Profile

Settings

Loading…

← Papers

Help

FAQ

Which features require signing in?

You can read the commentary, paper info, Model Structure and related papers of public papers without signing in. Sign in to manage your account or contact us about your inquiries.

Can I upload a PDF file?

Upload papers with an arXiv or DOI link; the commentary is public to everyone. Papers whose source and terms of use can't be verified, so the commentary can't be made public, can't be uploaded. Uploading PDF files and keeping papers private are for subscribers only, and a paper uploaded as a file is saved as private only. Searching for official info by title runs only when you press the button.

Are the figures and AI commentary accurate?

Figures come only from the original paper, and only those whose terms of use are verified are shown. The commentary is written by AI and may be wrong. Check important claims, numbers and figure context against the evidence in the original paper.

I want to report a copyright issue.

Terms of use and the source of the original paper are on the Paper info tab. If there's a problem, choose "Paper content, figures and copyright" under Contact us and send the paper link, the part in question, and evidence that you hold the rights. Receiving your report doesn't confirm any rights or remove anything right away. You can see the result of the review under My inquiries.

I forgot my password.

If you signed up with email, use Forgot password in the sign-in window to reset it with your verified email. If you signed up with Google, Naver or Kakao, change your password with that service.

What should I include in an inquiry?

Tell us which screen you were on and what you were doing when the problem happened, along with the paper link. Don't include personal information such as passwords, API keys, verification codes or phone numbers. Inquiries and replies are stored in Refivu and you can see them under My inquiries.

How do I delete my account?

In Settings, under My account, press Delete account. Review what will be deleted and complete identity verification to delete your account. For other requests, choose "Account" under Contact us.

Paper commentary

CellPlex: Benchmarking Single-Cell Spatial Proteomics Prediction from H&E

CellPlex benchmark shows H&E predicts single-cell proteins only within cohort

  • Problem Virtual staining models were each scored on their own cohort, panel and pixel-level metric, so their accuracies could not be compared. Released models also transfer poorly to new cohorts.
  • Method CellPlex is a benchmark that fixes the cells, targets and splits. Pathology foundation models are adapted with one cell-level head, and specialist models are fine-tuned under a matched budget.
  • Results CELLO with H-optimus-0 scored a mean PCC of 0.532 across seven cohorts, compared to 0.460 for fine-tuned Eva.

Figure 1: Overview of CellPlex. Left: the seven cohorts with their cells after quality control, patients, samples and proteins, and the
construction of per-cel…

Figure 1 . Overview of CellPlex. Left: the seven cohorts with their cells after quality control, patients, samples and proteins, and the construction of per-cell targets, in which nuclei segmented on the H&E are grown into cell regions and the registered multiplexed image is averaged over each region. Right: the evaluated models, pathology foundation models adapted with a cell-level protocol and two specialist models, Eva and GigaTIME, whose pixel-level outputs are averaged over the same cell regions.

Original paper · CC BY 4.0 · Zijun Gao, Yijiang Chen, Xiangde Luo, Pheng-Ann Heng · CellPlex: Benchmarking Single-Cell Spatial Proteomics Prediction from H&E · Original paper figure · Extracted the figure area from page 2 of the original PDF.

Why H&E models can't be compared yet

H&E slides, by contrast, exist for nearly every patient, so predicting proteins from them could bring these analyses to routine pathology.

Several model families now pursue this prediction by learning from paired H&E and multiplexed images. Image-to-image translators predict a fixed panel, while PFM-based predictors build on foundation models for the same task. GigaTIME was trained on 21 whole slides and ROSIE on 1,342 cores, so the training corpora differ in size and form. HistoPlexer was trained on 336 regions from a single cohort, and MIPHEI-ViT on Orion-CRC alone.

In the spora benchmark, GigaTIME, HistoPlexer and ROSIE were applied as released to four cohorts and scored pixel by pixel. Averaged over the markers all three predict, Pearson correlation remained under 0.11 in each model and cohort pairing. SSIM ranked the same models differently, so the two metrics disagreed about which model performed best.

