Paper commentary
Multimodal Machine Learning-based Knee Osteoarthritis Progression Prediction from Plain Radiographs and Clinical Data
- Problem Existing knee OA progression models rely on observer-derived measures and are rarely validated on external data, which makes their performance hard to judge.
- Method Trains a multi-task CNN on raw baseline knee radiographs, then fuses its outputs with clinical variables in a gradient boosting model.
- Results The fused model with KL grade reached AUC 0.80 (0.79-0.82) and AP 0.70 (0.68-0.72) on the MOST test set.

Figure 1 . Schematic representation of our multi-modal pipeline, predicting the risk of osteoarthritis (OA) progression for a particular knee. We first use a Deep Convolutional Neural Network (CNN), trained in a multi-task setting to predict the probability of OA progression (no progression, rapid progression, slow progression) and the current stage of OA defined according to the Kellgren-Lawrence (KL) scale. Subsequently, we fuse these predictions with patient’s Age, Sex, Body-Mass Index, given knee injury and surgery history, symptomatic assessment results and, optionally, a KL grade given by a radiologist using a Gradient Boosting Machine Classifier. After obtaining prediction from CNN, we utilize GradCAM attention maps to make our method more transparent and highlight the zones in the input knee radiograph, which were considered most important by the network.
Original paper · CC BY 4.0 · Aleksei Tiulpin, Stefan Klein, Sita M. A. Bierma-Zeinstra, Jérôme Thevenot, Esa Rahtu, Joyce van Meurs, Edwin H. G. Oei, Simo Saarakkala · Multimodal Machine Learning-based Knee Osteoarthritis Progression Prediction from Plain Radiographs and Clinical Data · Original paper figure · Extracted the figure area from page 3 of the original PDF.Why progression is hard to predict
Knee osteoarthritis has no effective treatment beyond behavioral interventions, and at the late stage the main option is total knee replacement, which is invasive and costly. Prognosis matters both for planning therapy and for selecting patients for disease-modifying drug trials, yet the widely available diagnostic tools give weak prognosis.
Existing progression models combine image texture descriptors, KL grade and clinical data, but their performance and generalizability are hard to judge. Three weaknesses stand out: texture features depend on acquisition settings, few studies validate on an external dataset, and many models score joint space width loss rather than a broader outcome.
The study changes both the input and the outcome. The model reads the raw baseline knee radiograph instead of measures derived by observers, and it predicts whether a knee with no, early or moderate OA will show a KL-grade increase or need knee replacement within 7 years. To the authors' knowledge, no earlier study had used CNNs to predict OA progression directly from radiographs.
The radiologist's KL grade is only an optional input, so the fully automatic version does not need it. The overall pipeline is shown schematically in Figure 1.
Cohorts and progression labels
Training uses knees from the Osteoarthritis Initiative (OAI) and testing uses knees from the Multicenter Osteoarthritis Study (MOST). Only knees with KL-0, KL-1, KL-2 or KL-3 at baseline were kept, and test-set subjects who died between follow-ups were removed. After pre-selection, the training set has 4,928 knees from 2,711 subjects and the test set has 3,918 knees from 2,129 subjects.
Progressors make up 1,331 (27%) of the OAI knees and 1,501 (47%) of the MOST knees.
Progression means an increase in KL grade. The step from KL-0 to KL-1 is ignored, and progression to knee replacement is included. Three classes are defined: y = 0 for no progression, y = 1 for progression within the next 60 months, and y = 2 for progression after 60 months. Knees with a knee replacement or KL-4 at baseline, or with missing baseline KL data, were excluded, and when a knee progressed more than once the earliest recorded KL increase set its class.
The reference models pool y = 1 and y = 2 into a single binary outcome.
The cohorts cover subjects aged 45-79 years in OAI and 50-79 years in MOST, followed up to 96 months and 84 months. OAI images were taken with a SynaflexerTM frame at a 10 degree beam angle, while MOST also includes images at 5 and 15 degree beam angles, and the authors include such data in the test set.
From DICOM to network input
BoneFinder localizes bone landmarks, and a 140×140 mm region of interest is cut around each knee so that the coordinate frame is the same across patients and acquisition centers. Each knee image is rotated so that the tibial plateau is horizontal. Intensities are clipped between the 5th and 99th percentiles, the image minimum is subtracted, and the result is divided by the maximum pixel value.
