PDO Drug Screening Data for Evaluating and Training AI Drug Response Prediction Models
Patient-derived organoid screens test whether cell line drug response models transfer
- Problem Drug response models learn mostly from cell line screens, which drift from patient tumors. Organoid data are closer to tumors but too scarce to build or check models.
- Method The authors run four organoid screens and retrain six existing models under three schemes. The schemes train on cell lines only, mix in organoid data, or fine-tune on organoids.
- Results Under random split, adding organoid data to training raised organoid R2 on IMPROVE dataset 1 from 0.25 to 0.72.

Figure 2 : Overview of the DRP analysis framework. Six DRP models were used to predict PDO drug response using three learning strategies: cell line-only training, joint cell line and PDO training, and transfer learning with pretraining on cell lines followed by fine-tuning on PDOs. Random splits performed 10-fold cross-validations, whereas cancer-blind splits usedN-fold data partitioning, where on IMPROVE datasets Nis the number of PDO lines in the dataset and on Pilot 1 datasetNis 10.
Original paper · CC BY 4.0 · Y. Zhu, K. Marlor, V. Lavelle, T. S. Brettin, M. Sacco, C. Siniscalchi, H. W. Raeder, M. R. Weil, R. L. Stevens · PDO Drug Screening Data for Evaluating and Training AI Drug Response Prediction Models · Original paper figure · Extracted the figure area from page 8 of the original PDF.Why cell line models miss organoid responses
Most drug response prediction models learn from screens run on immortalized cancer cell lines. Cell lines are cheap to culture, reproducible, and can proliferate indefinitely, which is why they supply most training data. The cost is that long culture in flat monolayers alters molecular traits and drops tumor architecture and microenvironment.
Patient-derived organoids are three-dimensional cultures grown from patient tumor tissue, so they keep more of the tumor's traits. They retain genomic, molecular, and phenotypic characteristics more faithfully than immortalized cell lines. Yet PDO pharmacogenomic data remain limited next to the large drug screening datasets available for cell lines.
Without enough organoid measurements, DRP models for these cultures can't be built or checked properly.
Three of these studies share overlapping PDOs and compounds, so the same drugs can be compared across platforms. They evaluated six publicly available DRP models under three learning strategies. The first strategy trains models on cell line data alone and applies them directly to organoid responses. The second strategy trains on cell line data mixed with part of the PDO data.
The third strategy pretrains on cell line data and then fine-tunes on a subset of PDO data. The open question is how far cell line knowledge carries over to organoids, and whether limited organoid data help.
Four organoid screens and what they measure
Three IMPROVE screens and one Pilot 1 screen make up the four organoid datasets in this paper. IMPROVE datasets 1, 2 and 3 include 4, 5 and 10 organoid lines respectively, while Pilot 1 has 47 organoid lines. The IMPROVE datasets share two common colorectal cell lines, which the authors kept as a benchmark. Pilot 1 covers 27 colorectal PDO lines and 20 head and neck cancer PDO lines that the IMPROVE sets don't contain.
The authors chose colorectal and head and neck cancer because their previous analysis showed lower response prediction accuracy for these types.

Table 1 : Summary of datasets and experimental sources. The final row reports the total number of unique experiments, drugs, cell lines, and organoids across all sources.
Original paper · CC BY 4.0IMPROVE dataset 1 used a 3D high-content imaging assay on two cell lines and four PDO models. Organoids were size-filtered to 20–70 µm and seeded at a density matched to the cell lines, and compounds were exposed for 5 days. Compounds were tested at seven concentrations, and the fraction of living cells was used to build the AUC over [100 pM, 100 µM].
IMPROVE dataset 2 screened seven colorectal models with 40 compounds, each at seven concentrations in three replicate wells. Viability came from the CellTiter-Glo 3D ATP-release assay, normalized to negative controls on the same plate. IMPROVE dataset 3 ran in two phases, with 100 compounds in the first organoid screen and four concentrations in the second.