On the Hickey et al. intestine cohort, HistoPlexer reached the highest SSIM at 0.60. Its predictions were uncorrelated with the measurements, with a Pearson correlation of 0.004.

Without a shared cell-level setup, a reader can't tell which approach to build on.

Building per-cell targets from paired sections

CellPlex starts from seven public cohorts in which H&E and multiplexed immunofluorescence were imaged on one tissue section. Together, these cohorts hold 717 samples, 44.8 million cells and 149 proteins, all processed by one pipeline. Glioma adds 30 patients imaged on PhenoCycler-Fusion at 0.25 to 0.51 µm/px, with 68 proteins.

The pipeline segments nuclei on the H&E with CellViT++ at about 0.25 µm/px, then maps the contours back to each native pixel grid. The key choice is to segment on the H&E rather than the multiplexed image, so every target belongs to a cell the model can see at inference. Each nucleus is grown by 2 µm into a region that doesn't enter its neighbours.

The target for protein p is log(1 + x̄), where x̄ is the mean intensity of that channel over the nucleus region.

On the CODEX arrays the H&E sits on the same microscope grid, so the authors estimate a translation per core. BC/CRC's H&E already lies on the CODEX grid, while Orion-CRC and bone marrow come registered to the H&E in their release. Glioma's H&E was scanned on another microscope, so it needs a coarse rigid search, an affine alignment and a smoothed displacement field on 260 µm tiles.

A misregistered sample loses this contrast, so samples below 0.8 are excluded. This rule removes 10 CRC-TMA cores and one BC/CRC region, along with a few samples from other cohorts. Most cohorts use five folds, while Orion-CRC and glioma use one fixed patient-level split instead.

Turning a foundation model into a cell-level predictor

The head reads a pathology foundation model's features and returns one protein vector for each nucleus. Each H&E image is cut into non-overlapping tiles at the cohort's native resolution, with tile side L set to 224. The PFM encodes each tile into a class token and a token map, whose grid size follows from the tile side divided by the patch size.

Because the same PFM and training recipe are used in every run, differences in accuracy can be attributed to the encoder.

For a nucleus at position s_i, the query is sampled bilinearly from the token map at that position. The query then attends to all tokens of its tile through a cross-attention layer with 2-D rotary position embeddings. A distance-decay bias lowers the attention weight of tokens whose centers lie far from the nucleus. The layer-normalized output is fused with the class token by a residual attention layer, so the head keeps tile-level context.

A two-layer MLP with ReLU output then maps the fused feature to the P proteins of the panel.

Training minimizes a Huber loss over the cells and adds 0.5 times the Huber loss of a second head. That second head predicts the summed target of all cells in the tile from the class token. Three PFMs go through this head: UNI2-h and Virchow2, both ViT-H/14, and H-optimus-0, a ViT-g/14.

The probe maps these features to the panel with ridge regression, and the regularization strength is chosen on the validation samples. On H-optimus-0, the linear probe reaches a mean PCC of 0.446, which shows how much the frozen features already carry.

Specialist models under a matched budget

Eva and GigaTIME were run with their released weights, so neither model was retrained before the zero-shot scores. Because every model is scored on identical regions and targets, the comparison with the CELLO-adapted PFMs stays on the same cells.

Eva takes H&E as three further input channels, and the benchmark uses the checkpoint its authors fine-tuned for H&E-to-multiplex prediction.

The fine-tuning runs separate what a specialist's architecture and pretraining contribute from its exposure to the test domain. Eva trains all parameters with its authors' mean-squared error objective on the multiplexed channels predicted from H&E alone.

Under this matched budget, CELLO with H-optimus-0 reaches a mean PCC of 0.532, against 0.460 for fine-tuned Eva. Fine-tuned GigaTIME reaches 0.30 to 0.43 PCC and sits below CELLO with H-optimus-0 on 656 of the 657 test samples.

