Paper commentary
UltraVoxelGS: Voxel-First Feed-Forward Gaussian Splatting for 3D Ultrasound Reconstruction
UltraVoxelGS predicts 3D ultrasound scenes in seconds instead of minutes of optimization
- Problem Gaussian splatting for ultrasound fits each scene by per-scene optimization, which takes 10-20 minutes per scene. That is too slow for live feedback during freehand scanning.
- Method UltraVoxelGS lifts posed ultrasound slices into one shared voxel grid and predicts Gaussians from it in a single forward pass. Instead of optimizing each scene, it skips per-scene fitting entirely.
- Results On Dataset A, UltraVoxelGS reaches a PSNR of 24.29 with its rendering adaptation enabled. Inference takes about 10 seconds, over 35 times faster than the 10-20 minute baselines.
Why per-scene fitting blocks live ultrasound feedback
Freehand 2D ultrasound leaves the operator to work out which anatomy is still unseen, so a live 3D view could guide scanning. A live 3D view could give immediate spatial feedback, which is why real-time reconstruction matters during acquisition. Gaussian splatting can render such a view quickly, because its explicit primitives support efficient rasterization-based rendering.
The ultrasound adaptations of Gaussian splatting still reconstruct each scene through iterative optimization. So the bottleneck sits in fitting the scene, not in drawing it, and the reported cost is 10-20 minutes per scene.
Classical interpolation is cheap, yet it treats ultrasound frames as generic intensity images and misses cumulative attenuation.
Feed-forward Gaussian prediction works in natural imaging because neighbouring views overlap densely and look alike. Freehand ultrasound breaks both assumptions, because each frame is a thin 2D slice that shares at most a one-dimensional intersection with another frame. Acoustic anisotropy adds a second problem: the same tissue can look different from different probe directions.
So even the shared line doesn't guarantee matching brightness, and dense cross-view matching has too little overlap to work with. Multi-view feed-forward methods handle several frames at once, but their cost grows with the number of input views.
UltraVoxelGS answers this by lifting posed slices into a unified voxel support, then predicting Gaussians from that shared support. This turns reconstruction into a feed-forward voxel-to-Gaussian pass, which avoids long per-scene optimization.
Building a shared voxel support before prediction
The core move is to reverse the usual order: posed slices are first gathered into one shared voxel grid, and only then are Gaussians predicted. Pixel-aligned feed-forward methods predict primitives per view and aggregate them afterward, which the authors argue is a poor fit when views barely overlap. Ultrasound slices share at most a line-like intersection, so the lifted pixels stay irregular observations on sparse 2D surfaces.
The grid is controlled by its voxel resolution XYZ rather than by the raw observation count N|Ω|, so prediction cost is tied to the grid. Figure 2 contrasts the per-view pixel-aligned route with the voxel-aligned route used here.

Figure 2 :Optical feed-forward GS paradigm: (a) Natural images provide dense cross-view overlap and photometric consistency. (b) Existing methods predict pixel-aligned primitives from individual views.Our ultrasound-specific feed-forward GS paradigm: (c) Ultrasound slices share minimal intersection and exhibit view-dependent intensity. (d) We lift posed slices into a unified voxel support and predict Gaussians from the shared voxel support.
Original paper · CC BY 4.0 · Wang, Yue, Chen, Haoxin, Guo, Xiaoqing · UltraVoxelGS: Voxel-First Feed-Forward Gaussian Splatting for 3D Ultrasound Reconstruction · Original paper figure · Extracted the figure area from page 2 of the original PDF.Each pixel p = (u, z) of frame i is first lifted to a 3D world position x_i(p) using its probe pose. For each voxel centre x, the method takes up to k nearest lifted observations within a radius α. The voxel intensity is a local inverse-distance weighted average of those observations, with ω_{i,p}(x) = (||x − x_i(p)||_2 + δ)^(-1). The constants δ and ϵ keep the computation numerically stable.
Restricting the average to a local top-k neighbourhood stops distant observations from filling voxels and limits spread from shadowed regions.
The resulting voxel support is shared, but a full-volume prediction becomes expensive for dense sequences. The authors rely on thin-slab locality: each frame sees only its imaging slice and nearby acoustic slab. For each target frame, a local block B_m is cut from the consolidated voxel support, so prediction stays on dense multi-view context.
Predicting Gaussians from local voxel blocks
Predicting Gaussians over the whole voxel support would be too costly for dense ultrasound sequences, so UltraVoxelGS works on local blocks instead. The authors justify this with thin-slab locality, since each frame observes only a thin imaging slice and its nearby acoustic slab. Voxels far from that slab contribute little to the rendering of the frame, so prediction can stay inside a smaller region.