The second phase added four colorectal PDO lines and one sarcoma PDO line, with cells treated twice on consecutive days. Each screen's viability values were turned into normalized AUC over [100 pM, 100 µM], so all responses share one target.
The authors ran RNA-seq on the organoid lines and used log2(TPM + 1) as gene expression values. Copy number, somatic mutation and DNA methylation for HCMI organoids came from the Genomic Data Commons. Pilot 1 organoids had somatic mutations and copy numbers measured with a targeted DNA-seq assay. Cell line omics and drug features came from the IMPROVE benchmark, with 512-bit Extended Connectivity Fingerprints generated by RDKit.
Three ways to use organoid data
The key move is to keep six existing DRP models fixed in design and vary only which data they train on. The three schemes are cell lines only, cell lines mixed with organoids, and cell lines followed by organoid fine-tuning. All six models take gene expression as the cancer input, paired with a drug representation that depends on the model.
The first scheme pools cell line data from CCLE, CTRPv2, GDSCv1, GDSCv2 and gCSI for training. The trained models are then applied to each organoid dataset with no adaptation, so the test is zero-shot. This scheme sets the baseline that the other two must beat, because no organoid molecular or response data enter training.
Joint training fits one model on the cell line train and validation sets plus the organoid train set. The organoid validation set steers hyper-parameter optimization and early stopping, so the organoid test set stays held out. Organoid data make up only a very small share of that training pool, which may limit their effect. Under the random split scheme, the 10 cell line partitions and 10 organoid partitions produced 100 models for each organoid dataset.
Transfer learning starts from each cell line pretrained model and keeps training it on the organoid train and validation sets. The updated model is then scored on the organoid test partition, while the cell line test set serves as a quality check. For GraphDRP, the authors freeze early layers and update late layers, so the trainable layer count becomes a hyper-parameter.
That layer count is searched with the differential evolution approach, and for LGBM the authors add boosting steps to the pretrained model.
Random and cancer-blind splits
Random split places each sample into training, validation, or test sets without regard to cancer case. Cancer-blind split keeps every cancer case inside a single set, so the test cases are unseen during training. The authors link random split to drug repurposing. They link cancer-blind splitting to precision oncology, which they describe as the more challenging task.
Cell line data use 10-fold partitioning at 8:1:1 in both schemes. For organoid data, random split keeps 10-fold partitioning at 8:1:1. Under cancer-blind split, organoid data use N-fold partitioning at N-2:1:1, where N is the number of organoid lines. Pilot 1 is the exception with 47 lines, so it keeps 10-fold at 8:1:1 under cancer-blind split.
Each prediction is scored with R2 and the Pearson correlation coefficient against the true normalized AUC. Organoid experiments and cell line experiments inside the PDO studies are scored separately. Under random split, the 10 CCL partitions and 10 PDO partitions give 100 joint-training models for each organoid dataset. Under cancer-blind split, joint training trains 10×N models for each IMPROVE dataset and 100 models for Pilot 1.
Transfer learning under random split produces 100 fine-tuned models for each organoid dataset.
Cancer-blind evaluation lowers the average CCL test R2 to 0.68, compared with 0.77 under random split. The authors read this drop as a sign that the cancer-blind task is harder, because the test cases are new. The organoid results change little between the two splits, because organoid lines never enter the CCL training data under either scheme.
Cell line-only models on organoids
Under random split, models trained only on cell lines reach a model-average R2 of 0.77 on their own test set. On organoids, the same models score 0.25 on IMPROVE dataset 1, -0.26 on IMPROVE dataset 2, 0.24 on IMPROVE dataset 3 and 0.07 on Pilot 1. The drop is large, and the authors tie it to two causes: the biological gap between cell lines and organoids, and differences in experimental protocols and assay technologies.
No organoid line enters training in this scheme, so the models face organoids as a zero-shot target.

Table 2 : Prediction performance (R 2, mean±s.d.) of models trained exclusively on CCL data in random split cross-validations. CCL Test indicates the test set of CCL data. Prediction performance on CCL exper- iments and PDO experiments in IMPROVE datasets 1-3 are listed separately.