The images are converted to 8-bit depth, resized to 310×310 pixels at a pixel spacing of 0.45 mm, and left knees are flipped horizontally to match the right knee.
Logistic regression and GBM reference models
The logistic regression reference uses age, sex, BMI, KL grade, injury and surgery history, and the WOMAC score, and the authors chose model 2 over model 1 because it has higher precision at lower recall and similar performance elsewhere. Regularization made no difference in cross-validation on OAI data. Logistic regression cannot train on knees with missing values, so training knees with missing values were dropped and missing test-set variables were filled by mean value imputation.
The authors hypothesize that logistic regression cannot capture non-linear relationships among the clinical and image-assessment variables, so they train a GBM on the same inputs. The GBM is a LightGBM implementation, and its hyperparameters were tuned with hyperopt over 500 trials, each maximizing AP on cross-validation. Model 4, the GBM with all clinical variables and KL grade, performed best among the reference models, with AUC 0.76 (0.75-0.78) and AP 0.63 (0.61-0.65).
Multi-task CNN on the baseline radiograph
The network uses a pre-trained se-resnext50-32xd feature extractor, which the Methods call se-resnext50 32x4d, followed by Global Average Pooling and two fully connected heads. One head has three outputs for the progression classes and the other has five outputs for the baseline KL grade. The fine-grained progression classes are inaccurate on their own, but the authors found that predicting them helps regularize training and improves the overall progression probability P(y>0|x) derived from the CNN.
Convolutional weights start from ImageNet training, while the two fully connected heads start from random noise. A dropout layer with p = 0.5 sits before each fully connected layer. Training uses random noise addition, random rotation within ±5 degrees, random 300×300 crops from the 310×310 image and random gamma correction, aimed at invariance to acquisition differences.
Cross-validation produces five models, and for each split the weights kept are the snapshot with the highest AP on the validation set, while hyperparameters were chosen empirically.
Test-time augmentation and attention maps
Each cross-validation model predicts five 300×300 crops, four from the corners and one from the center, and the five predictions are averaged. The averaged predictions of all cross-validation models are then averaged again, which the authors say reduces the variance of the CNNs. When the CNN is used alone, its progression probability is the sum of the probabilities of the fast class and the slow class.
GradCAM was modified to work with test-time augmentation, and its attention map shows which image regions positively correlate with the network output. Because the averaging and the sum of progression probabilities are differentiable, GradCAM applies directly to the averaged output.
Fusing CNN outputs with clinical variables
The second-level GBM takes the CNN's KL-grade probabilities and progression probabilities together with age, sex, BMI, injury history, surgery history and WOMAC. The text gives the KL-grade probability index as 0 to 3 in one passage and as 0 to 4 in another, so the exact input set is not stated consistently. Model 6 leaves the KL grade out, while model 7 adds it, and the authors hypothesize that a radiologist and the network may grade differently, so the difference could be informative.
The five CNN models are applied to their validation folds, so each training knee gets a CNN prediction from a model that did not train on it, and the second-level GBM reuses the same cross-validation split. Stacking of this kind is prone to overfitting and needs a robust cross-validation scheme, which is why the authors use the matched splits.
Because a GBM accepts knees with missing values, the fused model uses them without imputation, unlike the logistic regression reference.
CNN against the reference models
The GBM with all clinical variables and KL grade reached AUC 0.76 (0.75-0.78), compared with 0.75 (0.74, 0.77) for logistic regression with the same variables.
The CNN alone, trained on the baseline radiograph, reached AUC 0.79 (0.77-0.80) and AP 0.68 (0.66-0.70) on the MOST test set. In cross-validation on the training set, the same CNN reached AUC 0.76 and AP 0.56.
The CNN uses only the knee image, whereas reference model 4 uses KL grade and clinical data.
Fused models with and without KL grade
Model 6, the CNN fused with age, sex, BMI, injury, surgery and WOMAC, reached AUC 0.79 (0.78-0.81) and AP 0.68 (0.66-0.71). Model 7, which also takes the KL grade, reached AUC 0.80 (0.79-0.82) and AP 0.70 (0.68-0.72).
Table 2 lists models 2, 4, 5, 6 and 7 on MOST with 95% confidence intervals, and the CNN alone is model 5 with AUC 0.79 (0.77-0.80) and AP 0.68 (0.66-0.70).