Adapted PFMs against specialists

CELLO with H-optimus-0 scored a mean PCC of 0.532 over the seven cohorts, compared to 0.460 for fine-tuned Eva and 0.344 for fine-tuned GigaTIME.

Fine-tuned Eva came closest on the Multi-tumor array, at 0.419 compared to 0.443 for CELLO. On glioma the gap was widest, with fine-tuned Eva at 0.365 compared to 0.503 for CELLO.

Fine-tuned GigaTIME scored 0.30 to 0.43, and CELLO was higher on 656 of the 657 test samples.

Linear probes and zero-shot specialists

A linear probe on frozen H-optimus-0 features reaches a mean PCC of 0.446, which sits close to the 0.460 of fine-tuned Eva. The probe beats Eva on Orion-CRC, at 0.590 against 0.500, and on glioma, at 0.413 against 0.365. Its mean SSIM is higher as well, at 0.391 against 0.329, so the frozen encoder carries much of the signal. The frozen features already encode much of the protein signal, and the probe gives new methods a cheap reference point.

Adapting the encoder with CELLO adds 0.03 PCC on Orion-CRC, rising to 0.11 on BC/CRC, over the linear probe. CELLO is better than the probe on 646 of the 657 test samples, so the gain holds across most samples. Because the gain stays consistent across cohorts, the cell-level head matters on top of the frozen encoder.

Zero-shot GigaTIME has a negative correlation on bone marrow, so its transfer is weakest there.

On six of the seven cohorts, the gain from fine-tuning Eva exceeds its remaining gap to CELLO with H-optimus-0. That remaining gap is 0.28 against 0.07 on average, so the fine-tuning gain is the larger effect here.

Which foundation model adapts best

H-optimus-0 is the strongest of the three PFMs once CELLO is applied to each of them. Its margins over UNI2-h are 0.005 to 0.018 PCC, and over Virchow2 they are 0.012 to 0.025. These margins are small next to the 0.03 to 0.11 PCC that CELLO adds over the linear probe. The authors read the consistency of these margins across cohorts as a sign that CellPlex can separate encoders of similar accuracy.

Compared to UNI2-h, H-optimus-0 scores higher on 67% of the test samples in glioma and on 100% in bone marrow. That difference is significant on every cohort except glioma, where it holds on 6 of 9 sections with p of 0.074. Compared to Virchow2, H-optimus-0 scores higher on every cohort, with p of at most 0.008. Averaged over the seven cohorts, CELLO reaches a PCC of 0.532 with H-optimus-0, 0.519 with UNI2-h and 0.512 with Virchow2.

The ranking changes under transfer, because UNI2-h edges out H-optimus-0 when models move to another cohort. UNI2-h reaches a mean PCC of 0.226 in transfer, against 0.219 for H-optimus-0. Virchow2 is lowest in transfer, at 0.202. That gap is small, so the transfer ranking of the three encoders is close.

Transfer between cohorts

Transfer asks whether a model trained on one cohort keeps its accuracy on another cohort without further training. Scores were computed only on the proteins that the two panels share, over 42 pairs of cohorts.

Over the 42 pairs, CELLO with H-optimus-0 averaged a PCC of 0.22 on the shared proteins. The target cohort's own models reached 0.52 on the same proteins and cells, so the transferred model kept 41% of that accuracy on average. Eva used as released reached 0.21 on the same proteins, yet the transferred CELLO model beat it on only 20 of the 42 pairs.

Transfer worked only between closely related cohorts. Glioma was the hardest target: from any other cohort the model reached at most 0.15, against 0.46 when trained on glioma.

Trained on BC/CRC, the model reached 0.47 on Orion-CRC, another colorectal cohort, against 0.61 in-domain. UNI2-h transferred slightly better than H-optimus-0, with a mean PCC of 0.226 against 0.219. Virchow2 came last at 0.202, so the three encoders transferred within a narrow band. The authors read this pattern as the adapted models learning largely cohort-specific mappings from H&E to protein levels.