Original paper · CC BY 4.0Performance differences across model architectures are wider on organoids than on the cell line test set. Model averages hide that spread, since individual models vary more on the organoid datasets. No single model is best on every organoid dataset, so the choice of architecture matters less than the data source.
The authors read the drop as a harder precision oncology task than the random-split repurposing task. Under cancer-blind splits, the model-average CCL test R2 falls to 0.68 from 0.77, which supports that reading. Organoid averages move little between the two splits, because organoid lines stay out of cell line training either way. They didn't test whether a better cell line model would close the organoid gap on its own.
Adding organoid data to training
Adding organoid data to training changes the picture a lot under random split. Random split places no restriction on shared cancer cases, while cancer-blind splits keep training, validation and test cases apart.
Joint training doesn't cost much on cell lines. The model-average CCL test R2 is 0.7575, close to the 0.77 reached with cell lines only. The authors read the gain as evidence that organoid data carry information the cell lines lack.
IMPROVE dataset 2 stays the weakest PDO dataset, with some negative R2 values. The authors trace this to insufficient mixing of the cell culture medium, which caused uneven seeding across wells. PCC sometimes stayed moderate to high even when R2 was negative, so the models could still rank drug responses.
These averages sit below the random-split values, which the authors take to mean unseen cancer cases are harder to predict. UNO has the highest or tied-highest organoid R2 on all four datasets under random split. Under cancer-blind splits, UNO leads on two of the four datasets.
Fine-tuning after cell line pretraining
Fine-tuning was run only for GraphDRP and LGBM, starting from models pretrained on cell line data. GraphDRP froze its early layers and updated only its late layers on PDO data. The number of trainable layers was tuned as a hyper-parameter with differential evolution. LGBM instead continued training by adding boosting steps to its pretrained model.
Each of the 10 models pretrained on the CCL cross-validation partitions was updated on a PDO partition, giving 100 fine-tuned models per PDO dataset under random split.
Under random split, fine-tuning raised PDO R2 above joint training for both models on all four PDO datasets, by 0.03 to 0.11. The authors attribute this to organoid lines forming a tiny share of the joint training set. Under cancer-blind splits, GraphDRP gained on three of the four organoid datasets, by 0.01 to 0.07. Under the same splits, LGBM gained on all four organoid datasets, by 0.02 to 0.18.
Cancer-blind runs trained 10×N fine-tuned models for the IMPROVE datasets and 100 for Pilot 1.
The cost appears on cell lines, where CCL test R2 drops for both models after fine-tuning compared with joint training. The authors call this forgetting previously learned cell line response patterns. On the IMPROVE cell line experiments, GraphDRP improved on all three studies under random split, and LGBM improved on two. Cancer-blind results show the same trade-off between cell line and organoid performance.
Agreement between the IMPROVE screens
The three IMPROVE screens share many experiments, so the authors compared normalized AUC values pair by pair. Each point in these comparisons is one experiment measured in both studies, and the Pearson correlation coefficient (PCC) summarizes the agreement. Datasets 1 and 3 show the strongest agreement, with a PCC of 0.645 over 594 common experiments.
Datasets 1 and 2 follow with a PCC of 0.547 over 240 common experiments. Datasets 2 and 3 show the weakest agreement, with a PCC of 0.371 over 280 common experiments.

Figure 3 : Pairwise comparison of drug response measurements across the three IMPROVE studies. Scatter- plots show the normalized AUC values of matched experiments between a pair of IMPROVE datasets. Each point represents an experiment measured in both studies. PCC and the number of matched experiments are reported for each comparison.
Original paper · CC BY 4.0The authors call all three correlations moderate, so differences in protocols and assay technologies leave a lot of spread in the measurements. They argue that the reproducibility of drug screening measurements needs to improve. They also suggest that future PDO resources should treat experimental standardization, quality control, and study or site effects as part of benchmark design.
A model trained on one screen can't easily carry over to a screen that measures responses differently, which the authors see as a reason to keep such heterogeneous data.
