human capture benchmarks already answer that question by training on some cameras and testing on others. Surgery has no such setup, since a surgeon can't place dozens of cameras inside the body and an endoscope follows only one narrow path. Earlier surgical datasets offer many sequences, but each comes from a single endoscope along a single path.

Without a second, independent viewpoint, a score can't tell geometric generalization apart from photometric interpolation.

The train-on-one-endoscope, test-on-another protocol tests generalization to physically independent viewpoints rather than to nearby frames along one trajectory. iMED supplies that second viewpoint with two physically independent stereo endoscopes that record 340 sequences at the same time.

Two endoscopes as independent viewpoints

The key idea is to record the same scene with two stereo endoscopes at the same time, and treat one endoscope's views as held-out for a model trained on the other. Each endoscope contributes its own stereo pair, so one capture yields four camera streams per timepoint. Endoscope 1 is the stationary endoscope on an articulated passive arm, and it stays fixed during data collection.

Endoscope 2 is the mobile endoscope on the robotic patient cart, and only its integrated light source was switched on during acquisition. Because the two endoscopes see different illumination, the authors normalize their photometric appearance using sequence-level statistics.

The release contains 340 sequences totaling ≈170K synchronized timepoints, each with four views. The authors sampled 10 ex vivo organ specimens, 3 human cadaver subjects and 1 live porcine subject. Each 10-15 second sequence includes static scenes, respiratory motion and tool-tissue interactions with 20 common robotic instruments.

The two endoscopes sit 2.6±1.2 cm apart with an 18.7°±10.0° orientation difference. That gap is substantially larger than the 4mm stereo baseline inside each endoscope. Frames from the two endoscopes are hardware-synchronized, with a mean timing difference of 3.36 ms (SD = 3.90 ms). That timing difference is much less than the ≈17ms frame duration, so paired frames show the same moment.

Building reference poses from cube markers

The two endoscopes can't be measured against each other directly, so the authors build an external calibration system around custom cubes that both cameras can see. Each cube is an 8mm wooden block carrying 5.7mm ArUco markers from the ARUCO_MIP_36h12 dictionary. Because the cubes can be manipulated by robotic instruments, the team could place them throughout the working volume during acquisition.

Marker corners seen by both endoscopes then give the relative transform between them.

A Perspective-n-Point solver turns each marker detection into a 6-DOF pose, using the known marker geometry and the camera intrinsics. The pipeline aggregates these observations over a sliding window and computes camera-to-camera transforms for commonly visible markers. RANSAC selects inlier observations based on angular and translational consistency thresholds, and Levenberg-Marquardt then refines the best hypothesis by minimizing bidirectional reprojection error across all inlier marker corners.

They average these two estimates with quaternion interpolation to get the final trajectory. Frame-to-frame velocity analysis then rejects poses that jump by more than 0.7 cm per frame or 3.0 degrees per frame.

The surviving trajectory is smoothed with a Savitzky-Golay filter, using a window of 15 frames and polynomial order 1 on translation. Rejected poses are filled by linear interpolation for translation and SLERP for rotation between smoothed neighbors. The ablations show up to 90% lower reprojection error and sub-2mm physical error at 5cm working distance.

For ex vivo sessions, Table 3 reports 38.33 pixels of reprojection error and 1.88 mm of physical error at 5cm. In vivo postmortem sessions reach 17.00 pixels and 0.83 mm, while in vivo live sessions reach 11.87 pixels and 0.58 mm. The authors release the trajectories, raw calibration sequences, and recomputation code, so users can rerun the pipeline.

Novel view synthesis under the held-out setting

Depth supervision changes the picture on rigid NVS, and the effect depends on the representation. 3DGS went the other way: adding FoundationStereo raised PSNR from 14.82 to 15.33 and SSIM from 0.59 to 0.63. So depth supervision doesn't help every representation, and the effect depends on the model.

Vanilla NeRF's SSIM rose monotonically as the rendering approached the test pose, which is the expected case. The depth-supervised NeRF didn't follow that trend, even though its geometry converged. Citing earlier work, the authors suggest NeRF can model semi-transparent volumes to imitate reflections, and depth supervision may make that worse.

