- Problem Aggressive Cartesian undersampling of cardiac cine MR leaves aliased images, and compressed sensing and dictionary learning reconstructions lose anatomical detail at high rates.
- Method Stacks CNN reconstruction modules, each followed by a data consistency layer whose weight λ is set from the noise level, and trains the whole cascade end-to-end. For dynamic sequences it adds data-shared neighbouring-frame images as extra input channels.

Fig. 4 . A cascade of CNNs. DC denotes the data consistency layer and DS denotes the data sharing layer. The number of convolution layers within each network and the depth of cascade is denoted by nd and nc respectively. Note also that DS layer only applies when the input is a sequence of images.
Original paper · CC BY 4.0 · Jo Schlemper, Jose Caballero, Joseph V. Hajnal, Anthony Price, Daniel Rueckert · A Deep Cascade of Convolutional Neural Networks for Dynamic MR Image Reconstruction · Original paper figure · Extracted the figure area from page 6 of the original PDF.Why aggressive undersampling is hard
Undersampling k-space shortens acquisition, but it violates the Nyquist-Shannon condition, so the zero-filled image carries aliasing artefacts. Compressed sensing recovers such images by assuming sparsity in a transform domain and incoherence between the sampling pattern and that domain, and dictionary learning replaces the fixed transform with a sparse representation learned from the data.
Dynamic methods add temporal redundancy as a further prior, and the dynamic baselines in this study use a temporal gradient, low-rank structure or sparsity in the temporal Fourier domain.
Existing CNN work on MR reconstruction is preliminary, so its applicability to different imaging protocols has not been explored in depth. A single CNN applied once can overfit unless training data are very large, and training such a network can be slow and needs careful fine-tuning, which motivates an iterative use of CNNs. The study treats reconstruction as de-aliasing in the image domain, for 2D frames reconstructed independently and for dynamic sequences of 2D cardiac cine frames with Cartesian undersampling.
Forward model and the DC layer
Measured k-space samples y relate to the image sequence x through an undersampled Fourier encoding F_u plus additive white Gaussian noise e. In the Cartesian case F_u is the mask M applied after a 2D DFT of each frame, and the zero-filled reconstruction x_u = F_u^H y gives aliased images, because the system has fewer measurements than unknowns.
Earlier dictionary learning approaches enforce data fidelity through a formulation in which the regulariser is a patch-wise sparse code, and this study replaces the sparse code with a CNN, so that the objective becomes a squared distance from the CNN output plus λ times the squared data residual.
For large λ the sampled coefficients are replaced by the measured values, and λ is tied to the noise through \(\lambda=q/\sigma\), where q is a hyperparameter and σ² is the noise power in k-space.
To make this step a network layer, its forward pass is a Fourier transform, the k-space update and an inverse Fourier transform. Its input Jacobian is \(F^H\Lambda F\), where Λ is diagonal with entries 1 at unsampled positions and 1/(1+λ) at sampled positions, which keeps the backward rule simple. Because MR images are complex, the network uses real and imaginary channels, which doubles the real dimension, and the authors state that the derivation still holds under this representation.
When λ is trainable, its gradient is zero at unsampled positions and equals \((s_0(j)-s_{cnn}(j))/(1+\lambda)^2\) at sampled positions, so the weight is updated during training from the backpropagated error.
Stacking CNN modules with data consistency
Each CNN module is a stack of nd − 1 3D convolution layers, each followed by ReLU, with kernel size 3 and 64 filters, and a final convolution with kernel size 3 and 2 filters returns the two real-valued channels. A residual connection adds the module input to its output.
A DC layer follows each CNN module, and this pair is repeated nc times, so each later module refines the output of the one before it. The authors describe the cascade as an unfolding of the DLMRI optimisation, with one difference: the DC layers let the whole pipeline be trained jointly from the loss.
With nd and nc denoting depth and cascade count, a D5-C10 network has five convolution layers per module and ten cascade iterations, and the suffix (S) marks the variant that uses data sharing.
Using neighbouring frames as extra input
For frame t, the missing k-space entries are filled from frames t − nadj to t + nadj, and where several frames sample the same location their values are averaged.