For each target frame, a block Bm is extracted from the consolidated voxel support, and Gaussian primitives are predicted only within this block. Because the block is carved from a support that already fuses observations across the entire input sequence, its prediction still sees multi-view context rather than a single frame.
The block is tokenized into regular voxel patches Pj of size n×n×n, and these patches serve as the tokens for the predictor. The Transformer-based predictor Φθ maps these voxel tokens to voxel-aligned Gaussian primitives, and the block's output is the union of the per-patch Gaussians. Each predicted Gaussian carries a center, a covariance, nine second-order spherical-harmonic coefficients ρ for anisotropic reflection, and an attenuation coefficient β.
Keeping reflection and attenuation as separate outputs lets the later rendering step treat them differently.
Neighbouring blocks overlap, so one spatial location can receive several predicted parameter vectors from different local predictions. The fusion rule averages the duplicated predictions at a location, using the number of predictions Kx at that location. Locations with only one prediction keep their value, because Kx equals 1 there. The authors argue this local-to-global assembly is more than a shortcut, because each local prediction stays tied to the acoustic slab of its target slice.
This avoids redundant whole-support prediction while keeping the slice-relevant information needed for accurate rendering.
Rendering reflection and attenuation separately
UltraVoxelGS models the training image as anisotropic reflection multiplied by cumulative attenuation along depth. For a target frame m and pixel p, the reflection response R_m depends on the acoustic propagation direction d_m(p) under pose T_m. The attenuation term is an exponential of the integral of the attenuation coefficient β_m from depth 0 to z.
This formulation treats the target slice as ultrasound physics rather than as a generic intensity image.
To render this model from Gaussians, the authors collect the Gaussians that contribute to each pixel under pose T_m. The anisotropic reflection term is a weighted sum of second-order spherical-harmonic responses SSH(d_m(p); ρ_g) over those Gaussians. The local attenuation coefficient is a weighted sum of the per-Gaussian β_g values using the same contribution weights.
The transmittance A_m(p) accumulates this attenuation along depth, and the rendered intensity is the product A_m(p) times the reflection term. Because the two factors stay separate inside the renderer, the authors call the scheme decoupled.
Training minimizes a squared error between rendered and observed intensities over every supervised frame and pixel. A weighted overlap consistency term is added to the image loss, with λ balancing the two terms. The overlap term pulls each prediction at a shared location toward the fused average over its K_x overlapping predictions. The image term supervises the final intensity without any explicit reflection or attenuation annotations.
Decoupled rendering is therefore trained from images alone, and the overlap term handles predictions that diverge across overlapping slabs.
The ablation in Table 2 shows that adding DRA lifts Dataset A PSNR from 14.46 to 19.76 when the feed-forward voxel prediction is kept. The authors did not report a separate reflection-only or attenuation-only training run in this section.
Adapting appearance from a nearby slice at render time
Interpolating into the shared voxel support tends to flatten local texture, which costs sharpness on each individual slice. The authors borrow sharper evidence from a nearby observed frame, which serves as an appearance anchor for the target view. For a target pose t, they pick the observed frame i*(t) whose probe centre is nearest, using the distance ||o_i − o_t||.
This choice rests on the observation that probe poses close together trace similar acoustic paths and therefore produce similar images.
Only the appearance parameters ρ and β get copied, so the transient copy changes while the geometry c and Σ stays frozen. The adaptation objective in Eq. 12 renders the copy at the anchor's pose and matches that render to the anchor frame Pt. A γ term pulls ρ toward its feed-forward value ρ0, and an η term does the same for β toward β0. The first term carries the image match, while the two regularisers keep the update close to the feed-forward appearance.
After the target pose is rendered, the adapted copy is discarded, so the global Gaussian representation doesn't change.
The main experiments run 50 adaptation steps per target view. Raising the number of adaptation steps improves PSNR and SSIM, but it also increases the per-view rendering cost. The authors settle on 50 steps because that setting balances reconstruction quality against rendering efficiency.
In the ablation on Dataset A, RAA gives the largest gain across PSNR, SSIM and LPIPS. Adding RAA lifts PSNR from 19.76 to 24.29 and SSIM from 0.5770 to 0.8330 over the version without it. The ablation in Tab. 2 covers only Dataset A.
Held-out slice results on two datasets
Dataset A holds real robotic lumbar spine scans from 63 healthy volunteers, and each scan contains over 3K frames. The default split feeds every fifth frame as input and scores frames at index 3 mod 5, which avoids near-duplicate tests. So the two splits answer different questions: real tracked scans on one side, controlled simulation on the other.
