Profile

Settings

Loading…

← Papers

Help

FAQ

Which features require signing in?

You can read the commentary, paper info, Model Structure and related papers of public papers without signing in. Sign in to manage your account or contact us about your inquiries.

Can I upload a PDF file?

Upload papers with an arXiv or DOI link; the commentary is public to everyone. Papers whose source and terms of use can't be verified, so the commentary can't be made public, can't be uploaded. Uploading PDF files and keeping papers private are for subscribers only, and a paper uploaded as a file is saved as private only. Searching for official info by title runs only when you press the button.

Are the figures and AI commentary accurate?

Figures come only from the original paper, and only those whose terms of use are verified are shown. The commentary is written by AI and may be wrong. Check important claims, numbers and figure context against the evidence in the original paper.

I want to report a copyright issue.

Terms of use and the source of the original paper are on the Paper info tab. If there's a problem, choose "Paper content, figures and copyright" under Contact us and send the paper link, the part in question, and evidence that you hold the rights. Receiving your report doesn't confirm any rights or remove anything right away. You can see the result of the review under My inquiries.

I forgot my password.

If you signed up with email, use Forgot password in the sign-in window to reset it with your verified email. If you signed up with Google, Naver or Kakao, change your password with that service.

What should I include in an inquiry?

Tell us which screen you were on and what you were doing when the problem happened, along with the paper link. Don't include personal information such as passwords, API keys, verification codes or phone numbers. Inquiries and replies are stored in Refivu and you can see them under My inquiries.

How do I delete my account?

In Settings, under My account, press Delete account. Review what will be deleted and complete identity verification to delete your account. For other requests, choose "Account" under Contact us.

Paper commentary

EchoAlign: Echocardiography foundation model with multilevel report alignment

EchoAlign learns one embedding per cardiac structure from the views that show it

  • Problem Existing echo models pair each video with the whole clinical report, including findings its view does not show. So a model can link a finding to scanner settings or other spurious signals instead of the image.
  • Method EchoAlign gives each cardiac structure its own embedding. It trains each structure only on the views that show it, using a visibility matrix.
  • Results EchoAlign reaches a mean AUROC of 0.890 on classification, compared to 0.880 for EchoPrime. It is the highest of the five public models compared.

Figure 3: T ext built from one report.The report of one training study and the texts built from it,
with truncated text

Fig. 3 T ext built from one report.The report of one training study and the texts built from it, with truncated text.

Original paper · CC BY 4.0 · Ahmed Aly, Darya Taratynova, Lotfi Abdelkrim Mecharbat, Roman A. Sandler, Joseph Z. Sokol, Joshua Penn, Klaus H. Maier-Hein, Numan Saeed, Mohammad Yaqub · EchoAlign: Echocardiography foundation model with multilevel report alignment · Original paper figure · Extracted the figure area from page 15 of the original PDF.

Why whole-report pairing misleads

Existing vision-language models, EchoCLIP and EchoPrime, pair every video with that whole report and summarize it into one embedding. A single view shows only part of the heart, so each video is trained against findings it cannot see.

The supervision of each view is spread across findings it does not depict, which dilutes the signal for the findings it does show. A worse risk is shortcut learning, where the model ties a finding to scanner settings, co-occurring diagnoses or demographics instead of the image evidence. Both problems weaken accuracy, anatomical grounding and clinical trust in the output.

Other model families avoid text or fix their task list. Supervised models such as PanEcho map each video to a fixed set of expert-labeled tasks, while EchoJEPA and EchoFM learn from unlabeled videos with no clinical text. The authors state that, to their knowledge, no earlier echo vision-language model aligns a separate embedding for each structure.

One embedding per structure, gated by views

The key idea is to split each report by cardiac structure and to match each structure's embedding only with the views that show that structure. The authors expected this to keep a video from learning findings it cannot depict, because each structure is supervised by a relevant view. It also lets a finding be read at the level of its own structure, such as the mitral valve embedding for mitral regurgitation.

Each study has a conclusion and findings for 12 cardiac structures, and from these the authors build three kinds of text. The study text joins the conclusion with all non-empty findings, the structure text is the single finding for one structure, and the video caption is the text each video is matched with.

