Profile

Settings

Loading…

← Papers

Help

FAQ

Which features require signing in?

You can read the commentary, paper info, Model Structure and related papers of public papers without signing in. Sign in to manage your account or contact us about your inquiries.

Can I upload a PDF file?

Upload papers with an arXiv or DOI link; the commentary is public to everyone. Papers whose source and terms of use can't be verified, so the commentary can't be made public, can't be uploaded. Uploading PDF files and keeping papers private are for subscribers only, and a paper uploaded as a file is saved as private only. Searching for official info by title runs only when you press the button.

Are the figures and AI commentary accurate?

Figures come only from the original paper, and only those whose terms of use are verified are shown. The commentary is written by AI and may be wrong. Check important claims, numbers and figure context against the evidence in the original paper.

I want to report a copyright issue.

Terms of use and the source of the original paper are on the Paper info tab. If there's a problem, choose "Paper content, figures and copyright" under Contact us and send the paper link, the part in question, and evidence that you hold the rights. Receiving your report doesn't confirm any rights or remove anything right away. You can see the result of the review under My inquiries.

I forgot my password.

If you signed up with email, use Forgot password in the sign-in window to reset it with your verified email. If you signed up with Google, Naver or Kakao, change your password with that service.

What should I include in an inquiry?

Tell us which screen you were on and what you were doing when the problem happened, along with the paper link. Don't include personal information such as passwords, API keys, verification codes or phone numbers. Inquiries and replies are stored in Refivu and you can see them under My inquiries.

How do I delete my account?

In Settings, under My account, press Delete account. Review what will be deleted and complete identity verification to delete your account. For other requests, choose "Account" under Contact us.

Paper commentary

Benchmarking CNNs, Vision Transformers, and Foundation Models for Explainable Brain Tumor MRI Classification: Calibration, Decision Analysis, and External Validation

Duplicate-filtered tests reveal brain tumor MRI architecture differences

  • Problem Accuracy on popular brain tumor MRI benchmarks can look high because near-duplicate images and shared patients land on both sides of the split. Architecture rankings on those benchmarks may therefore not hold up.
  • Method The authors screen duplicates and shared patients out of the test data first, then fit every parameter on validation data only. They compare six models on four-class classification, including external validation on BDNeuro-MRI.
  • Results On 1,675 external images, accuracy ran from 77.61% for MedSigLIP-448 to 94.99% for ViT-L/16, while internal test accuracy did not separate the models.

Figure 2: Overview of the leakage-aware pipeline. Every fitted quantity (temperature, ensemble weights,
stacker and thresholds) is estimated on the validation…

Figure 2 :Overview of the leakage-aware pipeline. Every fitted quantity (temperature, ensemble weights, stacker and thresholds) is estimated on the validation set, and the predefined test set is evaluated once; shortcut tests, quantitative explainability, ablations, an exploratory decision analysis and duplicate-filtered external validation follow.

Original paper · CC BY 4.0 · Asare, Akwasi · Benchmarking CNNs, Vision Transformers, and Foundation Models for Explainable Brain Tumor MRI Classification: Calibration, Decision Analysis, and External Validation · Original paper figure · Extracted the figure area from page 12 of the original PDF.

Why public-benchmark accuracy misleads

Published work on public brain tumor MRI collections routinely reports accuracies of 95–99%. Those figures can be inflated, because near-duplicate slices and slices from the same patient can land on both sides of a split. Test sets are also often reused to choose models or thresholds, and differences between architectures are seldom tested for significance.

A high score can therefore reflect memorised images rather than a better model.

External validation looks like the natural fix, but it only helps when the external images are independent of the training data. Models can also latch onto acquisition or source cues instead of pathology, and internal test sets drawn from the same sources can't reveal that. The study therefore asks whether the four-class architecture ranking survives once duplicates and shared patients are removed from the test data.

Screening duplicates before any training

The pipeline fixes the data split before any model sees a label, using a perceptual hash followed by pixel-level checks. Every image is first compared by pHash, and all pairs with a Hamming distance of at most 6 bits become candidates. The correlation averages the mean-centred products of the two flattened thumbnails over 3,136 pixels, each divided by the product of their standard deviations.

Accepted pairs are merged into duplicate groups as connected components, so chains of matches end up in one group.

Exact duplicates are found separately by hashing the decoded grayscale pixels, so identical images are caught before any threshold is applied.

Each Kaggle image is attributed to the source collection whose perceptual hash is nearest, provided the distance is at most 8 bits. Figshare images carry patient identifiers, and the Kaggle images attributed to Figshare inherit them. The Training folder is then split by a stratified, group-aware five-fold scheme that merges duplicate components with patient identifiers.

Six models under one training recipe

The six models come from three families: two CNNs, two vision transformers and two foundation models. MedSigLIP-448 is the 448-pixel vision encoder of a SigLIP model, which replaces CLIP's softmax contrastive loss with a pairwise sigmoid loss. Each backbone keeps its published weights, gets a new four-way linear head, and is fine-tuned end to end.