IMPROVE dataset 2 gave the weakest organoid results, so the authors looked at how it was produced. They found that insufficient mixing of the cell culture medium caused uneven seeding across wells and added substantial noise. Even when R2 was low or negative, the PCC sometimes stayed moderate to high. That pattern suggests the models captured the relative ranking of responses better than their magnitudes.
Limitations of the PDO drug response study
The study's limits start with the features used: only gene expression represented the cancer models in the DRP analyses. The authors also generated copy number, somatic mutation, and DNA methylation data, but those layers didn't enter the models. Transfer learning was run for only two models, GraphDRP and LGBM, so the other four architectures never got that treatment.
That means the fine-tuning gains can't be assumed to hold across the full model set.
Forgetting is another open issue, since fine-tuning lowered CCL test performance for both models. The authors propose source replay as a fix, mixing a small sample of CCL data into fine-tuning. They didn't run source replay, so its effect on forgetting remains untested.
The organoid sets are small, with 4, 5 and 10 lines in the IMPROVE studies. Pilot 1 adds 47 lines, which still limits how far the PDO results generalize. The authors also say that substantially larger and more diverse datasets are needed for accurate, generalizable models.
Predicting patient responses was not tested, since the authors place that bridge in future work. Patient-level data would need multi-domain transfer learning, which this study doesn't attempt. The IMPROVE dataset 2 result is attributed mainly to uneven seeding from poor medium mixing, which is a reported cause, not a tested fix. Moderate correlations between the IMPROVE screens, from 0.371 to 0.645, also cap how much any model can reach.
Paper info
- Authors
- Y. Zhu, K. Marlor, V. Lavelle, T. S. Brettin, M. Sacco, C. Siniscalchi, H. W. Raeder, M. R. Weil, R. L. Stevens
- Venue
- arXiv · Preprint
- First published
- 2026-11-11
- Added
- 2026-11-13
- Updated
- 2026-11-11
- Version
- v1
- arXiv
- 2611.15769
- Category
- q-bio.QM · cs.AI
- Original paper terms
- CC BY 4.0
- What we show
- Paper info, commentary and permitted figures from the original paper
AI commentary is a separate explanation from the original paper and may contain errors. The original paper and figures follow each source's terms of use and any rights noted separately.
Abstract
Anti-cancer drug response prediction (DRP) is critically important for precision oncology and therapeutic development. Currently, most DRP models are developed using drug screening data from immortalized cancer cell lines, which can differ substantially from patient tumors at the genomic and molecular levels, even though patient tumor response is the ultimate prediction target. To help bridge this gap and bring DRP models closer to their intended clinical application, we conducted four drug screening studies using patient-derived organoids (PDOs), which more faithfully recapitulate patient tumors than immortalized cell lines. These studies generated data for improving and evaluating DRP models, including multi-omics profiles of PDO lines, drug feature data, and treatment response measurements. Using these data, we retrained and evaluated multiple publicly available DRP models under three model-building scenarios: training models using cell line data only, training models using combined cell line and PDO data, and pretraining models on cell line data followed by fine-tuning on PDO data. We then evaluated and compared model prediction performance on PDOs across these analysis scenarios. In addition, we also assessed the consistency of drug screening viability data generated by different laboratories using different assay technologies and/or experimental protocols.
Quote from the paper
Y. Zhu, K. Marlor, V. Lavelle, T. S. Brettin, M. Sacco, C. Siniscalchi, H. W. Raeder, M. R. Weil, R. L. Stevens (2026). PDO Drug Screening Data for Evaluating and Training AI Drug Response Prediction Models. arXiv:2611.15769v1. https://arxiv.org/abs/2611.15769v1
BibTeX
@misc{zhu2026drug,
title = {{PDO Drug Screening Data for Evaluating and Training AI Drug Response Prediction Models}},
author = {Y. Zhu and K. Marlor and V. Lavelle and T. S. Brettin and M. Sacco and C. Siniscalchi and H. W. Raeder and M. R. Weil and R. L. Stevens},
year = {2026},
eprint = {2611.15769},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2611.15769v1}
}