Profile

Settings

Loading…

← Papers

Help

FAQ

Which features require signing in?

You can read the commentary, paper info, Model Structure and related papers of public papers without signing in. Sign in to manage your account or contact us about your inquiries.

Can I upload a PDF file?

Upload papers with an arXiv or DOI link; the commentary is public to everyone. Papers whose source and terms of use can't be verified, so the commentary can't be made public, can't be uploaded. Uploading PDF files and keeping papers private are for subscribers only, and a paper uploaded as a file is saved as private only. Searching for official info by title runs only when you press the button.

Are the figures and AI commentary accurate?

Figures come only from the original paper, and only those whose terms of use are verified are shown. The commentary is written by AI and may be wrong. Check important claims, numbers and figure context against the evidence in the original paper.

I want to report a copyright issue.

Terms of use and the source of the original paper are on the Paper info tab. If there's a problem, choose "Paper content, figures and copyright" under Contact us and send the paper link, the part in question, and evidence that you hold the rights. Receiving your report doesn't confirm any rights or remove anything right away. You can see the result of the review under My inquiries.

I forgot my password.

If you signed up with email, use Forgot password in the sign-in window to reset it with your verified email. If you signed up with Google, Naver or Kakao, change your password with that service.

What should I include in an inquiry?

Tell us which screen you were on and what you were doing when the problem happened, along with the paper link. Don't include personal information such as passwords, API keys, verification codes or phone numbers. Inquiries and replies are stored in Refivu and you can see them under My inquiries.

How do I delete my account?

In Settings, under My account, press Delete account. Review what will be deleted and complete identity verification to delete your account. For other requests, choose "Account" under Contact us.

Paper commentary

A 3D Probabilistic Deep Learning System for Detection and Diagnosis of Lung Cancer Using Low-Dose CT Scans

The detector and diagnosis model can be tuned together for lung cancer

  • Problem Lung CT systems usually tune nodule detection or diagnosis alone, so their coupling goes unexamined. The detector's output feeds the diagnosis stage, so tuning one alone can miss how they interact.
  • Method The authors build a 3D CNN cascade that tunes the nodule detector and diagnosis model together, and add model uncertainty to the output probabilities.
  • Results The CADx model reached 0.87 AUC on Kaggle Stage-2, compared with 0.84 for a prior NLST-trained system.

Why detection and diagnosis get tuned apart

Low-dose CT screening produces more scans than radiologists can comfortably read, which is why automated tools are attractive. Most published work, though, tunes either nodule detection (CADe) or diagnosis (CADx) on its own. That matters because the detector's output is the diagnosis stage's input, since CADx ranks and classifies whatever candidates CADe passes on.

The authors found that a CADe model tuned for the LUNA16 benchmark can be well short of optimal for cancer diagnosis.

The coupling runs in both directions: a CADe model tuned for high precision can miss malignant nodules. A CADe model tuned for high recall, by contrast, sends excess false positive candidates to a CADx system. The authors also found that their CADx component stays robust at a maximum CADe false-positive rate of approximately 8 candidates per patient.

Given that robustness, they don't treat CADe false positive reduction as a required step in their pipeline.

A second gap is uncertainty, because automated tools often can't say how confident they are. A probability that reports its own uncertainty helps doctors act on the output, since it can flag scans the model is unsure about. The authors therefore set out to build the detector and the diagnosis model as one system that reports calibrated probabilities.

One cascade, tuned as a whole

The key idea is to treat the CADe detector and the CADx diagnosis model as one cascade and tune them together. Each module's quality shows up in the final patient-level score, so the detector is judged by its effect on diagnosis as well as by its own benchmark. Because the diagnosis step depends on the nodule candidates it receives, the authors develop both modules at once.

CADx performs nodule-level assessment and patient-level malignancy classification by analyzing suspicious lesions from CADe. The authors argue that a CADe system tuned for high recall or high precision will change how well CADx works downstream.

A full 3D scan is first preprocessed into a fixed format before any detection happens. The preprocessed scan then goes into the CADe module, which performs 3D segmentation to find lung nodules with the highest possible recall. CADe labels every voxel with a nodule probability, and a thresholded, opened and labeled segmentation yields the candidates.

Figure 1: Our overall CAD system diagram. Since CADx performance is so
reliant on the quality of the nodule candidates generated by the CADe, both
were develop…

Fig. 1 . Our overall CAD system diagram. Since CADx performance is so reliant on the quality of the nodule candidates generated by the CADe, both were developed simultaneously to achieve the best overall performance.