The reduction in apparent acceleration is smaller than a simple count suggests: if each frame samples 10% of k-space, five adjacent frames would cover 50% in theory, but variable density sampling overlaps the low-frequency lines. Data-shared images are inconsistent with the dynamic content around the heart, so the authors feed them as extra inputs rather than as final reconstructions.
From the second subnetwork onward, the input is the previous estimate rather than an undersampled image, so the adjacent-frame samples are averaged with equal weight and the samples that were not acquired are updated.
Data, augmentation and optimisation
The dataset has 10 fully sampled short-axis cardiac cine scans, each with a single SSFP slice and 30 temporal frames. Multi-coil data were reconstructed with SENSE and then treated as single-coil data, and undersampling was simulated retrospectively from these images.
Frequency-encoding lines are fully sampled, and phase-encoding lines are drawn at random from a variable density Gaussian, with the eight lowest frequencies always acquired. Masks were generated on the fly during training, so the network sees new masks at a fixed acceleration rate.
The dataset of about 300 images is small, so augmentation uses translation of up to ±20 pixels along x and y, rotation over [0, 2π) and reflection along x with probability 50%. Dynamic training adds elastic deformation with α in [0, 3] and σ in [0.05, 0.1], sampled uniformly, and reflection along the temporal axis.
2D reconstruction against DLMRI
DLMRI used patch size 6×6 and 400 iterations per subject, and a joint dictionary was trained for all frames of a subject.
For 6-fold, the 6-fold CNN was initialised from the 3-fold trained weights. The authors report that DLMRI produced block-like artefacts from over-smoothing, while the CNN kept more texture and recovered some anatomical details that DLMRI did not.
A trained CNN reconstructs one slice in 23±0.1 milliseconds on a GeForce GTX 1080, whereas DLMRI took 6.1±1.3 hours per subject on CPU. The authors had no GPU implementation of DLMRI and expect it to take longer than 23 ms, since it needs dozens of dictionary learning and sparse coding iterations.
Depth trade-off and cascade count
D5-C2 had lower train and test errors than D11-C1, and its train-test gap was tighter.
The authors attribute the better generalisation of D5-C2 to its two DC steps, which rebuild the representation at each cascade iteration.
Test error fell at every step, and the rate of improvement was reduced after nc = 3. The authors note that a greedy start may trap the network in a suboptimal local minimum, and that random initialisation may give better results.
In the D5-C5 subnetwork outputs, the reconstruction gradually sharpens, but the fourth subnetwork output is grainier than the third. The authors read this as the later modules correcting over-smoothing from the earlier ones, which they attribute to end-to-end training.
Dynamic results against DLTG, kt-SLR and L+S
Three-way cross-validation over the 10 subjects was used, with the test errors aggregated.
At 9-fold undersampling, D5-C10(S) had smaller train and test error than D6-C10, which has no data sharing, and it also learned faster.
Across 3, 6, 9 and 11-fold, the CNN had lower reconstruction error than DLTG, kt-SLR and L+S. At 3-fold all methods performed approximately the same, and the gap widened at more aggressive rates, where kt-SLR and L+S degraded faster.
The authors attribute the weaker kt-SLR and L+S results to the data not being exactly low-rank and to their sparsifying transforms, a temporal FFT for L+S and a temporal gradient for kt-SLR, adapting less well than the learned models.
At 9-fold, DLTG produced blocky artefacts, and the CNN with data sharing recovered finer details without them. Without data sharing the CNN showed grainy noise-like artefacts, and the authors report, without a quantitative table, that it beat DLTG at 3-fold but not at the more aggressive rate.
The authors conclude that severe aliasing needs either more depth, which raises computation, or more training samples, and that data sharing addresses the limited data.
Noise robustness and the trainable λ
PSNR is computed as 10 log10(1/MSE), and the reconstruction PSNR is reported alongside the input PSNR.
The authors attribute DLTG's robustness to the sparse coding denoising of its K-SVD base.
CNN-NAD, trained without noise, kept performance similar to the other methods above 35 dB, but at high noise it degraded at about the rate of kt-SLR and L+S.