On Dataset A, UltraVoxelGS reaches PSNR 24.29 and SSIM 0.8329, the top values in Table 1. Its LPIPS of 0.2384 is the lowest in the table, compared to 0.3884 for 3DGS. The per-scene baselines fit every scene by optimization, so this comparison pits one forward pass against per-scene fitting.
On Dataset B, UltraVoxelGS reaches PSNR 20.87 and SSIM 0.3138, the highest values in the table. Its LPIPS of 0.6190 beats 3DGS at 0.6702 but is worse than the 0.5985 of UltraNeRF. So on simulated data the advantage shows up in PSNR and SSIM rather than in LPIPS.
To check 3D anatomy, the authors propagated an anchor mask with a frozen SAM2 and fused the masks along the poses on Dataset B. UltraVoxelGS reaches a 2D Dice of 0.8469 and a 3D Dice of 0.8787, versus 0.7441 and 0.8593 for 3DGS. Its 3D IoU of 0.7866 is the highest, compared to 0.7557 for 3DGS. The authors read this as closer shape agreement with the CT-derived liver reference.
Reconstruction time and per-view rendering cost
Reconstruction time is the other half of the speed claim, and Fig. 6 (a) plots it against PSNR on Dataset A. UltraVoxelGS takes 0.17 minutes per scene, compared to 10.00 minutes for 3DGS and 15.22 minutes for UltraGauss. Kernel interpolation is quicker at 0.02 minutes, but its PSNR in Table 1 sits far below the feed-forward result. The per-scene baselines ImplicitVol and UltraNeRF need 5.95 and 18.23 minutes on the same plot.
The headline claim cuts inference from 10-20 minutes to approximately 10 seconds, which the authors call over 35× faster. The speed comes from a feed-forward pass, so the model doesn't optimize each scene from scratch.
Render-time adaptation adds cost per view, so the second panel tracks rendering time per view against PSNR. That panel's x-axis runs from 0.0 to 3.5 seconds per single view. Render-time Appearance Adaptation freezes the geometry and updates only a transient copy of the appearance parameters for each target pose. More adaptation steps raise PSNR and SSIM, but each view takes longer to render.
The authors settle on 50 adaptation steps to balance reconstruction quality against rendering efficiency. Adapted values get discarded after each view, so the global reconstruction stays untouched.
The adaptation stage aims at sub-second latency for operator inspection. The authors point to a detailed runtime breakdown in Appendix B.1, which this section doesn't reproduce. The paper doesn't give render-time numbers beyond the step-count trade-off shown in the plot.
Scaling to long input sequences
The scalability test changes only the input sampling stride at reconstruction time, with no retraining of the model. Because the stride sets how many slices UltraVoxelGS receives, the test asks whether the same trained model still reconstructs well from much denser inputs. The authors report that UltraVoxelGS scales to over 1,000 input frames.
At a stride of 5×, about 600 frames raise the PSNR to 24.28 and the SSIM to 0.8329.
Denser inputs consistently improve reconstruction quality, so the model benefits from more posed slices instead of degrading. The memory cost barely grows, which fits the design where the voxel support has a fixed size and Gaussians are predicted only in local blocks. The authors read this as support for the local-to-global assembly on dense tracked sequences, since each local prediction stays tied to a target slice.
They didn't test sequences beyond the 2× stride setting in Table 3, so the 1,000-frame claim rests on this range.
What each component contributes
The Dataset A ablation starts from a plain interpolation row with PSNR 13.52, SSIM 0.3950 and LPIPS 0.5420. Turning on feed-forward voxel prediction alone moves PSNR only to 14.46, while SSIM drops to 0.3825. The authors say feed-forward voxel prediction remains limited without a Gaussian scene representation and ultrasound-aware rendering.
Adding DRA, which separates anisotropic reflection from cumulative attenuation, lifts PSNR to 19.76 and SSIM to 0.5770. With DRA in place, LPIPS falls to 0.5130 from the 0.5735 of the feed-forward-only row. Most of the PSNR gain in this table comes after the feed-forward step, from DRA and then RAA. RAA takes a nearby observed slice as an appearance anchor and updates only a transient copy of the appearance parameters.
Adding RAA raises PSNR from 19.76 to 24.29 and SSIM from 0.5770 to 0.8330.
Table 1 confirms the RAA effect on Dataset A: the variant without it reaches PSNR 19.76, against 24.29 for the full model. The adapted parameters are discarded after each target view, so the reconstructed global representation stays unchanged.