All six models share one training protocol, so the test scores differ only through the architecture and its pretraining. Early stopping watches the validation loss with a patience of 5 epochs and a minimum improvement of 10 −4. The checkpoint with the highest validation accuracy is kept, so the test set never picks the checkpoint. Optimisers, learning rates and batch sizes still differ by model, and Table 5 lists them.

Input resolution also differs, at 224 pixels for most models, 256 for Swin-V2-S and 448 for MedSigLIP-448.

Training ran in bfloat16 mixed precision with a fixed seed of 42 on a single NVIDIA A100-SXM4-80GB GPU. Three extra runs act as controls: MedSigLIP at 224 pixels, ConvNeXt-V2-Tiny at 448 pixels, and a matched ConvNeXt-V2-Tiny run. The matched run uses MedSigLIP's batch size of 8 and its normalisation, so it isolates preprocessing and batch size from the architecture.

Training on the split from the screening step gives 4,523 training images and 1,093 validation images. Every fitted quantity, including temperature and ensemble weights, is estimated on the validation set only.

Internal accuracy hides the differences

On the full Testing folder, accuracy runs from 94.50% for Swin-V2-S to 95.56% for EfficientNetV2-M. Bootstrap intervals overlap, and no pairwise McNemar difference survives Holm correction, with the smallest adjusted p-value at 0.090. So on this folder the architectures can't be told apart, however the ranking is read.

Removing the duplicates and shared-patient images leaves 773 clean test images, and accuracy on them falls by 3.5 to 4.2 percentage points, to 90.30% to 91.72%. Validation accuracy also sits 2.8 to 4.1 percentage points above test accuracy for every run, which the authors link to the different source mix in the test folder.

Glioma is the weakest class for every model, with sensitivity between 0.823 and 0.843. Glioma accounts for most of each model's errors, mainly confused with meningioma. Source matters more than architecture: SARTAJ-derived images score 77.9–86.6%, while Br35H-derived images score 91.4–92.8%. The authors put the gap between sources at up to 22 percentage points, which is much larger than the spread between architectures.

Calibration and ensembles on the internal split

Temperature scaling divides the logits by one scalar, and here that scalar is fitted on validation predictions only. All fitted temperatures sit between 0.58 and 0.68, so the label-smoothed models were under-confident on validation data. Scaling sharpens the probabilities, which is why the fitted temperatures fall below one. The ConvNeXt-V2-Tiny ECE fell from 0.058 to 0.035 under the same procedure.

The gain doesn't carry over cleanly to the test set. Scaling slightly increases, or leaves unchanged, the Brier score and NLL on the test set. The authors attribute this to validation accuracy of 98 to 99%, which made the temperatures over-sharpen predictions on the harder test set.

Ensembles didn't beat the best single model on the internal test set. The validation-fitted weights concentrated on MedSigLIP-448, so the ensemble leaned on one model.

Decision curves as an exploratory check

The decision analysis asks what a prioritisation rule would gain at a re-weighted tumor prevalence of 10%. At that prevalence and a threshold probability of 0.10, net benefit for the five tabulated models falls between 0.0956 and 0.0987. The maximum possible value at this setting is 0.100, which is what prioritising every study would reach.

Read against that baseline, the models avoid 86 to 89 of every 100 unnecessary prioritisations. Per 1,000 studies, the models missed 0.7 to 4.4 tumors and generated 0 to 4.5 unnecessary prioritisations.

Table 20 lists the rows for five models, and Figure 19 shows the full curves for every model. The analysis is exploratory, so the curves describe operating characteristics under stated assumptions rather than a validated clinical rule. Its prevalences are illustrative, and the authors ran it retrospectively. They don't measure patient outcomes, so the gain in net benefit doesn't show that prioritisation would help patients.

External test on duplicate-filtered BDNeuro-MRI

BDNeuro-MRI looks like an independent dataset, but its images largely repeat the Kaggle composite the models were trained on. No image repeats inside BDNeuro-MRI itself, so the authors kept the remaining images as the primary external set. Removing both the verified duplicates and the hash candidates gives the strict set of 1,485 images, which the authors use as a check.

The primary set of 1,675 images contains 862 glioma, 306 meningioma, 222 no tumor and 285 pituitary tumor images.

On this set the architectures separate widely, with ViT-L/16 at 94.99% and MedSigLIP-448 at 77.61%. Twelve of the 15 pairwise differences are significant after Holm correction, while none were significant on the internal test set. MedSigLIP-448's sensitivity drops to 0.679 for glioma and 0.674 for pituitary tumors, and its no-tumor specificity falls to 0.777.

Its calibration error rises to 0.205, so its errors come with high confidence.