Adapted PFMs keep under half of their accuracy on cohorts they were not trained on, so transfer is the weakest result here. Transfer to cohorts without paired data remains open, as the authors put it. Paired data from the target cohort stays the main lever for accuracy in this benchmark.

Which proteins are predictable from H&E

Its per-protein spread runs from 0.38 to 0.71 PCC on CRC-TMA and from 0.16 to 0.84 on glioma. CD3 reaches 0.66 on Orion-CRC but only 0.20 on glioma, so the same marker can be easy in one tissue and hard in another. Ki67 reaches 0.74 on bone marrow but 0.30 on Multi-tumor, which shows the ranking shifts with the tissue. Splitting the variance with a two-way analysis of variance gives 32% to the protein, 21% to the cohort and 47% to their interaction.

The number of cells measured for a protein doesn't predict its accuracy. Across all cohorts, the Spearman ρ between cell count and mean PCC is −0.11 over 149 proteins. Spatial autocorrelation, measured as Moran's I over the 10 nearest cells, tracks accuracy instead. Across 341 cohort–protein pairs, CELLO's protein PCC has a Spearman correlation of 0.36 with Moran's I.

Proteins in the upper two quintiles of Moran's I reach 0.57 PCC, against 0.46 to 0.47 in the lower two.

Figure 3: What makes a protein predictable, over the 341 cohort–protein pairs of the benchmark. Top: protein PCC against the spatial
autocorrelation of the mea…

Figure 3 . What makes a protein predictable, over the 341 cohort–protein pairs of the benchmark. Top: protein PCC against the spatial autocorrelation of the measured protein (Moran’s I over the 10 nearest cells); lines: median and interquartile range per quintile of Moran’s I; ρ: Spearman correlation. Bottom left: median protein PCC per quintile of sparsity (Gini coefficient), dynamic range (99th minus 50th percentile of the measured level) and Moran’s I. Bottom right: protein PCC by subcellular localization; boxes: interquartile range and median, whiskers: 5th–95th percentile;n: cohort–protein pairs.

Original paper · CC BY 4.0

The linear probe follows the same trend, with ρ = 0.37. Fine-tuned Eva and GigaTIME depend less on Moran's I, with ρ of 0.08 and 0.17.

Sparsity and dynamic range don't change CELLO's accuracy (Kruskal–Wallis p ≥ 0.3). Subcellular localization doesn't change it either (p = 0.2), with membrane, cytoplasmic, nuclear and secreted proteins at median PCCs of 0.51 to 0.55. The authors read this as H&E being most informative about proteins whose levels follow tissue architecture.

Where the predicted signal sits in the tissue

Figure 2 shows held-out samples from three cohorts, two per cohort, with the H&E, the measured protein and each model's prediction side by side. Each panel is scaled to the 1st to 99th percentile of its cells in the view. CELLO with H-optimus-0 reproduces the CD20 B-cell follicles of Orion-CRC and the CD21 follicle of a CRC-TMA core. It also picks out clustered PD-1-high and CDX2-high cells, and the CXCL12-high rings and TNC pattern of HNSCC lymph-node cores.

Its boundaries sit at the level of single nuclei, with r from 0.68 to 0.83.

Figure 2: Protein maps on held-out samples of three cohorts, two per cohort (four more cohorts in Fig. S3). Each case shows the H&E of one
view and its cells c…

Figure 2 . Protein maps on held-out samples of three cohorts, two per cohort (four more cohorts in Fig. S3). Each case shows the H&E of one view and its cells colored by one protein, as measured and as predicted by CELLO (H-optimus-0) and by fine-tuned Eva and GigaTIME; the inset magnifies the boxed region. Every panel is scaled to the 1st–99th percentile of its cells in the view; scale bar, 100µm.

Original paper · CC BY 4.0

Eva spreads CD20 over the epithelium of Orion-CRC instead of confining it to the follicles. GigaTIME predicts PD-1 across most of the Orion-CRC view. Both specialists assign high CD21 outside the CRC-TMA follicle. These fine-tuned maps are at best uncorrelated with the measurements, with r from −0.55 to 0.00.