Original paper · CC BY 4.0 · Onur Ozdemir, Rebecca L. Russell, Andrew A. Berlin · A 3D Probabilistic Deep Learning System for Detection and Diagnosis of Lung Cancer Using Low-Dose CT Scans · Original paper figure · Extracted the figure area from page 3 of the original PDF.

The CADe output is a list of identified nodules that feeds the CADx module. CADx uses two cascaded 3D deep learning models, where the first model ranks candidates by malignancy risk. The system outputs a per-patient malignancy probability, per-nodule malignancy scores, and segmented nodule candidates.

The paper's own data pipeline begins with the LIDC-IDRI dataset, used for both CADe and CADx components. Kaggle data is the separate source for the CADx training and test stages. The authors make the cascade's interaction measurable by evaluating CADx on candidates from different CADe thresholds.

Datasets and preprocessing

The CADe and CADx modules both draw on LIDC-IDRI, through the curated version that the LUNA16 challenge provides. That version includes 888 patients and consensus labels, with 1186 annotated nodules in total. The consensus labels come from agreement of 3 of 4 radiologist annotators, and each nodule keeps the malignancy scores its annotators gave.

LIDC-IDRI doesn't include very large nodules or masses, which limits its use for full patient diagnosis in a standalone CADe system.

The CADx classifier trains on the Kaggle Stage-1 set, which has 1595 patients, with 419 (∼26%) diagnosed with lung cancer within one year. The Kaggle Stage-2 set, with 506 patients and 153 (∼30%) diagnosed, serves as the test set. Stage-2 is more recent and has thinner slices, so it tests whether the CADx system generalizes beyond its training data.

Preprocessing only clips each scan to between -1000 and 400 Hounsfield units, which removes most of the bone variation. The pipeline then resamples each scan so voxels measure 1 mm in each dimension. Before the neural networks see a scan, its voxels are normalized to a mean of 0 and a variance of 1. The affine augmentation uses uniformly sampled 3D rotations and reflections, plus small random scaling and translations in all three dimensions.

Gamma changes, Gaussian blur or unsharp masking, and additive Gaussian noise add further variation during training. The augmentations reduce overfitting and help transfer learning across scans taken with different setups, and they're switched off at test time.

How the CADe segmentation network produces nodule candidates

The CADe segmentation network is a 3D fully convolutional network that Ozdemir et al. adapted from V-Net. It stacks three encoder-decoder block pairs with skip connections, plus input and output blocks. Each encoder block applies a 2× downsampling convolution, two kernel-size-3 convolutions, and a residual connection. Instance normalization replaces batch normalization in every block, and ReLU provides the nonlinearity.

The authors take nodule centres and diameters from the LUNA16 annotations and turn them into spherical voxel masks. Nodule voxels are a tiny share of each scan, and a whole CT scan is too large to train on directly. The sampler draws 643-shaped blocks near a known nodule with probability 1 minus 0.7 to the power N, and otherwise samples at random.

The loss is cross entropy that weights nodule voxels twice as much as background, and each patient scan is seen once per epoch.

Figure 3: Sample nodule segmentations from our CADe segmentation model,
sliced through the center of each nodule candidate. First row: Input CT
scan images fro…

Fig. 3 . Sample nodule segmentations from our CADe segmentation model, sliced through the center of each nodule candidate. First row: Input CT scan images from LIDC-IDRI test data. Second row: Our corresponding segmentation probabilities. Third row: (Spherical) voxelwise labels extracted from the LUNA16 annotations.

Original paper · CC BY 4.0

When the block outputs are stitched, edge voxels are weighted by how much of their field of view lies inside each input block. The authors report that this matches a single full-scan pass on a CPU while needing an order of magnitude less time. The network thresholds the voxel scores, applies a nearest-neighbors binary opening filter, and labels regions with voxel connectivity of one.

A separate candidate scoring network reruns on 323-shaped blocks centred on each candidate, and it serves only the LUNA16 evaluation. The scoring network trains with SGD at learning rate 0.01 and momentum 0.9, decaying the rate by 0.8 every 100 epochs. Its outputs carry Monte Carlo dropout uncertainty, which the authors use to make the nodule probabilities well-calibrated.

How CADx turns candidates into a patient probability

The malignancy ranking network reuses the layout of the CADe candidate scoring network and regresses a label built from LIDC-IDRI radiologist scores. Each radiologist gives an integer malignancy score from 1 to 5, so each nodule carries between one and four scores. Because these scores were not confirmed by follow-up biopsies and were not consistent between radiologists, the authors treat them as noisy labels for ranking rather than as diagnoses.

