Profile

Settings

Loading…

← Papers

Help

FAQ

Which features require signing in?

You can read the commentary, paper info, Model Structure and related papers of public papers without signing in. Sign in to manage your account or contact us about your inquiries.

Can I upload a PDF file?

Upload papers with an arXiv or DOI link; the commentary is public to everyone. Papers whose source and terms of use can't be verified, so the commentary can't be made public, can't be uploaded. Uploading PDF files and keeping papers private are for subscribers only, and a paper uploaded as a file is saved as private only. Searching for official info by title runs only when you press the button.

Are the figures and AI commentary accurate?

Figures come only from the original paper, and only those whose terms of use are verified are shown. The commentary is written by AI and may be wrong. Check important claims, numbers and figure context against the evidence in the original paper.

I want to report a copyright issue.

Terms of use and the source of the original paper are on the Paper info tab. If there's a problem, choose "Paper content, figures and copyright" under Contact us and send the paper link, the part in question, and evidence that you hold the rights. Receiving your report doesn't confirm any rights or remove anything right away. You can see the result of the review under My inquiries.

I forgot my password.

If you signed up with email, use Forgot password in the sign-in window to reset it with your verified email. If you signed up with Google, Naver or Kakao, change your password with that service.

What should I include in an inquiry?

Tell us which screen you were on and what you were doing when the problem happened, along with the paper link. Don't include personal information such as passwords, API keys, verification codes or phone numbers. Inquiries and replies are stored in Refivu and you can see them under My inquiries.

How do I delete my account?

In Settings, under My account, press Delete account. Review what will be deleted and complete identity verification to delete your account. For other requests, choose "Account" under Contact us.

Paper commentary

Delayed Effects of Temporary Weight Decay in Muon Pretraining

Temporary weight decay can hurt at removal yet help at the final budget

  • Problem Temporary optimization schedules are usually judged by loss at the moment they end. That can misrank them, because the runs keep diverging after removal and the gap changes later.
  • Method The authors apply weight decay only inside a fixed window of Muon training. Decay shrinks the weights, which leaves them with smaller norms and larger relative steps after removal.
  • Results A schedule picked at 162M and moved to 1.4B without retuning trails no decay by 0.26 nats at removal. It finishes 0.028 nats better, which is the reason to judge schedules at the intended final budget.

Why judging at removal can mislead

A temporary weight decay window can look harmful at the moment it ends and beneficial much later. In the 1.4B run of Figure 1, decay at λ = 0.15 covered the first 44% of training over 28,000 updates. That schedule had been picked at 162M and carried over without any retuning. At removal, the treated run sits 0.26 nats behind no decay.

Figure 1: A temporary intervention can be harmful at removal and beneficial much later.1.4B, FineWeb100B,
28,000 updates. Decay (λ = 0.15) is applied for the f…

Figure 1 A temporary intervention can be harmful at removal and beneficial much later.1.4B, FineWeb100B, 28,000 updates. Decay (λ = 0.15) is applied for the first 44% of training; the schedule was selected at 162M and transferred without retuning. (a) Validation-loss difference from no decay; constant decay0.01is shown for comparison. Temporary decay is 0.26 nats worse at removal, crosses no decay at73%of training, and finishes 0.0275 nats better. (b) Layer-averaged weight norms relative to no decay. The dashed line marks removal; the norm deficit persists afterward.

Original paper · CC BY 4.0 · Md Rifat Arefin, Ravid Shwartz-Ziv, Ernie Chang, Chinnadhurai Sankar, Rylan Conway, Aristide Baratin, Irina Rish, Adithya Sagar, Patrick Huber · Delayed Effects of Temporary Weight Decay in Muon Pretraining · Original paper figure · Extracted the figure area from page 2 of the original PDF.

The reason is that removal doesn't return the two runs to a shared state. Both runs follow the same explicit update rule afterward, yet they carry different parameters and optimizer states. Their loss gap can therefore keep changing long after the intervention has ended. Judging a schedule at removal can pick one that is inferior at the intended budget, or reject one that would later help.

Earlier work showed that temporary changes early in training can leave lasting effects on the learned solution. Golatkar et al. (2019) found that weight decay matters disproportionately during early learning.

Weight decay makes a clean test case, since turning it off separates its direct shrinkage from the state it leaves behind. Muon ties weight norms to later updates, so a smaller weight norm enlarges the update relative to the weights. Temporary decay can therefore change later optimization even after its coefficient returns to zero.

Temporary decay as a controlled intervention

Weight decay makes a clean lever here, because switching it off separates its direct shrinkage from the state it leaves behind. The runs are decoder-only Transformers trained with Muon, which orthogonalizes the momentum update, at 162M, 405M, 1.4B and 3.4B parameters. The default configuration has no initial warmup, and the compute-optimal budget is about 20 tokens per parameter.