The resulting artifacts worsen as views diverge from the training distribution.

Figure 5: Left:Rendered test views show ghost-like artifacts in depth-supervised variants.
Right:SSIM computed against the test held-out image during camera in…

Fig. 5 :Left:Rendered test views show ghost-like artifacts in depth-supervised variants. Right:SSIM computed against the test held-out image during camera interpolation from a training (0%) to test (100%) viewpoint. NeRF (purple) improves monotoni- cally, while depth-supervised variants degrade despite geometric convergence, suggest- ing transparent density surfaces rather than opaque geometry.

Original paper · CC BY 4.0

The deformable methods were compared offline (D-3DGS, 4DGS, Endo-4DGS) and online (Hayoz, DynOmo). Methods that rely only on photometric loss, like D-3DGS, reach low performance because they allow unconstrained per-Gaussian warping. That warping produces reconstructions that disagree across independent viewpoints. The 4DGS variants add temporal regularization through total variation constraints but lack explicit spatial coherence, giving marginal gains.

Endo-4DGS gets better quality from depth supervision, surface normal consistency, and confidence weighting. It applies dense 3D constraints to every Gaussian, including local rigidity, isometry, and feature-similarity neighbor selection. The authors credit these constraints and its foundation-model features for keeping quality across the 2.6cm and 18.7° viewpoint shift.

That quality comes at a price in training time. DynOmo took 16 seconds per frame in training, against 1 second per frame for Endo-4DGS. They frame the cost as coming from neighborhood computation, multi-constraint optimization, and dense feature matching.

Pose matching and monocular depth on surgical pairs

The set covers handcrafted SIFT, learned sparse matchers such as SuperPoint and DISK with LightGlue, and dense matchers built on foundation models like RoMa and MASt3R. Rotation error and inlier rate were computed across all 30 sequences to test generalization over diverse surgical scenes, anatomies, and imaging conditions. Dense foundation-model matchers were most accurate: RoMa produced 3905 inliers at a 78.1% inlier rate and 1.79° rotation error.

Figure 7 shows inlier and outlier matches for these methods, with the average rotational error printed beside each method name.

Figure 7: Qualitative comparison of image matching methods showing correspondence
quality. Green lines indicate inlier matches; red lines indicate outliers. Th…

Fig. 7 :Qualitative comparison of image matching methods showing correspondence quality. Green lines indicate inlier matches; red lines indicate outliers. The angle next to the method name is the average rotational error.

Original paper · CC BY 4.0

Accuracy alone doesn't settle which matcher suits tracking, because frame-to-frame stability matters too. For the 23 sequences with tool-tissue deformation and static cameras, the authors measured temporal consistency as the standard deviation of rotation errors. GIM+LightGlue showed a 0.41° temporal drift, compared with 1.38 to 2.00° for dense methods, at a slightly lower absolute accuracy.

SIFT's 4.04° rotation error with 14.45 standard deviation shows that learned methods gave better accuracy with lower variance.

Monocular depth models were scored against depth from FoundationStereo, with median scaling giving each sequence a single optimal scale. The authors benchmarked two surgical models, Endo3R and EndoDAC, against two metric-scale models, UniDepth-V2 and MoGe-V2, on 30 test sequences. UniDepth-V2 reached an Abs Rel of 0.081 with median scaling, the lowest of the four models, while Endo3R reached 0.187.

EndoDAC, fine-tuned on surgical data, reached 0.119, so the general-purpose metric models beat the surgical-domain methods.

Without median scaling, UniDepth-V2 and MoGe-V2 had δ1 accuracy of 0.000, with Abs Rel errors of 11.573 and 14.556. They didn't test scale calibration methods themselves, so that step remains a recommendation rather than a measured result.

Limitations of the benchmark

Ex vivo sequences use hand-guided endoscope motion, so their trajectories are less smooth than robotic ones. Hand-guided motion means the ex vivo trajectories don't match the smoothness of robotic manipulation in RAMIS. Viewpoint diversity is lower than in classic multi-view datasets, because trocar placement, visibility and safe camera motion limit the camera.