Above 38 dB CNN-AD was worse than CNN-NAD, but at higher noise it improved across the levels tested. After fine-tuning, λ rose to 0.5, and the authors read this as CNN and DLTG using the same iterative form with different required parameters. The training range was wide, so a narrower range may improve results, as the authors note.
Reconstruction cost and memory
A dynamic sequence took 8.21±0.02 s per reconstruction on a GeForce GTX 1080 for D5-C10(S), which the authors contrast with the 6.6 hours per subject that DLTG takes on CPU. Temporal extent makes the convolutions much heavier, so dynamic reconstruction is slower than 2D reconstruction.
The 2D D5-C5 model has about 0.6 million parameters, occupying 2.3MB in single precision, while the dynamic D5-C10(S) has 3.4 million parameters, about 13.6MB.
Training the 2D D5-C5 with a 1×256×256×1 input needs 335MB for activation maps. Dynamic D5-C10(S) with a 1×256×(256/8)×30 input needs 2.4GB for activation maps alone, and the largest minibatch that fitted on an 8GB GeForce GTX 1080 was 1.
At test time intermediate activations need not be stored, and D5-C10(S) ran on a 1×256×256×30 input on the same GPU.
Limitations
Experiments use retrospective single-coil data derived from SENSE reconstructions, and the application to full array-coil acquisition was not tested. Radial and spiral trajectories were not tested, so tolerance to other undersampling patterns is unknown.
The dataset of about 300 images is small, and the study relies on augmentation and on-the-fly masks to limit overfitting. Training was not extended beyond the reported schedules, so the effect of longer training with lower learning rates was not measured.
Data sharing makes highly dynamic regions inconsistent, and the cascade has to correct this internally.
Paper info
- Authors
- Jo Schlemper, Jose Caballero, Joseph V. Hajnal, Anthony Price, Daniel Rueckert
- Venue
- arXiv · Preprint
- First published
- 2017-4-8
- Added
- 2026-11-5
- Updated
- 2017-11-23
- Version
- v2
- arXiv
- 1704.02422
- Category
- cs.CV
- Original paper terms
- CC BY 4.0
- What we show
- Paper info, commentary and permitted figures from the original paper
AI commentary is a separate explanation from the original paper and may contain errors. The original paper and figures follow each source's terms of use and any rights noted separately.
Abstract
Inspired by recent advances in deep learning, we propose a framework for reconstructing dynamic sequences of 2D cardiac magnetic resonance (MR) images from undersampled data using a deep cascade of convolutional neural networks (CNNs) to accelerate the data acquisition process. In particular, we address the case where data is acquired using aggressive Cartesian undersampling. Firstly, we show that when each 2D image frame is reconstructed independently, the proposed method outperforms state-of-the-art 2D compressed sensing approaches such as dictionary learning-based MR image reconstruction, in terms of reconstruction error and reconstruction speed. Secondly, when reconstructing the frames of the sequences jointly, we demonstrate that CNNs can learn spatio-temporal correlations efficiently by combining convolution and data sharing approaches. We show that the proposed method consistently outperforms state-of-the-art methods and is capable of preserving anatomical structure more faithfully up to 11-fold undersampling. Moreover, reconstruction is very fast: each complete dynamic sequence can be reconstructed in less than 10s and, for the 2D case, each image frame can be reconstructed in 23ms, enabling real-time applications.
Quote from the paper
Jo Schlemper, Jose Caballero, Joseph V. Hajnal, Anthony Price, Daniel Rueckert (2017). A Deep Cascade of Convolutional Neural Networks for Dynamic MR Image Reconstruction. arXiv:1704.02422v2. https://arxiv.org/abs/1704.02422v2
BibTeX
@misc{schlemper2017deep,
title = {{A Deep Cascade of Convolutional Neural Networks for Dynamic MR Image Reconstruction}},
author = {Jo Schlemper and Jose Caballero and Joseph V. Hajnal and Anthony Price and Daniel Rueckert},
year = {2017},
eprint = {1704.02422},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/1704.02422v2}
}