Paper commentary
Beyond Segmentation: Enriching ImageCAS with Coronary Ostia Landmarks, Rooted Centerline Graphs, and Open-Weight Localization Models
Enriched ImageCAS dataset adds coronary ostium landmarks and rooted centerline graphs
- Problem Ostium localizers had little public CCTA data to train and test on. The only public ostium labels cover 77 non-gated aortic scans, and ImageCAS, the largest public CCTA set, has no ostium information.
- Method The authors add left and right ostium annotations to all 1000 ImageCAS volumes. A model proposes candidates for the second batch, and an annotator corrects them instead of marking each one by hand.
- Results SwinUNETR-V2 and nnResUNet localized all ostia without failure above 5 mm, with median errors of 0.70 to 0.87 mm.
Why ostium labels are scarce
Ostium localization matters for surgical planning and vessel tracking, yet public data for it is very thin. Manual placement is time-consuming, and observers disagree about the exact point where the aorta becomes a coronary artery. Automated localizers are therefore the practical route, since the ostia are the natural seed points for segmentation and centerline tracking.
Most ostium localizers were trained and evaluated on private datasets, so their results can't be compared directly.
The only public ostium labels come from ImageTBAD, which holds 77 non-gated aortic CT angiography scans. Against gated CCTA, the same kind of localizer reached 1.14 and 0.98 mm, so this work leaves the ImageTBAD scans out. ImageCAS, the largest public CCTA set for segmentation with 1000 volumes, carries no ostium information at all.
Centerlines face a similar gap, because no public centerline graphs follow the official ImageCAS masks. Those starting points are heuristic rather than the ostia that a localizer predicts, and the 200 scans left out have no centerlines. ImageCAS provides no ostium annotations, so the authors had to create them before any centerline could be rooted at an ostium.
The authors therefore set out to supply ostium labels for all 1000 volumes and centerlines rooted at them, on the official ImageCAS masks.
The first 500 ImageCAS volumes were annotated manually by six annotators, each responsible for 250 images. Rotating groups of three annotators, reshuffled every 25 images, meant that no single annotator's bias would spread uniformly through the dataset.
Building the ostium labels
The authors treat the left and right ostia as two separately labeled landmarks in each CCTA. For the first 500 ImageCAS volumes, six annotators each handled 250 images, working in rotating groups of three. Groups were reshuffled every 25 images, so no single annotator's bias could spread uniformly through the dataset. Each image received three independent markers in 3D Slicer, and the consensus position was their arithmetic mean.
The leave-one-out error averaged 1.45 mm for the right ostium and 1.95 mm for the left ostium across the first batch.
For the other 500 volumes, a SwinUNETR-V2 trained on CAT08, ASOCA and the first batch proposed a candidate ostium for each case. One annotator, Annotator 4, checked every candidate against the CCTA volume and corrected it where necessary. The model only supplied an initialization, so this lighter process isn't methodologically equivalent to the first stage.
For that reason, the authors drew the test set only from the first batch. The reviewer refined 88 of the 500 candidates (17.6%), each by 1 mm or less. The model missed the ostium in 10 images (2.0%), which the annotator placed manually. Correction took about 5 person-hours, while the fully manual first batch took about 144 person-hours.
The effort figures come from a timed comparison in which inference was unattended and only review time counted as human effort. The consensus labels cover the first batch, so the reference positions carry an uncertainty of the same order as the model errors. Annotators were biomedical engineers rather than clinicians, and the second batch rests on one reviewer without independent verification.
Rooted centerlines from minimal paths
Rather than thinning the segmentation mask into a skeleton, the method grows each coronary tree outward from its ostium. Thinning tends to create spurious branches and loops where the mask is irregular, whereas growth from one root gives a tree by construction.
The mask is resampled to 0.5 mm voxels, and the cost of a voxel \( x \) is \( c(x) = (D(x) + 0.5)^{-p} \) with \( p = 4 \), where \( D(x) \) is its distance from the mask boundary in voxels. Because the cost falls steeply as a path moves away from the wall, minimal paths stay short and close to the vessel axis. Minimal-cost fronts from each ostium give every voxel a geodesic distance and a predecessor, and they split the mask into left and right trees, bridging gaps up to 10 mm.
Growth repeatedly takes the uncovered voxel farthest from the ostium, traces its path back to the tree, and keeps the path only if it runs at least 5 mm outside the covered region. A second pass caps the wall distance at 1.2 times the local vessel radius, which keeps the paths centred at bulky bifurcations. The tips are then trimmed by 2 mm, the branches smoothed and resampled every 0.5 mm, and each node stores position, lumen radius, type and side.