The update applies decoupled weight decay to each hidden-layer weight matrix, so the step first shrinks the weights and then subtracts the Muon update. The rule is W_{t+1} = (1 − η_t λ_t) W_t − η_t U_t, with λ_t = λ·1{s ≤ t < e}. The coefficient is zero outside that window, and embeddings and the output head receive no decay. The end of the window, e, is what the authors call removal.

Every loss is next-token cross-entropy on held-out validation tokens, reported in nats per token. The authors compute Δ_t as the intervention loss minus the reference loss at update t, so negative values mean an improvement. Early windows start within the first 20% of training, and the late window starts at 60%. The best sampled constant is the best constant coefficient tried for that scale, and the best reference is the better of that baseline and no decay.

No decay alone serves when the question is what the window itself changes, because constant decay adds norm dynamics of its own.

Start time, duration and the evaluation point

Start time alone flips the sign of a temporary decay window's effect in this setup. Figure 2 shows the start-time effect and the 405M evaluation point together. So the sign reversal comes from timing, not from a difference in total shrinkage.

Figure 2: Start time changes the sign; evaluation horizon changes the ranking.(a) Final loss difference for 10%
windows by start time; dashed lines show the be…

Figure 2 Start time changes the sign; evaluation horizon changes the ranking.(a) Final loss difference for 10% windows by start time; dashed lines show the best sampled constant. (b) At 405M, the ranking of early starts reverses when evaluated after equal post-removal training.

Original paper · CC BY 4.0

Duration matters more than the coefficient for the final loss in this grid. At fixed coefficient, changing window duration moves the final improvement by 0.026 to 0.035 nats. At fixed duration, changing the coefficient moves it by only 0.007 to 0.010 nats.

Longer windows also apply more total decay, so duration and shrinkage can't be separated directly. The authors match the total log-shrinkage at about 2.1 to separate the two effects.

The best schedule in this grid is λ = 0.15 over the first 44% of training. It improves on the best sampled constant by 0.0335 nats. That window is also the longest in the grid, so these runs don't locate the optimal duration. So a temporary schedule can't be ranked from its loss at removal or from its total shrinkage alone. Start time, duration and evaluation horizon can each change the comparison, because they alter the state at removal or the later optimization.

What the decay window leaves behind

After removal, the update rule is identical in both runs, so any lasting effect must sit in parameters or optimizer state built during the window. In the transferred 1.4B run, norms fall to 12 to 16% of their no-decay values at removal and stay at 60 to 66% at the final checkpoint. The 162M mechanism runs show the same qualitative deficit, so the pattern isn't specific to the transferred schedule.

The relative step size α_t is the perpendicular part of the weight change, divided by the weight norm. The projection removes the decay term, since that term is parallel to W. At 162M, early decay lowers the norms and raises α_t. After removal, the relative steps move toward the no-decay trajectory but stay larger until the end of training.

At update 2,800, the inverse norm ratio is 1.17, while the relative-step ratio is 1.07.

An early learning-rate boost acts as the opposite perturbation: it raises weight norms and leaves later relative steps smaller. To test whether the trajectory itself matters, a variant of Hyperball holds every weight norm at its initial value and replays the measured α_t. Across three replay seeds, the early-decay trajectory improves final loss by 0.022 to 0.023 nats over the no-decay trajectory.

The Muon runs themselves differed by 0.0171 nats, so the replay reproduces both the ordering and a similar magnitude.

Swapping in no-decay steps for the first 320 updates accounts for 0.0181 of the 0.0221-nat replay difference. Replaying only the early-decay trajectory during the intervention improves loss by just 0.0003 nats. Most of the replay advantage therefore traces back to the altered steps after decay has been removed.

Replaying the relative-step trajectory

A correlation between smaller norms and larger relative steps doesn't show that the steps matter for loss. So the authors hold every weight norm fixed and replay the measured relative-step trajectory directly. That trajectory is averaged over the six matrix families. The source Muon runs differed by 0.0171 nats, so the replay reproduces both the ordering and a similar magnitude.

Figure 5: Fixed-norm replay reproduces the post-removal gain.162M, FineWeb-Edu, 3,200 updates. (a) Relative-step
trajectories measured from the source Muon run…

Figure 5 Fixed-norm replay reproduces the post-removal gain.162M, FineWeb-Edu, 3,200 updates. (a) Relative-step trajectories measured from the source Muon runs and replayed at fixed weight norms. (b) Final loss relative to Muon without decay; dots show three replay seeds and the last two bars switch trajectory at update 320.

