Profile

Settings

Loading…

← Papers

Help

FAQ

Which features require signing in?

You can read the commentary, paper info, Model Structure and related papers of public papers without signing in. Sign in to manage your account or contact us about your inquiries.

Can I upload a PDF file?

Upload papers with an arXiv or DOI link; the commentary is public to everyone. Papers whose source and terms of use can't be verified, so the commentary can't be made public, can't be uploaded. Uploading PDF files and keeping papers private are for subscribers only, and a paper uploaded as a file is saved as private only. Searching for official info by title runs only when you press the button.

Are the figures and AI commentary accurate?

Figures come only from the original paper, and only those whose terms of use are verified are shown. The commentary is written by AI and may be wrong. Check important claims, numbers and figure context against the evidence in the original paper.

I want to report a copyright issue.

Terms of use and the source of the original paper are on the Paper info tab. If there's a problem, choose "Paper content, figures and copyright" under Contact us and send the paper link, the part in question, and evidence that you hold the rights. Receiving your report doesn't confirm any rights or remove anything right away. You can see the result of the review under My inquiries.

I forgot my password.

If you signed up with email, use Forgot password in the sign-in window to reset it with your verified email. If you signed up with Google, Naver or Kakao, change your password with that service.

What should I include in an inquiry?

Tell us which screen you were on and what you were doing when the problem happened, along with the paper link. Don't include personal information such as passwords, API keys, verification codes or phone numbers. Inquiries and replies are stored in Refivu and you can see them under My inquiries.

How do I delete my account?

In Settings, under My account, press Delete account. Review what will be deleted and complete identity verification to delete your account. For other requests, choose "Account" under Contact us.

Paper commentary

Medical Image Segmentation: Foundation Model Adaptation versus Task-Specific Training

  • Problem Foundation models pretrained on natural images are being adapted for medical segmentation, but comparisons with task-specific networks usually stay within the training distribution, against one baseline, at one setting, so their cross-site and capacity conclusions remain unclear.
  • Method Adapts the DINOv2-Small encoder with a frozen configuration, BitFit, LoRA at ranks 4 to 32 and full fine-tuning, each with a linear decoder, and compares it with a plain U-Net and a ResU-Net trained from scratch under the nnU-Net recipe across colonoscopy, breast ultrasound and dermoscopy, with in-domain and out-of-distribution tests kept apart.
  • Results In domain at the full training set, the plain U-Net scored 0.8803 against 0.8780 for DINOv2 with LoRA at rank 32, a gap below the 0.013 floor. LoRA at 2.7 per cent of the parameters matched or beat full fine-tuning in polyp DSC.

Figure 3: Model architectures. (a) The five-level encoder–decoder topology shared by both task-specific comparators.
(b) One block in each variant. The two dif…

Figure 3 : Model architectures. (a) The five-level encoder–decoder topology shared by both task-specific comparators. (b) One block in each variant. The two differ in the residual addition and its projection shortcut, applied in both encoder and decoder, while widths, normalisation, activation, downsampling and training recipe are identical. (c) The adapted model: a DINOv2-Small encoder producing 384-dimensional patch embeddings, reduced to a one-channel logit map by a single1×1convolution of 385 parameters and upsampled to the input resolution. The magnified block shows where each adaptation strategy intervenes. Blue marks parameters held frozen and red marks parameters updated.

Original paper · CC BY 4.0 · Emre Kutlusan, Yongmin Li · Medical Image Segmentation: Foundation Model Adaptation versus Task-Specific Training · Original paper figure · Extracted the figure area from page 9 of the original PDF.

Why cross-site evaluation changes the question

A segmentation model trained at one hospital is later used at others, where scanners, protocols and patient populations differ. The study treats this distribution shift as the main barrier to clinical use, and in-distribution accuracy does not reveal it.

Two axes and one shared backbone

The architecture axis compares an adapted DINOv2-Small encoder with a plain U-Net and a ResU-Net trained from random initialisation. The adaptation axis compares only DINOv2 configurations with one another, from a frozen encoder up to full fine-tuning.

The encoder is the smallest released DINOv2 variant, with 22.1 million parameters. Its 384-dimensional patch embeddings pass through one 1×1 convolution to a one-channel logit map, which is bilinearly upsampled to the input resolution, giving 385 trainable decoder parameters.

A small linear decoder keeps the adaptation axis focused on how much the encoder must change, instead of how much a heavier decoder could absorb. The frozen configuration therefore serves as a minimal baseline rather than a competitive model.