Figure 2 : Centerline extraction pipeline. (1) Inputs: the coronary segmentation mask and the annotated left and right ostia (orange dots), resampled to a 0.5 mm isotropic grid and cropped to the arteries. (2) Centered cost: the cost of Eq. (1) decreases steeply with the distance DT from the vessel wall, so that minimal paths are both short and central; each ostium is bridged to the mask. (3) Ostium fronts: a minimal-cost front propagated from each ostium gives the geodesic distanceGand the minimal path (predecessor map) of every voxel, and splits the mask between the left (L) and right (R) trees according to the ostium that reaches each voxel; mask gaps of up to 10 mm are bridged. (4) Tree growth: the uncovered voxel farthest from the ostium (star) is traced back to the tree along its minimal path, which is kept as a new branch only if it adds at least 5 mm outside the region already covered (cross: rejected path), so that the result is a tree by construction. The growth is then repeated in a second pass with the wall distance capped at 1.2 times the local vessel radius (bottom arrow), which keeps the paths on the vessel axis at bulky bifurcations. (5) Centerline graph: the tips are trimmed by 2 mm and the trees smoothed branch by branch and resampled every 0.5 mm, yielding one tree per side, rooted at its ostium (square), with endpoints (circles), bifurcations, and per-node position, lumen radius, topological type and side, stored as one graph per patient. Full details are given in Appendix A.3.
Original paper · CC BY 4.0 · Matteo Leccardi, Andrea Moglia, Marco Morandini, Michele Brembilla, Alessandro Nicosia, Andrea Penserini, Christian Brandini, Ender Konukoglu, Marco Marcon, Luca Mainardi, Pietro Cerveri · Beyond Segmentation: Enriching ImageCAS with Coronary Ostia Landmarks, Rooted Centerline Graphs, and Open-Weight Localization Models · Original paper figure · Extracted the figure area from page 6 of the original PDF.On the 40 ASOCA volumes, whose reference centerlines come from the same masks, the extraction covers a median of 99.5% of the reference length. The median per-patient mean distance is 0.22 mm, and the matched centerlines lie closer than half of the 0.5 mm grid, with no reference branch of 10 mm or more missed. The reference centerlines were also computed as minimal paths, so part of this agreement may come from the similarity of the two methods.
Heatmap localizers and their loss
The three maps cover the background, the right ostium and the left ostium, in the same spatial reference as the input. Loss, preprocessing, training strategy, postprocessing and evaluation stay common to all models, so architecture is the only variable. SwinUNETR-V2 combines a hierarchical shifted-window Transformer encoder with a U-Net-like decoder, and it uses a feature size of 24.
The ResNet50 and ResNet101 models use MONAI 3D residual encoders trained from scratch, and they end in a light heatmap head. That head applies a 3 × 3 × 3 convolution, group normalization, a ReLU and a 1×1×1 convolution, and trilinear upsampling restores the input resolution. nnResUNet is a five-stage residual encoder–decoder with feature widths of 32, 64, 128, 256 and 320.
MedNeXt-S and MedNeXt-B follow a ConvNeXt-inspired design with 3 × 3 × 3 kernels and no deep supervision.
Every model is trained with one ostium-localization loss, which follows Gajowczyk et al. and reads the coordinates the heatmaps encode. The DSNT turns a spatial probability distribution into continuous coordinates, so the network can be optimized on the coordinate error while still producing dense heatmaps. A temperature-scaled spatial softmax with T = 0.3 sharpens each channel's distribution, which limits the pull of diffuse background activations on the expected coordinate.
The DSNT then computes the expected coordinate over the normalized grid, and the Euclidean term L_E compares it with the target. A Jensen–Shannon term pulls the predicted distribution toward a Gaussian centered on the target landmark. The loss uses λ_JSD = 1.0, λ_bg = 0.8 and a Gaussian standard deviation of 2.0 voxels. A crop that lacks a given ostium is masked out for that channel, so it adds nothing to that channel's loss.
Background voxels around the ostium, such as the aortic wall and the cardiac chambers, are pushed toward zero by the binary cross-entropy term. The right and left losses are combined with weights that start at 0.5 each and adjust within [0.25, 0.75].
Before the loss, the images are resampled to 0.5 mm and clipped between -200 and 800 Hounsfield Units. The same preprocessing runs in training, validation and inference, so ImageCAS, CAT08 and ASOCA share one input domain.