Original paper · CC BY 4.0

Figure 5 shows the replayed step trajectories and the final loss of each replay variant. A trajectory swap localizes where the difference arises. So most of the replay advantage comes from the altered steps after decay has been removed.

The replay uses a modified optimizer and averages the relative step over matrix families. That setup doesn't show that relative steps are the only relevant state.

This result sets up the next question, which is why the relative-step gap shrinks so slowly. The authors write the cosine between the weights and the update as c_t and the update-to-weight ratio as a_t. From update 400 on, the absolute cosine is below 0.20, so the ratio of relative step to a_t stays above 0.9798. Muon updates of equal norm give a recurrence for the inverse squared ratio, which grows by an increment tied to κ_t.

At 162M, κ_t is similar between the two runs, so the offset in the inverse squared ratio stays roughly constant while the total grows.

Why the relative-step gap closes slowly

The relative-step gap closes slowly because the norm offset behind it stays almost fixed while the total grows. Let a_t be the norm of ΔW_t divided by the norm of W_t, and let c_t be the cosine between W_t and ΔW_t. Since α_t equals a_t times the square root of 1 minus c_t squared, the relative step tracks the norm ratio closely once the cosine is small.

From update 400 on, the absolute cosine stays below 0.20, so α_t over a_t exceeds 0.9798. With equal projected update norms, Muon's recurrence gives 1/a_{t+1}² minus 1/a_t² ≈ 1 + 2κ_t, where κ_t is the inner product of W_t and ΔW_t over the squared norm of ΔW_t.

If the recurrence increments match between the early-decay and no-decay runs, their offset in 1/a_t² stays roughly constant. Meanwhile 1/a_t² keeps growing, so the fixed offset becomes a smaller fraction of the total. Over that span the relative-step ratio falls only from about 1.6 to 1.8 down to about 1.1.

The learning-rate boosts give an opposite-sign check, with offsets that follow the same recurrence. At 1.4B, the authors don't have relative-step logs for the no-decay run, so they can't test the recurrence as directly. The absolute deficit therefore isn't fixed, but it gets smaller relative to the growing weight norms, which matches the slow recovery at 162M.

The norm account explains the delayed influence, but it doesn't explain why early and late windows have opposite effects. Continuing decay at 0.10 after the window keeps relative steps larger, yet gives a smaller final improvement of 0.0071 nats versus 0.0171 nats. Next, the authors check scale transfer: a schedule selected at 162M is moved to 1.4B without retuning.

Scale, warmup and optimizer checks

Table 1 pits a 10% window starting at initialization against no decay and the best sampled constant at each scale. At 162M, the 0.3, 10% schedule reaches 3.3710, while no decay gives 3.3860 and the best constant gives 3.3768. At 405M, the same kind of window reaches 3.0287, against 3.0537 for no decay. At 1.4B, the 0.2, 10% window ends at 2.6506, and the transferred 0.15, 44% schedule ends at 2.6479.

At 3.4B, the 0.2, 10% window reaches 2.4720, compared with 2.4832 for no decay. Across 3.4B, every tested early schedule improves loss and mean accuracy, so the scale check ends on a positive result.

Table 1: Early decay across scale.FineWeb100B, compute-optimal budgets, no warmup. “Best const.” is the best
sampled constant coefficient; full sweeps are in A…

Table 1 Early decay across scale.FineWeb100B, compute-optimal budgets, no warmup. “Best const.” is the best sampled constant coefficient; full sweeps are in Appendix C and the 3.4B configurations are in Appendix K.

Original paper · CC BY 4.0

The authors test robustness to training length, with 162M trained for 64,000 updates, 20 times the compute-optimal budget. Extending decay beyond warmup beats the constant at 405M and 1.4B, and restores a clear advantage at 162M and 405M. In a 16,000-update 162M run with warmup, decay is 0.0237 nats worse than no decay at update 8,000. By update 14,400 the same run has decay 0.0373 nats better than no decay, so warmup doesn't remove the delayed crossover.

Early decay also helps with SwiGLU MLPs and with AdamW at 162M, but it doesn't help with AdamW at 405M.

The domain ranking changes between those two evaluations, which the authors report alongside exploratory corpus-level analyses. The authors conclude that the effect is robust to several training variations but isn't optimizer-independent.

To test whether the mechanism depends on multiplicative decay, the authors add an off-diagonal Gram penalty during an early window.

A Gram penalty as a second intervention

The authors add an off-diagonal Gram penalty during an early window, applied to the value, output and down-projection matrices, and Muon orthogonalizes the combined gradient. The penalty is \[ R_t=\mu\,\mathbf{1}\{0\le t<e\}\sum_{\ell=1}^{L}\sum_{W\in\{W_V,W_O,W_{\text{down}}\}}E(W_\ell), \quad E(W)=\lVert \mathrm{OffDiag}(W^\top W)\rVert_F^2 \] At 162M, 10% windows starting at 0%, 20% and 60% change final loss by -0.0147, -0.0080 and +0.0209 nats.

