Profile

Settings

Loading…

← Papers

Help

FAQ

Which features require signing in?

You can read the commentary, paper info, Model Structure and related papers of public papers without signing in. Sign in to manage your account or contact us about your inquiries.

Can I upload a PDF file?

Upload papers with an arXiv or DOI link; the commentary is public to everyone. Papers whose source and terms of use can't be verified, so the commentary can't be made public, can't be uploaded. Uploading PDF files and keeping papers private are for subscribers only, and a paper uploaded as a file is saved as private only. Searching for official info by title runs only when you press the button.

Are the figures and AI commentary accurate?

Figures come only from the original paper, and only those whose terms of use are verified are shown. The commentary is written by AI and may be wrong. Check important claims, numbers and figure context against the evidence in the original paper.

I want to report a copyright issue.

Terms of use and the source of the original paper are on the Paper info tab. If there's a problem, choose "Paper content, figures and copyright" under Contact us and send the paper link, the part in question, and evidence that you hold the rights. Receiving your report doesn't confirm any rights or remove anything right away. You can see the result of the review under My inquiries.

I forgot my password.

If you signed up with email, use Forgot password in the sign-in window to reset it with your verified email. If you signed up with Google, Naver or Kakao, change your password with that service.

What should I include in an inquiry?

Tell us which screen you were on and what you were doing when the problem happened, along with the paper link. Don't include personal information such as passwords, API keys, verification codes or phone numbers. Inquiries and replies are stored in Refivu and you can see them under My inquiries.

How do I delete my account?

In Settings, under My account, press Delete account. Review what will be deleted and complete identity verification to delete your account. For other requests, choose "Account" under Contact us.

Paper commentary

Unlocking Noise-Resistant Vision: Key Architectural Secrets for Robust Models Against Gaussian Noise

Architecture choices, not model type, drive robustness to Gaussian noise in vision models

  • Problem Earlier robustness studies compared whole architectures, so they could not tell which internal design choice helps. Many also mixed several corruptions in one test.
  • Method The authors isolate one factor at a time under Gaussian noise. They rank 1,174 pretrained timm models with and without noise, then derive bounds on the stem and pooling layers that explain the ranks.
  • Results The authors prove stem noise gain is bounded at rate k to the power minus two.

Why whole-architecture comparisons fall short

Earlier studies found that vision transformers often degrade less than residual networks under various corruptions. Those comparisons usually treat each architecture as one block, so they can't say which internal choice matters. Many also mix several corruptions, such as brightness changes and blur, in a single evaluation. The authors isolate one factor at a time under Gaussian noise instead.

Gaussian noise is a practical choice for two reasons. Aggregated perturbations tend toward a Gaussian shape through the central limit theorem. Sensor readout and thermal noise also produce it in real imaging pipelines.

ImageNet-1K rankings of pretrained ViTs

The authors measured top-1 accuracy of 1,174 pretrained timm models on ImageNet-1K, with and without noise. Noise was added to the raw image before resizing, center cropping and mean-std normalization. The noise scale factor range was (0.2, 0.44) for ImageNet-1K. A robust model should lose less accuracy than others, so the authors compare ranks before and after noise.

RankDiff is the rank under noise minus the clean rank, so a more negative value means a larger gain.

vit base patch32 224.augreg in1k moved from 74.90 to 58.44 top-1 and carries a RankDiff of -506. Its patch-16 sibling, vit base patch16 224.augreg in1k, moved from 79.15 to 62.21 with a RankDiff of -375. The patch-32 model has lower clean accuracy but gained more rank under noise. The authors report similar patch-32 advantages across several other pretrained weights.

The same pattern appears for native resolution, where 224 models often beat matched 384 models. Noise enters before the resize, so a 224 model applies stronger downsampling to the noise than a 384 model does. A counterfactual control moves the noise after resizing, and the gap changes sign. The authors read the default resolution trend as pre-model downsampling, not intrinsic robustness of low-resolution backbones.

A RankDiff value on its own doesn't measure robustness, so the authors compare model pairs instead.

Why Gaussian noise is the worst case

The argument linearizes the model f at the input x. The Jacobian \(J_f(x)\) maps a perturbation \(\Delta\) to the first-order change in the output. The second-order remainder is bounded by \(L(x)/2\) times the squared norm of \(\Delta\).

Theorem 3.1 takes any zero-mean perturbation whose covariance satisfies \(\Sigma_\Delta \preceq \sigma^2 I_d\). For such perturbations the expected squared feature error is at most \(\sigma^2\) times the squared Frobenius norm of \(J_f(x)\), up to a higher-order term. For Gaussian noise with variance \(\sigma^2\), the same leading term appears, so Gaussian noise reaches the bound.

The result holds only to leading order, so it doesn't rank every corruption exactly.

Other corruptions with bounded covariance can be compared to Gaussian noise with the same variance. The authors set the effective variance of corruption C at severity s as \(\sigma_C(s)\). Averaging over a data distribution gives a bound in terms of the expected squared Jacobian norm.

Stem kernels and anti-aliased downsampling

In a ViT the stem is the patch embedding, and the patch size sets its kernel size. The authors model the stem as a linear, shift-invariant kernel \(K_k\) of size k by k. Its per-pixel noise gain is the output noise energy divided by the number of output pixels. Under Parseval's identity, this gain equals the squared Frobenius norm of the kernel.