Benchmark results on 58 held-out CCTAs
The benchmark test set holds 58 volumes, 50 from ImageCAS, 4 from CAT08 and 4 from ASOCA, and each model was trained on the 950 CCTAs outside it. SwinUNETR-V2 and nnResUNet produced no localization above 5 mm, with per-patient median errors between 0.70 and 0.87 mm. Neither model failed, and 98.3% and 96.6% of their cases were graded Optimal or Good on both sides.
nnResUNet processed each CCTA in 41.1 s, while SwinUNETR-V2 took 55.6 s. These times include volume loading and export, so they don't measure the network alone.

Table 5 : Euclidean distanced c (mm) of the benchmark models trained on the complete ImageCAS dataset (the 950 CCTAs not in the test set) and tested on 58 CCTAs, for the right ostium, the left ostium, and both (per-patient average of the right and left distances). The line below each row gives the percentage of cases in each accuracy bucket (for both, at patient level): O = Optimal, G = Good, A = Acceptable, F = Failed. See Section 3.8. In each distance column, the best value is in bold and the second best is underlined, comparing the rows of the same kind (overall and, separately, each dataset).
Original paper · CC BY 4.0The two ResNets were about three times less precise than the leading models, yet they rarely failed. The authors link this to the light head and trilinear upsampling, which lose fine spatial detail whatever the encoder depth. Since MedNeXt-B is not better than MedNeXt-S, the authors suspect the training or the design fit rather than capacity.
On CAT08, Jang and Jeon reported 1.94 mm (right) and 2.22 mm (left), from eight test cases on a different split. This work used four CAT08 volumes, and SwinUNETR-V2 and nnResUNet reached mean errors between 1.04 and 1.20 mm there. The authors caution that millimetre values depend on cohort, image resolution and ostium definition, and each model comes from one training run.
Training data decides reliability
nnResUNet is more robust in the same setting, with median errors of 1.33 and 1.03 mm. It still fails on 6.9% of right and 3.4% of left ostia, all in five ImageCAS volumes. Adding 250 ImageCAS volumes removes every failure and brings the median errors below 1 mm. The authors note that the architecture, loss and inference pipeline stayed the same, so the added data carries the gain.
Beyond 250 volumes, the models don't improve in a steady way. The models trained with 500 and 750 volumes failed on one and three ostia, mostly of ASOCA. With one training per arm, however, they can't separate the number of volumes from their annotations.
Trained on ImageCAS alone, SwinUNETR-V2 and nnResUNet localized the CAT08 and ASOCA volumes they had never seen. They produced one failure and two failures, respectively, across 72 volumes. Their median errors were 0.77–1.18 mm, compared to 0.66–0.91 mm on ImageCAS. The models therefore transfer to other scanners and centers at a slightly lower accuracy.
The reverse direction is harder, since models trained on CAT08 and ASOCA don't work well on ImageCAS. nnResUNet still failed on 8% of right and 4% of left ImageCAS ostia. Its median errors were 1.37 and 1.09 mm, compared to 0.70 and 0.87 mm when trained on the three datasets. The authors attribute this asymmetry to the number of annotated volumes more than to image similarity.
Their conclusion rests on 72 external volumes and a single training per model, so it's a limited claim.
Spacing and overlap as speed levers
Coarsening the spacing costs little accuracy for both models in this ablation. Neither SwinUNETR-V2 nor nnResUNet fails at any tested spacing up to 1.5 mm. SwinUNETR-V2 processing per patient drops from 55.6 s to 21.9 s at 1.0 mm. nnResUNet processing per patient drops from 41.1 s to 21.3 s, roughly half. At 1.5 mm the errors grow, while the time falls by at most 3 s more.
The authors therefore treat 1.0 mm as the coarsest spacing worth using.
The models tolerate only a small mismatch between training and inference spacing. The model trained at 1.0 mm doesn't fail at all, so the failures don't come from lost resolution. The authors attribute the failures to the change in apparent anatomical scale instead.
Sliding-window overlap matters little from 32 voxels upwards. An overlap of 32 voxels, instead of the default 64, makes SwinUNETR-V2 about 40% faster. The same overlap makes nnResUNet 24% faster than the default of 64 voxels. Removing the overlap altogether lowers accuracy, as the paper reports. The authors call an overlap of 32 voxels a good compromise between accuracy and speed.
Faster processing comes from training at a coarser spacing, not from resampling at inference.
Limitations of the labels, test set and benchmark
The ImageCAS volumes come from a single institution, while CAT08 and ASOCA add only 32 and 40 volumes. The ImageCAS cohort lists 586 male and 414 female patients, but the paper doesn't distribute patient gender with the images. So the annotations and benchmark results couldn't be stratified by gender.