The validation-fitted weighted ensemble gives MedSigLIP-448 a weight of 0.71, and it collapses to 78.33%. The simple average and majority vote fit no parameters, and they match the best model at 94.99%. All conclusions hold on the strict set, where accuracies sit 0.3 to 0.9 percentage points lower.

Explanations and shortcut checks

Attribution methods were scored against expert Figshare tumor masks, but only 165 test images have pixel-aligned masks. Only 6 of those 165 images belong to the clean subset, so the localisation analysis can't be stratified by leakage status. Grad-CAM's pointing-game hit rate is 0.139 for EfficientNetV2-M and 0.255 for ConvNeXt-V2-Tiny, against a chance energy level of 0.016.

Energy inside the mask is 0.085 for EfficientNetV2-M and 0.095 for ConvNeXt-V2-Tiny under Grad-CAM, so the maps put only a small share of their weight on the lesion. For most model and method pairs, the energy inside the mask is only a few times the chance level, so the maps localise poorly.

The model-randomisation check gives a different picture: it passes for several models, because it measures how far Grad-CAM maps move when the network is progressively re-initialised. Re-initialising the head and later stages pushes the Grad-CAM rank correlation towards zero or below it. For EfficientNetV2-M the correlation reaches -0.696 with only the head randomised.

The ConvNeXt-V2-Tiny correlation stays at 0.546 with the head randomised, so its maps change less than those of EfficientNetV2-M.

The source shortcut test asks whether the learned representations still carry information about the collection of origin. MedSigLIP-448 embeddings predicted the source collection with 86.4% accuracy, the highest of the models examined.

Limitations of the external set, splits and explanations

The external evaluation rests on the 1,675 non-duplicate BDNeuro-MRI images from a single dataset. So the external test is a partially independent check rather than a multicentre validation. Patient identifiers exist only for the Figshare images. For SARTAJ, Br35H and unmatched images, duplicate screening reduces but cannot remove correlated neighbouring slices across partitions.

The clean subset that reduces test overlap is small for some sources.

The authors kept the predefined test folder for comparability, even though it overlaps the training data.

Expert tumor masks exist only for Figshare tumor images, and only 6 of them belong to the clean subset. So the localisation analysis couldn't be stratified by leakage status.

The validation partition comes from the Training folder and is distributed differently from the test folder. The decision analysis is retrospective, uses illustrative prevalences and doesn't measure patient outcomes.

Paper info

Authors
Asare, Akwasi
Venue
arXiv · Preprint
First published
2026-11-9
Added
2026-11-10
Updated
2026-11-9
Version
v1
arXiv
2611.11793
Category
cs.CV
Original paper terms
CC BY 4.0
What we show
Paper info, commentary and permitted figures from the original paper

AI commentary is a separate explanation from the original paper and may contain errors. The original paper and figures follow each source's terms of use and any rights noted separately.

Abstract

Deep learning models for brain tumor MRI classification are usually compared by accuracy alone, on public datasets whose independence is rarely checked. We benchmarked six architectures: two convolutional networks (EfficientNetV2-M and ConvNeXt-V2-Tiny), two vision transformers (Swin-V2-S and ViT-L/16), and two foundation models (DINOv2-L and MedSigLIP-448), for four-class classification of 7,216 public MRI images. We assessed accuracy, calibration, explainability, ensembles, and decision curves, with every fitted quantity estimated on validation data only. Pixel-verified duplicate screening showed that 36% of the test images had a near-duplicate in the training data. Test accuracy ranged from 94.5% to 95.6%, with no pairwise difference after Holm correction, and fell to 90.3% to 91.7% on the 773 test images free of duplicates and shared patients. Ensembles did not outperform the best single model. Attribution maps passed a model-randomization test but localized expert-annotated tumors poorly. On 1,675 external BDNeuro-MRI images that did not duplicate the training data, accuracy ranged from 77.6% (MedSigLIP-448) to 95.0% (ViT-L/16), and 12 of 15 pairwise differences were significant. Internal accuracy on this public collection therefore did not distinguish the architectures, whereas the duplicate-filtered external test did.

Figures from the paper

Quote from the paper

Asare, Akwasi (2026). Benchmarking CNNs, Vision Transformers, and Foundation Models for Explainable Brain Tumor MRI Classification: Calibration, Decision Analysis, and External Validation. arXiv:2611.11793v1. https://arxiv.org/abs/2611.11793v1

BibTeX
@misc{akwasi2026benchmarking,
  title = {{Benchmarking CNNs, Vision Transformers, and Foundation Models for Explainable Brain Tumor MRI Classification: Calibration, Decision Analysis, and External Validation}},
  author = {Asare, Akwasi},
  year = {2026},
  eprint = {2611.11793},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.11793v1}
}

See related papersBrowse other papers

Paper preview
Account security

Connect Google account

If you connect a Google account, you can sign in with it too.

Refivu

Delete account

Refivu
Refivu

Sign up