The visibility matrix covers 66 views and gives each view-structure pair one weight from 0, 0.1, 0.3, 0.5, 0.8 and 1.0. The weights start from American Society of Echocardiography guidelines, with secondary references and dataset examples filling the gaps. The matrix encodes what a view is expected to show, while the report states what was observed, and dataset view labels are used only in pretraining.

From video patches to anatomical study embeddings

Each video goes through a TimeSformer, a video transformer with divided space-time attention that starts from Kinetics-400 weights. Text goes through a BERT-style encoder initialized from PubMedBERT, and a bias-free linear projection maps each 768-dimensional class-token output to 512 dimensions. Both encoders and their projections are fine-tuned during pretraining.

Twelve learned queries each attend to all of these tokens through an eight-head cross-attention layer, producing anatomical embeddings \\( A_i \\) for video \\( i \\). Each query's output is layer-normalized, projected to 512 dimensions and divided by its L2 norm, giving \\( z_{ik} \\). The architecture alone does not tie a query to a structure; the video-structure loss does that.

Two self-attention layers, each with four heads and a 1,024-unit feed-forward layer, let the tokens exchange information, and videos carry no positional encoding.

During training each anatomical query reads only from videos whose view shows its structure, and videos of unknown view still feed the global query. Because inference gives the study transformer no view information, each video has a 10% chance in training of being treated as showing every structure. At inference every video uses the unknown type, so evaluation needs no view labels.

Four losses and two-stage pretraining

All four losses are the standard CLIP loss on normalized embeddings, and they share one learned logit scale kept between 1 and 32. The video loss matches each global video embedding with its caption, and the video-structure loss matches each eligible anatomical embedding with the text of its structure. The study loss matches global study embeddings with study text, and the study-structure loss does the same for anatomical study embeddings, keeping structures without a finding as empty-finding targets.

The combined objective is \\( L_{align} = L_{video} + 0.5\\,L_{video\\text{-}structure} + 0.5\\,L_{study} + 0.1\\,L_{study\\text{-}structure} \\), so the structure-level terms weigh less than the video term.

Pretraining uses 60,782 studies from 150 clinical centers, with 2,651,674 videos and still images in the training data. Training ran on 64 AMD Instinct MI210 GPUs with a global batch of 1,024.

Detection with linear probes and text prompts

Across 68 tasks, EchoAlign's mean AUROC is 0.890 (95% CI 0.881 to 0.897), compared to 0.880 for EchoPrime and 0.860 for EchoCLIP. Each of these gaps is reported at P < 0.01, and in the private test set EchoAlign is higher than all five models. On MIMIC-IV-Echo the mean is not significantly different from EchoPrime (P = 0.190).

The authors read this as support for aligning each valve with its own report text.

With no training, each model is used as it is, and EchoAlign's prompt score is the mean similarity to present prompts minus the mean similarity to absent prompts, computed on the finding's own structure embedding. Across 68 tasks the mean AUROC is 0.796, compared to 0.692 for EchoPrime and 0.692 for EchoCLIP, with P < 0.01 against each. For tricuspid regurgitation the prompt score is 0.942, compared to 0.784 for EchoPrime and 0.664 for EchoCLIP.

The authors read this as evidence that the structure embedding itself carries the finding, a point the next section tests.

On those tasks the prompt score gives 0.830 and PanEcho gives 0.828. The two are not significantly different (P = 0.579), so the zero-shot score matches a supervised head there rather than beating it.

Severity grading and measurement links

Severity grading uses an ordinal probe, a standardized multinomial logistic regression whose expected-grade score is cut at points that maximize quadratic weighted kappa. EchoAlign's mean QWK is 0.530 (95% CI 0.511 to 0.544), the highest of the compared models. For tricuspid regurgitation the kappa is 0.47 (0.46 to 0.49), while the AUROC for severe cases is 0.98 (0.95 to 1.00) on 12 studies.