Sampling starts with nodules that have at least three scores for the first 50 epochs, then draws 90% from those and 10% from the remaining score-1 set. This curriculum keeps the network from biasing toward benign scores, since most detected candidates are benign.

The malignancy classification network is an attention-based multiple instance learning model that processes the top-k ranked candidates. A tanh layer maps each feature vector to xi, and a softmax over the candidates gives attention weights y that lie in [0, 1] and sum to one. The weights average the feature vectors, and a sigmoid of w3 transpose H y gives the patient malignancy probability p.

Because the weights are a function of the features, the model is permutation-invariant over candidates. Leaky NOR and LSE also added hyperparameters, which made them harder to optimize.

The classifier trains on the Kaggle Stage-1 patients combined with a subset of LUNA16 patients, and Stage-2 is held out as the test set. LUNA16 patients with a nodule scored by at least three radiologists and an average score of 4 or higher count as malignant, while patients with no annotations or with all nodules averaging 2 or lower count as benign.

This procedure added 556 patients, of whom 169 (about 30%) were malignant, for 2101 training patients in total. Because LUNA16 annotators were told to ignore nodules larger than 30 mm, the authors pass two candidate sets to the classifier: one from the original 1 mm scans and one from 2 mm downsampled scans. The top-k candidates from each ranked list are selected, with k treated as a hyperparameter, and the best model uses top-2 from each list, four candidates in all.

The classifier trains with SGD at momentum 0.9 and an initial learning rate of 0.01, halved every 50 epochs. It uses binary cross entropy and batches of 32 scans for 750 epochs. Figure 5 shows example patients with the attention weight of each candidate printed above it and the patient probability below.

Where the uncertainty comes from

The authors estimate model uncertainty with Monte Carlo (MC) dropout, which keeps dropout active at test time and samples repeated predictions. For the candidate scoring network, the authors trained 10 models, each holding out one of the 10 LUNA16 subsets as its test set. This lets the authors approximate Bayesian inference by sampling over the features, so repeated passes give a spread of outputs.

The resulting probabilities cover uncertainty in the model weights and the uncertainty inherent to the data, including label noise. Without dropout at test time, the same network's probabilities tend to be overconfident, as Figure 9 shows.

The CADx classifier uses a different combination: MC dropout together with a deep ensemble of five models. Each of the five models is trained on a different train and development split. Ensembling trains a model several times from randomly initialized parameters and averages the results. The authors use these predictions, obtained with MC dropout, both to assess uncertainty and to boost performance.

With only one test set, the authors found the ensemble method combined with MC dropout more effective for estimating uncertainty. They cite prior work showing that this combination sometimes gives more reliable uncertainties than MC dropout alone.

Figure 10 compares the Bayesian ensemble with the best non-Bayesian CADx model. The best single network didn't systematically overestimate uncertainty, yet the ensemble stayed more stably calibrated across the full probability range.

LUNA16 results for CADe: does the scoring network cut false positives without losing nodules?

For each test split, one split served as validation to choose the segmentation and scoring model checkpoints, while the other eight trained both models. Candidate selection alone, at a segmentation threshold of 0.2 and with no false positive reduction, reached a sensitivity of 96.5% with 19.7 false positives per scan. The scoring network then cut false positives sharply, and it kept nodule sensitivity extremely high.

The averaged LUNA16 score of the scoring network is 0.921, which the authors report as the best published result on this dataset. The authors compare this with the 0.897 that a single-step 3D dense CNN reached, and that model needs no second false positive reduction step. Sensitivity is strongest for nodules with a diameter above 5 mm, because false positives are dominated by small candidates that are hard to tell apart from small true nodules.

Figure 6: The free response operating characteristic (FROC) for our CADe
candidate generation and scoring system on the LUNA16 dataset, with
patient-bootstrapp…

Fig. 6 . The free response operating characteristic (FROC) for our CADe candidate generation and scoring system on the LUNA16 dataset, with patient-bootstrapped 95% confidence interval, and the same results with our comparison model architecture (3D U-Net.)

Original paper · CC BY 4.0

The authors also ran the full pipeline with a standard 3D U-Net, tuning its feature count on LUNA16 validation performance. That comparison architecture reached an averaged LUNA16 score of 0.920, close to the 0.921 of the primary V-Net pipeline. The CADe and CADx results with the comparison architecture were similar to the primary results, as Figure 6 and Table I show.

The authors read this as evidence that the sampling and data-augmentation techniques drive the success of CADe more than the architectural details.