Figure 9 : Decoupled Reflection and Attenuation Rendering visualization on Dataset B. Note that the ground-truth attenuation maps are obtained from the simulation pipeline [32] and serve solely as a visual reference; no attenuation supervision is used during training. The red boxes highlight a structure that is present in the reflection component but becomes weak in the final ultrasound appearance due to cumulative attenuation.
Original paper · CC BY 4.0The authors also check whether the attenuation branch learns real structure, using simulator attenuation maps on Dataset B only as a visual reference. No attenuation supervision is used during training, so the attenuation branch gets no direct signal. The learned attenuation reaches a Pearson correlation of 0.6966 with the reference, against 0.6648 for a depth-linear decay fitted to it.
The gap is small, but the authors read it as evidence that the factorization captures attenuation structure without supervision.
Limitations: where gaps remain and what wasn't tested
UltraVoxelGS keeps only the structures that the observed evidence supports, so it doesn't fill those regions with plausible content. The authors treat this incompleteness as spatial feedback that marks where more scanning is needed, as Fig. 1 illustrates.
The main quantitative evaluation covers two datasets: 63 healthy volunteers in Dataset A and 100 simulated liver sequences in Dataset B. Dataset A contains lumbar spine scans, and Dataset B contains simulated liver sequences, so these comparisons cover only two anatomies. The two comparisons don't test other anatomies or other scanning protocols, so the reported gains don't yet carry over to them.
The handheld dataset appears only in Appendix D.2, outside the main experiments. The periodic reconstruction mode is described in Appendix E rather than in the main text.
The paper points to Appendix F for its full limitations, and that appendix isn't part of the main text. The conclusion expresses a hope that UltraVoxelGS can enable real-time spatial feedback during acquisition, which the paper doesn't measure. The experiments score held-out slice reconstruction after the sequence is processed, so live guidance during scanning wasn't evaluated.
Paper info
- Authors
- Wang, Yue, Chen, Haoxin, Guo, Xiaoqing
- Venue
- arXiv · Preprint
- First published
- 2026-11-9
- Added
- 2026-11-10
- Updated
- 2026-11-9
- Version
- v1
- arXiv
- 2611.11951
- Category
- cs.CV · eess.SP
- Original paper terms
- CC BY 4.0
- What we show
- Paper info, commentary and permitted figures from the original paper
AI commentary is a separate explanation from the original paper and may contain errors. The original paper and figures follow each source's terms of use and any rights noted separately.
Abstract
We present UltraVoxelGS, a 3D ultrasound reconstruction method that achieves both fast reconstruction and physically faithful rendering for the first time, bringing live spatial feedback during 2D ultrasound scanning within reach. This is made possible by a feed-forward design that predicts a complete Gaussian scene representation from posed ultrasound images directly, entirely bypassing the per-scene optimization bottleneck that has confined prior methods to offline use. Realising such feed-forward prediction in this setting is non-trivial: unlike natural images, ultrasound slices share at most one-dimensional intersections and exhibit view-dependent appearance due to acoustic propagation and attenuation, violating the dense overlap and photometric consistency assumed by existing feed-forward Gaussian methods. Hence, to achieve fast reconstruction, we introduce a feed-forward voxel-to-Gaussian pass that decouples representation size from input count by lifting all posed slices into a fixed-size voxel support and predicting Gaussian parameters directly. For faithful rendering, we propose ultrasound-aware appearance rendering strategy factorize reflection from cumulative attenuation during training and exploit appearance continuity among spatially adjacent slices for efficient Render-time Appearance Adaptation. On both real-world and simulated datasets, UltraVoxelGS achieves best PSNR/SSIM compared with per-scene optimization baselines while reducing inference from 10-20 minutes to approximately 10 seconds (over 35 times faster) and scales to sequences exceeding 1,000 frames. Code is available at https://github.com/YuebyYue/UltraVoxelGS-camera-ready.
Quote from the paper
Wang, Yue, Chen, Haoxin, Guo, Xiaoqing (2026). UltraVoxelGS: Voxel-First Feed-Forward Gaussian Splatting for 3D Ultrasound Reconstruction. arXiv:2611.11951v1. https://arxiv.org/abs/2611.11951v1
BibTeX
@misc{yue2026ultravoxelgs,
title = {{UltraVoxelGS: Voxel-First Feed-Forward Gaussian Splatting for 3D Ultrasound Reconstruction}},
author = {Wang, Yue and Chen, Haoxin and Guo, Xiaoqing},
year = {2026},
eprint = {2611.11951},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2611.11951v1}
}