The two axes meet at a single point rather than forming a factorial design. Only one DINOv2 configuration enters the architecture comparison, selected on in-domain validation, so claims about the adaptation axis rest on a single backbone.

What each adaptation strategy trains

BitFit freezes the weight matrices and trains only bias terms, which here means all encoder bias terms together with the decoder. Having no rank parameter and acting on different sites, it serves as a control for whether the capacity requirement belongs to low-rank factorisation.

The capacity axis runs from 385 trainable parameters for the frozen configuration to 22,056,961 for full fine-tuning, which the study reports as all weights of the encoder plus the decoder.

BitFit alone received a per-domain learning-rate search over 1e-2, 3e-3, 1e-3 and 3e-4 on in-domain validation, while LoRA and full fine-tuning were not searched. This asymmetry favours BitFit, and the authors flag it wherever it bears on a result.

Task-specific baselines and their configuration

The plain U-Net is the conventional reference, and the residual U-Net adds residual blocks to both encoder and decoder. Both are trained under the nnU-Net recipe, each tuned independently, so a shortfall in one design cannot be blamed on a single architectural choice.

Domains, splits and the leakage checks

Each domain has one training source and held-out sets from other institutions. Polyp trains on Kvasir-SEG and CVC-ClinicDB with 1,305 training and 145 validation images, breast on BUSI with 479 and 54, and skin on ISIC 2018 with 2,075 and 519.

In-domain parity and the out-of-distribution deficit

The skin deficits are small in magnitude but not reversed in direction. The authors note that PH2, the only fully independent skin source, shows the smallest plain U-Net deficit of the three skin sets, which does not support the explanation that the milder shift of the other two sets accounts for the result.

Failure modes on small lesions and boundaries

At its selected configuration the adapted model predicted no lesion on 13 polyp images, whereas the plain U-Net did so on none. The residual variant also predicted an empty mask on four polyp images.

Why a file-level check was not enough

A pixel-level comparison was needed to find the overlap between CVC-T and CVC-ColonDB, because all 60 CVC-T images are pixel-identical to CVC-ColonDB images, yet no file is byte-identical and an md5 check passes.

The authors note that EndoScene defines its CVC-T images as drawn from CVC-ColonDB, which is consistent with the overlap. The study therefore treats the two sets as non-independent when it counts out-of-distribution evidence.

Paper info

Authors
Emre Kutlusan, Yongmin Li
Venue
arXiv · Preprint
First published
2026-11-10
Added
2026-11-12
Updated
2026-11-10
Version
v1
arXiv
2611.14519
Category
cs.CV · cs.AI
Original paper terms
CC BY 4.0
What we show
Paper info, commentary and permitted figures from the original paper

AI commentary is a separate explanation from the original paper and may contain errors. The original paper and figures follow each source's terms of use and any rights noted separately.

Abstract

Foundation models pretrained on large natural-image collections are increasingly adapted for medical image segmentation, in the expectation that they will replace models trained for each task. Most comparisons, however, use data from the training distribution and a single task-specific baseline whose configuration is rarely justified, and therefore provide limited evidence of performance at new clinical sites. It also remains unclear how much of a foundation model must be adapted, and what determines this. We adapted a foundation model, DINOv2, with strategies ranging from tuning only its bias terms to full fine-tuning, and compared it with U-Nets and ResU-Nets trained from scratch. Experiments covered colonoscopy, breast ultrasound and dermoscopy, with testing on held-out data from the training source and on independent datasets from other institutions. The adapted foundation model generalised better on every external dataset. Within the training distribution, the task-specific models remained competitive when training data were abundant, and delineated boundaries more precisely, while the foundation model more often missed small lesions. Only a small fraction of the foundation model required adaptation, and the capacity needed was determined by the imaging domain rather than by the adaptation method. A widely used polyp test set was also found to duplicate images from another benchmark. Foundation-model adaptation is therefore warranted where models must work across sites, with capacity selected on the target domain.

Quote from the paper

Emre Kutlusan, Yongmin Li (2026). Medical Image Segmentation: Foundation Model Adaptation versus Task-Specific Training. arXiv:2611.14519v1. https://arxiv.org/abs/2611.14519v1

BibTeX
@misc{kutlusan2026medical,
  title = {{Medical Image Segmentation: Foundation Model Adaptation versus Task-Specific Training}},
  author = {Emre Kutlusan and Yongmin Li},
  year = {2026},
  eprint = {2611.14519},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.14519v1}
}

See related papersBrowse other papers

Paper preview
Account security

Connect Google account

If you connect a Google account, you can sign in with it too.

Refivu

Delete account

Refivu
Refivu

Sign up