The key assumption is a radial low-pass envelope at scale 1/k. The Fourier magnitude of \(K_k\) is bounded by \((1+\beta k r)^{-1-\delta}\) for some positive \(\beta\) and \(\delta\). Under this assumption the gain is bounded by a constant C times \(k^{-2}\). The authors add that the \(k^{-2}\) rate is achievable. Doubling the stem kernel size roughly quarters the output noise energy, about -6 dB.

For anti-aliased downsampling by factor s, the filter size g(s) scales between \(c_1 s\) and \(c_2 s\). The filter is applied before subsampling, and the gain is normalized by output pixels. The per-output-pixel gain is bounded by a constant C' times \(s^{-2}\), and that rate is tight up to constants.

The authors trained ResNet-50 from scratch on five fine-grained datasets to test the stem effect. Larger kernel sizes and lower evaluated resolutions raised accuracy under additive Gaussian noise. The authors describe the error decrease as tending to be quadratic in kernel size and downsampling strength. The resolution effect is read as a pre-resize pipeline effect, not as intrinsic backbone robustness.

Average versus max pooling

ResNet types T and D pair average pooling with a convolution, while C and S use a strided 1 by 1 convolution instead. The authors changed only the stem pooling of ResNet-50, choosing max, nearest-neighbor or average pooling. Average pooling gave the highest noisy test accuracy on all five datasets. On Oxford-IIIT Pet, noisy test accuracy was 49.3 with average pooling, compared to 41.8 for max pooling.

The theory covers one pooling window of size k with clean values S and i.i.d. Gaussian noise. Average pooling is unbiased, and its error variance equals \(\sigma^2/k\). Max pooling has a non-negative expected error, which means a positive bias. In the uniform-signal case, the max-pooling error grows at most logarithmically in k, through the bound \(2\log(2k)+2\) on \(E[A_k^2]\).

Under adversarial perturbation, average pooling has an \(\ell_2\) Lipschitz constant of \(k^{-1/2}\), while max pooling is at most 1.

For a 2 by 2 window, the authors' remark puts the variance reduction at about -6 dB. Nearest-neighbor pooling is unbiased with error variance \(\sigma^2\), so average pooling beats it by a factor of k in MSE. The theory covers one window and i.i.d. Gaussian noise, so it doesn't prove the full network's behavior.

Normalization and the CLIP gap

CLIP ViTs and supervised ViTs share nearly the same architecture but differ in pretraining and normalization. In the ViT-B/16 224 comparison, vit base patch16 clip 224.openai ft in12k in1k has a RankDiff of +74. Supervised checkpoints in the same table have negative values, such as -375 for vit base patch16 224.augreg in1k.

The authors swapped the OPENAI constants for the INCEPTION constants when fine-tuning on Oxford-IIIT Pet. For vit base patch16 clip 224.openai ft in12k in1k, validation accuracy under noise rose from 77.7 to 87.3. The authors report that IMAGENET constants also produced similar vulnerability for ViTs. Ablations led them to call the mean-std choice the core factor.

Normalization computes \(N_{\mu,\sigma}(x)=(x-\mu)/\sigma\) per channel. A pixel-space noise \(\eta\) becomes \(\eta/\sigma\) after normalization, so a smaller \(\sigma\) amplifies it. Theorem 6.1 bounds the output change by \(L_z\) times \(\|\eta/\sigma\|_2\), which is at most \(L_z/\sigma_{\min}\) times \(\|\eta\|_2\).

The INCEPTION standard deviations are (0.5, 0.5, 0.5), while the CLIP standard deviations have a smallest value of 0.26130258. The ratio of the two worst-case bounds is about 1.91. This 1.91 factor bounds worst-case sensitivity and is not a measured accuracy change.

Where the findings stop

The models are timm pretrained checkpoints and controlled runs on specific datasets. Generalization to other domains such as medical imaging or video was not tested.

Downsampling helps only while the noise reduction outweighs the clean-margin loss from less image detail. In the resolution sweep, the near-optimal band was 224, 256, 288 and 320 for the 224 checkpoint. For the 384 checkpoint the band was 352 and 384. The beneficial regime depends on the checkpoint and the image.

Paper info

Authors
Bum Jun Kim, Makoto Kawano, Yusuke Iwasawa, Yutaka Matsuo
Venue
International Conference on Machine Learning · Published
First published
2026-9-29
Added
2026-11-25
Original paper terms
Check in the original ↗
What we show
Paper info and commentary

AI commentary is a separate explanation from the original paper and may contain errors. The original paper and figures follow each source's terms of use and any rights noted separately.

Quote from the paper

Bum Jun Kim, Makoto Kawano, Yusuke Iwasawa, Yutaka Matsuo (2026). Unlocking Noise-Resistant Vision: Key Architectural Secrets for Robust Models Against Gaussian Noise. International Conference on Machine Learning. https://proceedings.mlr.press/v306/kim26w.html

BibTeX
@article{kim2026unlocking,
  title = {{Unlocking Noise-Resistant Vision: Key Architectural Secrets for Robust Models Against Gaussian Noise}},
  author = {Bum Jun Kim and Makoto Kawano and Yusuke Iwasawa and Yutaka Matsuo},
  year = {2026},
  journal = {International Conference on Machine Learning},
  url = {https://proceedings.mlr.press/v306/kim26w.html}
}