The authors read these errors as a question of which structures carry the signal, not of spatial resolution. The paper concludes that H&E is most informative about proteins whose levels follow tissue architecture.

Figure 2 shows two samples per cohort, and Fig. S3 holds two more for each of the other four cohorts. Part of a protein's cell-to-cell variation may not show up in H&E at all. They didn't test how close current models come to this ceiling for proteins that vary between neighboring cells.

Limitations and open problems of CellPlex

The authors name three open problems after the benchmark, and the first is transfer between cohorts. A model trained on one cohort therefore predicts only the proteins of its own panel.

The third constraint is a ceiling set by the targets themselves. The targets are multiplexed immunofluorescence measurements, so their noise bounds the score that any model can reach. The authors don't know how close current models come to this ceiling, especially for proteins that vary between neighboring cells.

The benchmark covers only some tissues and diseases, with seven cohorts on two imaging platforms. They don't test downstream usefulness in this work, which they list as a future direction.

The conclusion reads these limits as a map of where H&E falls short today. The authors point to three directions: models trained on many paired cohorts, models that capture variation between neighboring cells, and evaluations in downstream tasks.

Paper info

Authors
Zijun Gao, Yijiang Chen, Xiangde Luo, Pheng-Ann Heng
Venue
arXiv · Preprint
First published
2026-11-2
Added
2026-11-4
Updated
2026-11-2
Version
v1
arXiv
2611.02506
Category
cs.CV
Original paper terms
CC BY 4.0
What we show
Paper info, commentary and permitted figures from the original paper

AI commentary is a separate explanation from the original paper and may contain errors. The original paper and figures follow each source's terms of use and any rights noted separately.

Abstract

Spatial proteomics measures tens of proteins in every cell of a tissue section, but its cost confines it to small research cohorts, whereas hematoxylin and eosin (H\&E) slides exist for nearly every patient. Inferring single-cell spatial proteomics from H\&E would bring its analyses to routine pathology, and a growing number of virtual staining models pursue this goal. Each is evaluated on its own cohort, panel and pixel-level metric, and released models transfer poorly to new cohorts, leaving open which approach to build on and which proteins H\&E can reveal. We introduce CellPlex, a benchmark that poses the task at the level of the cell: seven cohorts with same-section H\&E and multiplexed immunofluorescence, from colorectal and breast cancer to lymph-node metastases, bone marrow and glioma, with 717 samples, 44.8 million cells and 149 proteins, processed by one pipeline into per-cell targets. Pathology foundation models (PFMs) are adapted with one cell-level protocol, specialist models are fine-tuned under a matched budget, and all are scored on the same cells. Adapted PFMs are the most accurate models on every cohort, ahead of the specialists even after fine-tuning, but keep less than half of their accuracy on cohorts they were not trained on. Which proteins can be predicted depends on the tissue, not on how many cells were measured for them. By fixing the cells, targets and splits on which predictions are judged, CellPlex sets a common standard for inferring costly molecular measurements from routine H\&E and shows how far H\&E can stand in for spatial proteomics. We will release the data, splits, evaluation code and baselines as a testbed for developing and comparing future pathology foundation models and virtual staining methods.

Quote from the paper

Zijun Gao, Yijiang Chen, Xiangde Luo, Pheng-Ann Heng (2026). CellPlex: Benchmarking Single-Cell Spatial Proteomics Prediction from H&E. arXiv:2611.02506v1. https://arxiv.org/abs/2611.02506v1

BibTeX
@misc{gao2026cellplex,
  title = {{CellPlex: Benchmarking Single-Cell Spatial Proteomics Prediction from H&E}},
  author = {Zijun Gao and Yijiang Chen and Xiangde Luo and Pheng-Ann Heng},
  year = {2026},
  eprint = {2611.02506},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.02506v1}
}

See related papersBrowse other papers

Paper preview
Account security

Connect Google account

If you connect a Google account, you can sign in with it too.

Refivu

Delete account

Refivu
Refivu

Sign up