Knees with KL-0 or KL-1 at baseline
The authors evaluate a subgroup of MOST knees that are KL-0 or KL-1 at baseline, a group they treat as absence of osteoarthritis. In this subgroup, model 7 reached AUC 0.80 (0.78-0.82) and AP 0.62 (0.58-0.65), and the CNN alone reached AUC 0.78 (0.76-0.80) and AP 0.58 (0.55-0.61). Model 2 reached AUC 0.73 (0.70-0.75) and model 4 reached AUC 0.75 (0.72-0.77) in the same subgroup.
These subgroup values come from a smaller population than the full test set, so they are not a direct replacement for the overall results. The authors conclude from this that the method can flag progression in knees without radiographic OA at baseline.
What the attention maps show
GradCAM maps were computed for well-predicted knees and set against the follow-up images from MOST. In many cases the CNN attended to the compartment opposite the one where degenerative change later became visible, and tibial spines were highlighted in several maps. These spine associations do not hold for all progressors.
The authors caution that GradCAM gives no theoretical guarantee that the network has found causal links between image features and the output, so each map needs careful analysis.
Limitations
The model has been tested only on populations from the United States, so other populations remain untested. The model was built only on standardized radiographs taken with a positioning frame, so validation on images without the frame is still needed, although the test set includes several beam angles.
Progression was defined only by the KL grading system, so the symptomatic side of progression was not modelled. Mean value imputation in the MOST test set may have lowered the performance of the logistic regression references, while the GBM route used data without imputation. The authors state that, for subjects at risk, the proposed model identifies progressor cases about 6% more accurately than the methods previously used in the OA literature.
Paper info
- Authors
- Aleksei Tiulpin, Stefan Klein, Sita M. A. Bierma-Zeinstra, Jérôme Thevenot, Esa Rahtu, Joyce van Meurs, Edwin H. G. Oei, Simo Saarakkala
- Venue
- arXiv · Preprint
- First published
- 2019-4-12
- Added
- 2026-11-6
- Updated
- 2019-5-6
- Version
- v2
- arXiv
- 1904.06236
- Category
- cs.CV
- Original paper terms
- CC BY 4.0
- What we show
- Paper info, commentary and permitted figures from the original paper
AI commentary is a separate explanation from the original paper and may contain errors. The original paper and figures follow each source's terms of use and any rights noted separately.
Abstract
Knee osteoarthritis (OA) is the most common musculoskeletal disease without a cure, and current treatment options are limited to symptomatic relief. Prediction of OA progression is a very challenging and timely issue, and it could, if resolved, accelerate the disease modifying drug development and ultimately help to prevent millions of total joint replacement surgeries performed annually. Here, we present a multi-modal machine learning-based OA progression prediction model that utilizes raw radiographic data, clinical examination results and previous medical history of the patient. We validated this approach on an independent test set of 3,918 knee images from 2,129 subjects. Our method yielded area under the ROC curve (AUC) of 0.79 (0.78-0.81) and Average Precision (AP) of 0.68 (0.66-0.70). In contrast, a reference approach, based on logistic regression, yielded AUC of 0.75 (0.74-0.77) and AP of 0.62 (0.60-0.64). The proposed method could significantly improve the subject selection process for OA drug-development trials and help the development of personalized therapeutic plans.
Quote from the paper
Aleksei Tiulpin, Stefan Klein, Sita M. A. Bierma-Zeinstra, Jérôme Thevenot, Esa Rahtu, Joyce van Meurs, Edwin H. G. Oei, Simo Saarakkala (2019). Multimodal Machine Learning-based Knee Osteoarthritis Progression Prediction from Plain Radiographs and Clinical Data. arXiv:1904.06236v2. https://arxiv.org/abs/1904.06236v2
BibTeX
@misc{tiulpin2019multimodal,
title = {{Multimodal Machine Learning-based Knee Osteoarthritis Progression Prediction from Plain Radiographs and Clinical Data}},
author = {Aleksei Tiulpin and Stefan Klein and Sita M. A. Bierma-Zeinstra and Jérôme Thevenot and Esa Rahtu and Joyce van Meurs and Edwin H. G. Oei and Simo Saarakkala},
year = {2019},
eprint = {1904.06236},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/1904.06236v2}
}