Kaggle Stage-2 results and the CADe operating point

The CADx model, trained on the top four ranked candidates per patient, reached an average AUC of 0.87 on Kaggle Stage-2. The authors chose that setting because it performed best on their development set, which kept the Stage-2 patients held out. The winning Kaggle solution in [5] also reached 0.87 AUROC, and the authors matched it. Unlike that solution, the authors didn't hand-label nodules in the Stage-1 data or ensemble several CADx models.

Figure 8: The receiver operating characteristic (ROC) curve for our CADx
system on the Kaggle Stage-2 test set, trained on both LUNA16 and Kaggle
Stage-1 data,…

Fig. 8 . The receiver operating characteristic (ROC) curve for our CADx system on the Kaggle Stage-2 test set, trained on both LUNA16 and Kaggle Stage-1 data, with patient-bootstrapped 95% confidence interval.

Original paper · CC BY 4.0

The authors then varied the CADe operating point from 1/8 to 8 false positives per patient. Across the operating points in Table I, primary-architecture CADx AUROC stayed between 0.863 and 0.869. CADx barely moved as the false positive rate changed, so extra CADe false positive reduction added no value. The main CADx candidates came from a CADe segmentation threshold of 0.5, which gave about 8 false positives per scan.

The comparison 3D U-Net produced CADx AUROC values from 0.858 to 0.869 across the same operating points.

The coupling test retrained CADx on candidates filtered at 1/8, 1 and 8 false positives per patient. Each retrained model was then tested on the same three settings. A model trained at 1/8 and tested at 8 scored 0.753 AUROC, compared to 0.869 when trained and tested at 8. The authors found that AUROC degraded significantly, and these models were less robust to false positives.

They read this as false positives in training improving the CADx model's own robustness to them.

Do the probabilities match outcomes

Calibration checks whether a predicted probability matches how often the outcome actually occurs in test data. The CADe candidate scoring networks were trained as 10 models, each holding out one of the 10 LUNA16 data subsets as its test set. Monte Carlo dropout keeps dropout active at test time, so the scores reflect uncertainty in the network weights as well as label noise.

On LUNA16 test data, these MC dropout probabilities are well-calibrated, as Figure 9 shows. Without dropout at test time, the same scoring network's probabilities tend to be overconfident in their predictions. The authors expect a larger gap under domain shift, such as unusual hardware, procedures or patients, but they didn't test that case.

For the malignancy classification network, the authors trained five models on five different train and development splits. They averaged the predictions of these models, each obtained by MC dropout, to build the ensemble estimate. Because only one test set was available, they combined the ensemble method with MC dropout instead of relying on one approach.

Figure 10 compares the Bayesian ensemble with the best non-Bayesian CADx model on calibration curves. The best single network didn't systematically overestimate uncertainty the way the CADe scoring network did, while the ensemble stayed more stably calibrated across the full range of probabilities.

Referral by entropy

The referral rule scores each probability by its binary entropy and refers the highest-entropy items to a radiologist. For CADe nodules, the authors plot the PR AUC of the scoring network against the percentage of nodules ignored. Entropy referral was compared with a random referral strategy, which the authors use as the baseline. The PR AUC improved dramatically, and the gain held even at a referral rate below 10%.

Performance on the remaining nodules approaches 1 as the referral rate increases.

Figure 11: The CADe scoring area under the precision-recall curve as a function
of referral percentage, for the entropy referral strategy and a random strategy…

Fig. 11 . The CADe scoring area under the precision-recall curve as a function of referral percentage, for the entropy referral strategy and a random strategy (with 95% confidence interval).

Original paper · CC BY 4.0

The authors read this as evidence that the nodule scoring probabilities stay well calibrated even close to 0 and 1. They argue that a perfect radiologist reviewing a subset of candidates could nearly remove false positive nodules. That claim assumes the referred candidates are reviewed correctly and no true nodules are lost. For patients, referral was measured as the ROC AUC on the remaining Kaggle Stage-2 data against the referral rate.

Referral lifted the CADx ROC AUC to a maximum of 0.885 on the remaining patients. The authors say model uncertainty combined with data uncertainty flags patients the network is more likely to misclassify.

Figure 12: The CADx area under the ROC curve as a function of referral
percentage, for entropy referral strategy and a random strategy with 95%
confidence inter…

Fig. 12 . The CADx area under the ROC curve as a function of referral percentage, for entropy referral strategy and a random strategy with 95% confidence interval. Note that the confidence interval is wider than the CADe scoring network because the number of patients in the Kaggle test set is smaller than the number of nodules in the LUNA16 dataset.

