Profile

Settings

Loading…

← Papers

Help

FAQ

Which features require signing in?

You can read the commentary, paper info, Model Structure and related papers of public papers without signing in. Sign in to manage your account or contact us about your inquiries.

Can I upload a PDF file?

Upload papers with an arXiv or DOI link; the commentary is public to everyone. Papers whose source and terms of use can't be verified, so the commentary can't be made public, can't be uploaded. Uploading PDF files and keeping papers private are for subscribers only, and a paper uploaded as a file is saved as private only. Searching for official info by title runs only when you press the button.

Are the figures and AI commentary accurate?

Figures come only from the original paper, and only those whose terms of use are verified are shown. The commentary is written by AI and may be wrong. Check important claims, numbers and figure context against the evidence in the original paper.

I want to report a copyright issue.

Terms of use and the source of the original paper are on the Paper info tab. If there's a problem, choose "Paper content, figures and copyright" under Contact us and send the paper link, the part in question, and evidence that you hold the rights. Receiving your report doesn't confirm any rights or remove anything right away. You can see the result of the review under My inquiries.

I forgot my password.

If you signed up with email, use Forgot password in the sign-in window to reset it with your verified email. If you signed up with Google, Naver or Kakao, change your password with that service.

What should I include in an inquiry?

Tell us which screen you were on and what you were doing when the problem happened, along with the paper link. Don't include personal information such as passwords, API keys, verification codes or phone numbers. Inquiries and replies are stored in Refivu and you can see them under My inquiries.

How do I delete my account?

In Settings, under My account, press Delete account. Review what will be deleted and complete identity verification to delete your account. For other requests, choose "Account" under Contact us.

Term

expected calibration error

Meaning

A calibration measure that groups predictions into bins by their stated probability, compares the mean probability with the observed accuracy in each bin, and averages those gaps weighted by bin size. Lower values indicate closer agreement between stated probability and correctness.

Source Can decision models extract clinical data from cancer pathology reports? An evaluation of accuracy, calibration, and failure modes

How papers use it 11 papers

  1. Can decision models extract clinical data from cancer pathology reports? An evaluation of accuracy, calibration, and failure modes

    Use Computed over 10 equal-width bins of the probability each decision model gave to its chosen option, pooled over all fields. It gave 0.022 for Nimble 9B and 0.026 for Tev1 4B. Within single fields it was much higher for some fields, such as Tev1 bone invasion at 0.370.

  2. A First Look at System One Decision Models for Malware Detection

    Use Reports how well the scores of each arm match observed outcomes, computed with 15 bins on the test split and listed next to AUROC and the TPR at a 1% FPR threshold. It is paired with the negative log-likelihood and the Brier score, and it serves as the calibration check for the decision scores.

    Meaning A calibration metric that groups predictions into confidence bins and averages the absolute gap between the mean predicted probability and the observed positive rate in each bin, weighted by the share of samples in that bin. A value near zero means that stated probabilities match observed frequencies.

  3. Calibrate, Don't Retrain: Decomposing the Value of Annotator Disagreement in Cyberbullying Severity

    Use Appears in the background on calibration under disagreement as a metric that Baan et al. argue is unsound when humans disagree. Its reference point is the majority label, which stops being a valid reference when annotators split. The study does not report ECE itself and instead scores calibration with total variation, the Brier score and the log score against the full annotator label distribution.

    Meaning A calibration metric that measures how far a model's confidence departs from its accuracy, so that a well-calibrated model has confidence that matches how often it is right.

  4. On Calibration of Modern Neural Networks

    Use The paper's primary metric, computed with M = 15 bins in Table 1.

    Meaning A summary of miscalibration that averages the accuracy-confidence gap over confidence bins, weighted by bin size.

  5. A Matching Lower Bound for Online Smooth Calibration

    Use Introduced as the most widely used calibration measure and used as a point of comparison. The paper uses an example in which predicting \(1/2\) in every round gives zero ECE, while tiny perturbations of the forecasts make every round its own bin and drive ECE up to order \(T\). This motivates smooth calibration error, which stays small in the same example. ECE is not used to derive the lower bounds in the paper.

    Meaning The \(\ell_1\) calibration measure that groups rounds by identical forecast values. For each distinct value \(\alpha\), it takes the absolute value of the sum of residuals \(x_t-p_t\) over the rounds with \(p_t=\alpha\), and then sums these absolute values over all \(\alpha\). Each distinct forecast value forms its own bin, so the measure is discontinuous in the forecasts.

  6. Tabular Foundation Models vs Tuned Gradient Boosting for Telecom Churn: A Profit- and Calibration-Aware Evaluation

    Use Used with 15 equal-width bins to check whether predicted churn probabilities match observed churn, both for raw model outputs and after isotonic regression or Platt scaling. These calibration checks are kept apart from the ranking and profit metrics.

    Meaning A calibration measure that splits predicted probabilities into equal-width bins and compares the average predicted probability with the observed event rate in each bin, then averages the gaps across bins weighted by how many cases fall in each bin.

  7. Supervised Contrastive Learning

    Use Averaged over the ImageNet-C corruptions at each severity level and reported for ResNet-50 and ResNet-200 models trained with cross-entropy and with SupCon. Calibration is examined as corruption severity grows, alongside top-1 accuracy at each severity.

    Meaning A calibration metric that measures how well a model's predicted confidence matches its actual accuracy, computed as a gap between the two. Lower values indicate better calibration.

  8. Dynamic bigraphical Matérn--Whittle processes: learning dependence graphs among spatial-temporal fields

    Use Measures calibration of the inclusion probabilities over ten bins.

    Meaning A summary of the gap between predicted probabilities and observed frequencies, averaged over bins.

  9. Small Heads, Strong Decisions: A Controlled Study of Typed-Decision Models

    Use The paper uses it alongside NLL to check whether calibration fixes confidence errors, and notes that held-out ECE is higher under bidirectional attention than under causal attention.

    Meaning A calibration metric that splits predictions into bins by confidence and averages the gap between accuracy and mean confidence across bins, weighted by how many predictions fall in each bin. Lower values indicate that stated confidence better matches how often predictions are correct.

  10. ShadowTransfer: A Geographic Transfer Benchmark for Overhead Shadow Detection

    Use Reported separately for predicted-positive and predicted-negative pixels.

    Meaning A measure of the gap between predicted confidence and observed accuracy, averaged over confidence bins.

  11. Benchmarking CNNs, Vision Transformers, and Foundation Models for Explainable Brain Tumor MRI Classification: Calibration, Decision Analysis, and External Validation

    Use Used to assess how well each model's confidence matches its accuracy, using equal-width bins. On validation data, temperature scaling lowered the ECE for most runs, for example for ViT-L/16 and ConvNeXt-V2-Tiny, and the calibration error of the external BDNeuro-MRI predictions is reported separately.

    Meaning Expected calibration error (ECE) is a calibration metric that groups predicted confidences into bins and averages the gap between each bin's mean confidence and its observed accuracy. Lower values indicate that stated probabilities match how often predictions are correct.

Related terms

Open in the term mapTerm list

Paper preview
Account security

Connect Google account

If you connect a Google account, you can sign in with it too.

Refivu

Delete account

Refivu
Refivu

Sign up