Text-prompt scores should also rise with reported grade, and on MIMIC-IV-Echo the median score does rise with each grade. Spearman's rank correlation is 0.673 for left atrial enlargement, 0.609 for tricuspid regurgitation and 0.580 for pulmonary hypertension. Spearman measures ordering, so these values show that higher grades get higher scores, not that the scores are calibrated to grade values.

Measurement uses a ridge regression probe on the same study features, with its regularization chosen on validation RMSE. Segmentation trains a convolutional decoder on frozen features for CAMUS, EchoNet-Dynamic and EchoNet-Pediatric.

Is the per-structure embedding doing the work?

The authors compare a finding read from its own structure embedding with the average of the 12 anatomical embeddings. The own-structure embedding reads the finding better, which the authors take to mean each embedding encodes the findings of the structure it was aligned to.

On the private validation set the assigned embedding ranks first for 14 of 34 findings and in the top three for 26. Its median rank is 2, so the own-structure embedding is usually near the top rather than always first.

Limitations

The study is retrospective, so the authors name a prospective trial as the next step to measure effects on missed diagnoses and reading time. Text-prompt scores depend on the wording of the prompts, and the prompts were selected on the private validation set.

CardioBench confidence intervals are wide, since HMC-QU has 50 videos from 25 patients and SegR WMA has four positive patients among 56.

Paper info

Authors
Ahmed Aly, Darya Taratynova, Lotfi Abdelkrim Mecharbat, Roman A. Sandler, Joseph Z. Sokol, Joshua Penn, Klaus H. Maier-Hein, Numan Saeed, Mohammad Yaqub
Venue
arXiv · Preprint
First published
2026-11-20
Added
2026-11-23
Updated
2026-11-20
Version
v1
arXiv
2611.27517
Category
cs.CV
Original paper terms
CC BY 4.0
What we show
Paper info, commentary and permitted figures from the original paper

AI commentary is a separate explanation from the original paper and may contain errors. The original paper and figures follow each source's terms of use and any rights noted separately.

Abstract

Echocardiography assesses the structure and function of the heart. Cardiologists read each study across several standard views and report the findings visible in those views by cardiac structure. AI foundation models can learn to analyze these studies from clinical reports, reducing annotation burden and supporting clinical interpretation. However, existing models are trained by pairing each video with the full clinical report, including structures and findings its view does not show. This mismatch lets a model associate a finding with incidental or spurious signals rather than its visual evidence, which limits accuracy, anatomical grounding and clinical trust. Here we introduce EchoAlign, a vision-language foundation model developed on 2.87 million echocardiographic videos and images from 159 clinical centers. EchoAlign aligns each cardiac structure, video and study with its report text, and a visibility matrix restricts supervision to the views that actually depict each structure. We compare it with five public foundation models on 0.47 million test videos across ten unseen external datasets from more than 25 clinical centers. EchoAlign achieves the highest mean AUROC of 0.890 (95% CI, 0.881 to 0.897) for classification and the highest mean quadratic weighted kappa of 0.530 (95% CI, 0.511 to 0.544) for severity grading. Across 62 clinical findings, EchoAlign provides one model that detects findings, grades their severity, estimates measurements and segments cardiac structures.

Quote from the paper

Ahmed Aly, Darya Taratynova, Lotfi Abdelkrim Mecharbat, Roman A. Sandler, Joseph Z. Sokol, Joshua Penn, Klaus H. Maier-Hein, Numan Saeed, Mohammad Yaqub (2026). EchoAlign: Echocardiography foundation model with multilevel report alignment. arXiv:2611.27517v1. https://arxiv.org/abs/2611.27517v1

BibTeX
@misc{aly2026echoalign,
  title = {{EchoAlign: Echocardiography foundation model with multilevel report alignment}},
  author = {Ahmed Aly and Darya Taratynova and Lotfi Abdelkrim Mecharbat and Roman A. Sandler and Joseph Z. Sokol and Joshua Penn and Klaus H. Maier-Hein and Numan Saeed and Mohammad Yaqub},
  year = {2026},
  eprint = {2611.27517},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.27517v1}
}

See related papersBrowse other papers

Paper preview
Account security

Connect Google account

If you connect a Google account, you can sign in with it too.

Refivu

Delete account

Refivu
Refivu

Sign up