Original paper · CC BY 4.0

The AUC decreases at higher referral rates, so some decisions stay wrong even when CADx is confident. The histogram of CADx malignancy scores shows malignant patients clustering near 0. The authors tie this cluster to patients where CADe found no visibly malignant nodule. They list three causes: the nodule does not exist, it is too large for LUNA16-trained CADe, or it is missed.

The authors call this an unavoidable weakness of probability estimates from systems that rely on imperfect systems.

The conclusions tie the referral result to the broader claim that calibrated probabilities support patient referral decisions.

Limitations of the datasets and the CADe-CADx chain

LUNA16's annotators were told to skip nodules larger than 30 mm, so a CADe model trained on LUNA16 can learn to ignore large nodules. The LIDC-IDRI annotations also omit very large nodules and masses, which matter for full patient diagnosis. Aggressive zooming augmentation doesn't fully fix this, so the authors added a second candidate set from downsampled 2 mm scans.

The authors say CADx can't classify a malignant lesion that CADe misses, which they identify as the biggest source of false negatives. The histogram shows a mode near 0 for malignant patients, which the authors tie to missed nodules by the CADe model.

Figure 13: Histogram of CADx malignancy probability estimates for benign
and malignant patients. Note that the mode around 0 for malignant patients is
the reas…

Fig. 13 . Histogram of CADx malignancy probability estimates for benign and malignant patients. Note that the mode around 0 for malignant patients is the reason behind false negatives due to missed nodules by the CADe model.

Original paper · CC BY 4.0

The authors also say the decline in AUC at higher referral rates comes from patients whom CADe never flagged as a visibly malignant nodule. Such patients are either without a malignant nodule, have one too large for LUNA16-trained CADe, or have one that is simply missed. The malignancy ranking labels are noisy, because the radiologist scores were not confirmed by follow-up biopsies.

The radiologist scores also weren't consistent between different radiologists, so the labels stay subjective. The Kaggle Stage-2 test set holds 506 patients, so its confidence interval is wider than the CADe nodule-level interval. Training with referral in the loop, and a reject option, is left as future work by the authors.

Paper info

Authors
Onur Ozdemir, Rebecca L. Russell, Andrew A. Berlin
Venue
arXiv · Preprint
First published
2019-2-8
Added
2026-11-6
Updated
2020-1-21
Version
v3
arXiv
1902.03233
Category
cs.CV · cs.LG
Original paper terms
CC BY 4.0
What we show
Paper info, commentary and permitted figures from the original paper

AI commentary is a separate explanation from the original paper and may contain errors. The original paper and figures follow each source's terms of use and any rights noted separately.

Abstract

We introduce a new computer aided detection and diagnosis system for lung cancer screening with low-dose CT scans that produces meaningful probability assessments. Our system is based entirely on 3D convolutional neural networks and achieves state-of-the-art performance for both lung nodule detection and malignancy classification tasks on the publicly available LUNA16 and Kaggle Data Science Bowl challenges. While nodule detection systems are typically designed and optimized on their own, we find that it is important to consider the coupling between detection and diagnosis components. Exploiting this coupling allows us to develop an end-to-end system that has higher and more robust performance and eliminates the need for a nodule detection false positive reduction stage. Furthermore, we characterize model uncertainty in our deep learning systems, a first for lung CT analysis, and show that we can use this to provide well-calibrated classification probabilities for both nodule detection and patient malignancy diagnosis. These calibrated probabilities informed by model uncertainty can be used for subsequent risk-based decision making towards diagnostic interventions or disease treatments, as we demonstrate using a probability-based patient referral strategy to further improve our results.

Quote from the paper

Onur Ozdemir, Rebecca L. Russell, Andrew A. Berlin (2019). A 3D Probabilistic Deep Learning System for Detection and Diagnosis of Lung Cancer Using Low-Dose CT Scans. arXiv:1902.03233v3. https://arxiv.org/abs/1902.03233v3

BibTeX
@misc{ozdemir2019probabilistic,
  title = {{A 3D Probabilistic Deep Learning System for Detection and Diagnosis of Lung Cancer Using Low-Dose CT Scans}},
  author = {Onur Ozdemir and Rebecca L. Russell and Andrew A. Berlin},
  year = {2019},
  eprint = {1902.03233},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/1902.03233v3}
}

See related papersBrowse other papers

Paper preview
Account security

Connect Google account

If you connect a Google account, you can sign in with it too.

Refivu

Delete account

Refivu
Refivu

Sign up