The annotators were biomedical engineers, five master's students and one PhD student, rather than clinicians. For the second batch, Annotator 4 alone reviewed and corrected the candidates produced by a SwinUNETR-V2 model. These second-batch labels haven't been verified independently, so the test set comes only from the first batch. Because each candidate was inspected on the CCTA volume, the labels shouldn't differ materially from manual ones.
Still, the accepted candidates could favor SwinUNETR-V2, though nnResUNet reaching the same accuracy suggests the effect is small.
The annotation protocol assumes exactly one ostium per side, so the labels don't represent anatomical variants. Separate LAD and circumflex ostia, a single coronary ostium and anomalous origins all fall outside the labels. The behavior of the models on these variants hasn't been quantified.
A few branches missed in unflagged patients can't be excluded. The benchmark uses a limited set of architectures and one training recipe, with a single training run per model. Processing time was measured on a single GPU limited to 20 of its 40 GB, including image loading and export. Future work targets independent validation of the second batch and tests on anomalous origins and non-gated CT angiography.
Paper info
- Authors
- Matteo Leccardi, Andrea Moglia, Marco Morandini, Michele Brembilla, Alessandro Nicosia, Andrea Penserini, Christian Brandini, Ender Konukoglu, Marco Marcon, Luca Mainardi, Pietro Cerveri
- Venue
- arXiv · Preprint
- First published
- 2026-11-6
- Added
- 2026-11-9
- Updated
- 2026-11-6
- Version
- v1
- arXiv
- 2611.09714
- Category
- eess.IV · cs.CV
- Original paper terms
- CC BY 4.0
- What we show
- Paper info, commentary and permitted figures from the original paper
AI commentary is a separate explanation from the original paper and may contain errors. The original paper and figures follow each source's terms of use and any rights noted separately.
Abstract
Coronary ostia and centerlines are key reference points for automated analysis of coronary computed tomography angiography (CCTA), from surgical planning to intraoperative vessel tracking. However, the only public ostium annotations cover 77 non-gated aortic scans, not CCTA, while CAT08 and ASOCA (32 and 40 CCTA scans) mark the ostia only implicitly, as centerline start points. This work enriches ImageCAS, the largest public dataset for coronary artery segmentation, with ostium annotations for its 1000 patients and centerline graphs rooted at these new ostia, making it, to the authors' knowledge, the largest public dataset for ostium localization and the only one with centerlines following the official ImageCAS masks and starting at annotated ostia. Three annotators marked each ostium in the first 500 volumes; in the next 500, the candidates of a model trained on the first batch were corrected (human-in-the-loop). Six 3D localization models, trained on ImageCAS, CAT08 and ASOCA, were benchmarked on 58 held-out volumes (50 ImageCAS, 4 CAT08, 4 ASOCA). SwinUNETR-V2 and nnResUNet localized all ostia without failure (>5 mm error), with median errors of 0.70-0.87 mm. Trained on CAT08 and ASOCA alone, SwinUNETR-V2 fails on 34% of right and 53% of left ostia, whereas adding 250 ImageCAS volumes removes all failures. The centerlines were extracted by a deterministic, quality-controlled minimal-path procedure; on ASOCA, they cover a median of 99.5% of the reference length, with a median per-patient mean distance of 0.22 mm between matched reference points and centerlines. Annotations, centerlines, code, and weights are available at https://hal9000-lab.github.io/.
Quote from the paper
Matteo Leccardi, Andrea Moglia, Marco Morandini, Michele Brembilla, Alessandro Nicosia, Andrea Penserini, Christian Brandini, Ender Konukoglu, Marco Marcon, Luca Mainardi, Pietro Cerveri (2026). Beyond Segmentation: Enriching ImageCAS with Coronary Ostia Landmarks, Rooted Centerline Graphs, and Open-Weight Localization Models. arXiv:2611.09714v1. https://arxiv.org/abs/2611.09714v1
BibTeX
@misc{leccardi2026beyond,
title = {{Beyond Segmentation: Enriching ImageCAS with Coronary Ostia Landmarks, Rooted Centerline Graphs, and Open-Weight Localization Models}},
author = {Matteo Leccardi and Andrea Moglia and Marco Morandini and Michele Brembilla and Alessandro Nicosia and Andrea Penserini and Christian Brandini and Ender Konukoglu and Marco Marcon and Luca Mainardi and Pietro Cerveri},
year = {2026},
eprint = {2611.09714},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2611.09714v1}
}