Surgical acquisition is constrained by these three factors, so the dataset can't reach the viewpoint spread of surgical-free benchmarks. More subjects and anatomies are left as future work.

Depth metrics are measured against stereo-derived reference depth, not against a measured ground truth. The reference depth comes from FoundationStereo, so the depth benchmark inherits the errors of that stereo prior. Several methods run far slower than the rest, which limits real-time use. DynOmo needs 16 seconds per frame in training, against 1 second per frame for Endo-4DGS, a 16× slowdown.

MicKey did not produce valid correspondences across all surgical sequences. This failure leaves a gap for metric pose estimators that stay robust in deformable scenes. The conclusion that multi-domain training will help is a hypothesis, and the benchmark doesn't test it directly.

Paper info

Authors
Sierra Bonilla, Fengyi Jiang, Chinedu Nwoye, Jingpei Lu, Kailey Reardon, Humphrey W. Chow, Francisco Vasconcelos, Sophia Bano, Adam Schmidt, Omid Mohareri
Venue
arXiv · Preprint
First published
2026-11-3
Added
2026-11-5
Updated
2026-11-3
Version
v1
arXiv
2611.04755
DOI
10.1007/978-3-032-37393-9_19
Category
cs.CV · cs.RO
Original paper terms
CC BY 4.0
What we show
Paper info, commentary and permitted figures from the original paper

AI commentary is a separate explanation from the original paper and may contain errors. The original paper and figures follow each source's terms of use and any rights noted separately.

Abstract

We introduce iMED, the first synchronized multi-endoscope dataset for robot-assisted minimally invasive surgery (RAMIS), designed to address a fundamental limitation in surgical vision benchmarking: the absence of independent held-out viewpoints. Existing surgical datasets capture single-trajectory sequences from a single endoscope, making it impossible to distinguish geometric generalization from photometric interpolation along a narrow forward-facing path. iMED provides 340 sequences ~170K synchronized timepoints with 4 views per timepoint) recorded simultaneously from two independent stereo endoscopes across ex vivo, postmortem, and live surgical settings, spanning 14 specimens with diverse anatomical regions and motion regimes. The dataset includes calibrated camera intrinsics, ArUco-based frame-wise pose estimates with uncertainty quantification, instrument segmentation masks, and rich clinical metadata. Using a train-on-one-endoscope, test-on-another evaluation protocol, we benchmark 23 state-of-the-art methods across rigid and deformable novel view synthesis, pose estimation, feature matching, and monocular depth estimation. Our experiments show that methods relying primarily on photometric supervision degrade substantially under this held-out-endoscope setting, while methods with explicit geometric regularization are more robust across views in our benchmark. Notably, large-scale foundation models transfer surprisingly well to surgical imagery, often outperforming domain-specific models, suggesting pitfalls in current fine-tuning protocols. iMED establishes a new evaluation protocol for geometric generalization in surgical vision.

Quote from the paper

Sierra Bonilla, Fengyi Jiang, Chinedu Nwoye, Jingpei Lu, Kailey Reardon, Humphrey W. Chow, Francisco Vasconcelos, Sophia Bano, Adam Schmidt, Omid Mohareri (2026). iMED: A Multi-Endoscope Dataset for Surgical 3D Perception. arXiv:2611.04755v1. https://doi.org/10.1007/978-3-032-37393-9_19

BibTeX
@article{bonilla2026imed,
  title = {{iMED: A Multi-Endoscope Dataset for Surgical 3D Perception}},
  author = {Sierra Bonilla and Fengyi Jiang and Chinedu Nwoye and Jingpei Lu and Kailey Reardon and Humphrey W. Chow and Francisco Vasconcelos and Sophia Bano and Adam Schmidt and Omid Mohareri},
  year = {2026},
  eprint = {2611.04755},
  archivePrefix = {arXiv},
  doi = {10.1007/978-3-032-37393-9_19},
  url = {https://arxiv.org/abs/2611.04755v1}
}

See related papersBrowse other papers

Paper preview
Account security

Connect Google account

If you connect a Google account, you can sign in with it too.

Refivu

Delete account

Refivu
Refivu

Sign up