Across five paired 162M runs, the early penalty improves final loss by 0.0142 nats compared to no regularization.

The raw penalty gradient has a radial part that changes the weight norm and a tangential part that mostly changes direction. Applied after the Muon update, the radial part nearly matches the full penalty, while the tangential part has little effect. So the post-removal norm and step dynamics are not unique to multiplicative decay, though this doesn't make norm reduction generally beneficial.

Where the delayed weight decay results stop

The results hold only in the regimes the authors tested, and they say so directly. The numerical decay coefficients aren't universal, so the values that work here don't carry over as fixed settings. Detailed mechanism measurements are concentrated at 162M, so the norm and relative-step analysis rests mostly on one scale.

Early decay doesn't improve every tested optimizer setting, and AdamW at 405M shows no gain. Early decay still improves loss with SwiGLU MLPs and with AdamW at 162M. The downstream evaluations at 405M and 1.4B don't show a clear advantage over constant decay. At 3.4B, early decay improves mean zero-shot accuracy over all tested references.

Whether similar delayed dynamics arise across other optimizers and temporary interventions stays an open question.

The norm account explains how an early intervention keeps acting after removal, but it doesn't say which relative-step trajectory helps. Larger relative steps aren't universally better. Norms may not be the only persistent state, and the authors don't claim they are.

For practice, temporary schedules should be judged at the budget where the model will be used, not only at removal. The Gram penalty at 1.4B needs retuning of its strength, so that second intervention doesn't transfer cleanly. Early Gram regularization does improve loss at 162M and 405M across both tested datasets.

Paper info

Authors
Md Rifat Arefin, Ravid Shwartz-Ziv, Ernie Chang, Chinnadhurai Sankar, Rylan Conway, Aristide Baratin, Irina Rish, Adithya Sagar, Patrick Huber
Venue
arXiv · Preprint
First published
2026-11-13
Added
2026-11-16
Updated
2026-11-13
Version
v1
arXiv
2611.17876
Category
cs.LG · cs.CL
Original paper terms
CC BY 4.0
What we show
Paper info, commentary and permitted figures from the original paper

AI commentary is a separate explanation from the original paper and may contain errors. The original paper and figures follow each source's terms of use and any rights noted separately.

Abstract

A temporary optimization intervention can increase validation loss when it ends yet reduce it at the final training budget. We demonstrate this with temporary weight decay in Muon-trained decoder-only Transformers with 162M, 405M, 1.4B, and 3.4B parameters. For models up to 1.4B parameters, moving a fixed-duration decay window from early to late training reverses its final effect. At 162M, changing window duration alters final loss even at approximately matched total shrinkage. Most strikingly, a schedule selected at 162M and transferred without retuning to 1.4B is 0.26 nats worse than no decay when removed, overtakes it only after 73% of training, and ultimately finishes 0.028 nats better while also outperforming the best sampled constant-decay baseline. Early decay leaves a persistent weight-norm deficit, which keeps relative steps larger after the intervention ends. An approximate norm-dynamics recurrence captures the slow convergence of these relative steps, and fixed-norm replays of the measured trajectories reproduce the performance ordering and a similar loss difference. At 162M and 405M, norm-reset experiments show that smaller weight norms at the end of the decay window explain most of the final loss improvement. A separate Gram intervention exhibits related post-removal norm and relative-step dynamics. These results show that temporary optimization schedules can have delayed effects long after removal and should therefore be evaluated at the intended final training budget, not only at removal.

Quote from the paper

Md Rifat Arefin, Ravid Shwartz-Ziv, Ernie Chang, Chinnadhurai Sankar, Rylan Conway, Aristide Baratin, Irina Rish, Adithya Sagar, Patrick Huber (2026). Delayed Effects of Temporary Weight Decay in Muon Pretraining. arXiv:2611.17876v1. https://arxiv.org/abs/2611.17876v1

BibTeX
@misc{arefin2026delayed,
  title = {{Delayed Effects of Temporary Weight Decay in Muon Pretraining}},
  author = {Md Rifat Arefin and Ravid Shwartz-Ziv and Ernie Chang and Chinnadhurai Sankar and Rylan Conway and Aristide Baratin and Irina Rish and Adithya Sagar and Patrick Huber},
  year = {2026},
  eprint = {2611.17876},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.17876v1}
}

See related papersBrowse other papers

Paper preview
Account security

Connect Google account

If you connect a Google account, you can sign in with it too.

Refivu

Delete account

Refivu
Refivu

Sign up